IMAJ | volume 25
Journal 5, May 2023
pages: 324-327
1 Department of Cardiology, Rabin Medical Center (Beilinson Campus), Petah Tikva, Israel
2 Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
Summary
Background:
Cancellation of transesophageal echocardiography (TEE) tests leads to inefficient use of echocardiography laboratory (echo lab) time and wastes resources.
Objectives:
To identify the causes of same-day TEE cancellations in hospitalized patients, to formulate a TEE order screening protocol, and to evaluate its efficacy at implementation.
Methods:
We performed a prospective analysis of inpatients referred to a single tertiary hospital echo lab for TEE study by inpatient wards. A comprehensive screening protocol emphasizing active participation of all links directly involved in the chain of inpatient TEE referral was developed and implemented. Comparison of pre- and post-implementation of the new screening protocol on two consecutive periods of 6 months on TEE cancellation rates out of total ordered TEEs stratified by cause categories was performed.
Results:
In total, 304 inpatient TEE procedures were ordered during the initial observation period; 54(17.8%) were canceled on the same day. The most common cancellation reasons were equally respiratory distress and patient not in fasted state (20.4% of total cancellations and 3.6% of all scheduled TEEs for each cause). Following implementation of the new screening process, total TEEs ordered (192) and cancelled (16) dropped significantly. A decrease in the rate of each cancellation category was observed, with statistical significance achieved for the overall cancellation rate (8.3% vs. 17.8%,
P = 0.003), but not for the individual cancellation categories in split analysis.
Conclusions:
A concerted effort to implement a comprehensive screening questionnaire significantly reduced same-day cancellations of scheduled TEEs.