May 2023
Hagit Hemi RN, Olga Morelli MD, Mordehay Vaturi MD, Ran Kornowski MD, Alexander Sagie MD, Yaron Shapira MD, Shmuel Schwartzenberg MD

Background: Cancellation of transesophageal echocardiography (TEE) tests leads to inefficient use of echocardiography laboratory (echo lab) time and wastes resources.

Objectives: To identify the causes of same-day TEE cancellations in hospitalized patients, to formulate a TEE order screening protocol, and to evaluate its efficacy at implementation.

Methods: We performed a prospective analysis of inpatients referred to a single tertiary hospital echo lab for TEE study by inpatient wards. A comprehensive screening protocol emphasizing active participation of all links directly involved in the chain of inpatient TEE referral was developed and implemented. Comparison of pre- and post-implementation of the new screening protocol on two consecutive periods of 6 months on TEE cancellation rates out of total ordered TEEs stratified by cause categories was performed.

Results: In total, 304 inpatient TEE procedures were ordered during the initial observation period; 54(17.8%) were canceled on the same day. The most common cancellation reasons were equally respiratory distress and patient not in fasted state (20.4% of total cancellations and 3.6% of all scheduled TEEs for each cause). Following implementation of the new screening process, total TEEs ordered (192) and cancelled (16) dropped significantly. A decrease in the rate of each cancellation category was observed, with statistical significance achieved for the overall cancellation rate (8.3% vs. 17.8%, P = 0.003), but not for the individual cancellation categories in split analysis.

Conclusions: A concerted effort to implement a comprehensive screening questionnaire significantly reduced same-day cancellations of scheduled TEEs.

May 2019
Shmuel Schwartzenberg MD, Ran Kornowski MD, Yaron Shapira MD, Abid Assali MD, Mordehay Vatury MD, Leor Perl MD, Hana Vaknin-Assa MD and Alexander Sagie MD

Background: The MitraClip procedure is becoming an acceptable alternative for high-risk patients with mitral regurgitation (MR) due to functional (FMR) or degenerative (DMR) disease and suitable mitral anatomy.

Objectives: To evaluate the results of MitraClip at our institute in carefully selected patients.

Methods: We conducted a retrospective analysis of medical records and echocardiography data from January 2012 to December 2017.

Results: A total of 39 MitraClip procedures in 37 patients (aged 75 ± 12 years, 9 women) was performed. Twenty-four patients presented with FMR, 12 with DMR, and 1 with combined pathology. One-day post-procedure MR was moderate to low in 86.1% of patients, with immediate device success in 88.8%. MR at 1 year was moderate to low in 79% at 1 year. Survival at 1 year was 86% and at 2 years 69.4%. Peri-procedural (< 1 week) death and MitraClip failure occurred in one and three patients, respectively. New York Heart Association score improved to class 1 or 2 in 37% of patients at 1 year vs. one patient at baseline. Post-procedural systolic pulmonary pressure was reduced from 53 (range 48–65) to 43 (range 36–52) mmHg at 1 month with a subsequent plateau at follow-up, to 41 (34–57) mmHg at 6 months, and to 47 (38–50) at 12 months.

Conclusions: MitraClip in severe MR resulted in modest improvement in functional status and pulmonary pressure with a small risk of immediate procedural complications. Outcomes are encouraging considering the natural course of MR and the risks of surgical intervention.

March 2017
Uri Landes MD, Arthur Kerner MD, Amit Segev MD, Haim Danenberg MD, Yaron Shapira MD, Ariel Finkelstein MD and Ran Kornowski MD FESC FACC

Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery. 

Objectives: To report the multicenter TVIV experience in Israel.

Methods: We approached multiple centers and collected data regarding seven TVIV cases. 

Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up. 

Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk. 

 