May 2023
Hagit Hemi RN, Olga Morelli MD, Mordehay Vaturi MD, Ran Kornowski MD, Alexander Sagie MD, Yaron Shapira MD, Shmuel Schwartzenberg MD

Background: Cancellation of transesophageal echocardiography (TEE) tests leads to inefficient use of echocardiography laboratory (echo lab) time and wastes resources.

Objectives: To identify the causes of same-day TEE cancellations in hospitalized patients, to formulate a TEE order screening protocol, and to evaluate its efficacy at implementation.

Methods: We performed a prospective analysis of inpatients referred to a single tertiary hospital echo lab for TEE study by inpatient wards. A comprehensive screening protocol emphasizing active participation of all links directly involved in the chain of inpatient TEE referral was developed and implemented. Comparison of pre- and post-implementation of the new screening protocol on two consecutive periods of 6 months on TEE cancellation rates out of total ordered TEEs stratified by cause categories was performed.

Results: In total, 304 inpatient TEE procedures were ordered during the initial observation period; 54(17.8%) were canceled on the same day. The most common cancellation reasons were equally respiratory distress and patient not in fasted state (20.4% of total cancellations and 3.6% of all scheduled TEEs for each cause). Following implementation of the new screening process, total TEEs ordered (192) and cancelled (16) dropped significantly. A decrease in the rate of each cancellation category was observed, with statistical significance achieved for the overall cancellation rate (8.3% vs. 17.8%, P = 0.003), but not for the individual cancellation categories in split analysis.

Conclusions: A concerted effort to implement a comprehensive screening questionnaire significantly reduced same-day cancellations of scheduled TEEs.

Marina Leitman MD FESC, Isabella Pilcha MD, Vladimir Tyomkin MSc, Zoe Haitov MD

Background: Traditionally, transesophageal echocardiography (TEE) has been performed under moderate sedation and local pharyngeal anesthesia. Respiratory complications during the TEE can occur.

Objectives: To test the effectiveness of low-dose midazolam combined with verbal sedation during TEE.

Methods: The study comprised 157 consecutive patients who underwent TEE under mild conscious sedation. All patients received local pharyngeal anesthesia and low doses of midazolam combined with verbal sedation. The course of TEE and clinical characteristics of the patients were analyzed.

Results: The mean age was 64 ± 15.3 years, 96 males (61%). In 6% of the patients, low dose midazolam in combination with verbal sedation was insufficient and propofol was administrated. In women under 65 years of age with normal renal function, there was a 40% risk of low-dose midazolam being ineffective (P = 0.0018).

Conclusions: In most patients, TEE can be conducted easily using low-dose midazolam combined with verbal sedation. Some patients need deeper sedation with anesthetic agents like propofol. These patients tended to be younger, in good general health, and more often female.

April 2007
Y. Shapira, D. E. Weisenberg, M. Vaturi, E. Sharoni, E. Raanani, G. Sahar, B. A. Vidne, A. Battler and A. Sagie

Backgound: The use of intraoperative transesophageal echocardiogram in patients with infective endocarditis is usually reserved for cases of inadequate preoperative testing or suspected extension to perivalvular tissue.

Objectives: To explore the impact of routine intraoperative TEE[1] in patients with infective endocarditis.

Methods: The impact of intraoperative TEE on the operative plan, anatomic-physiologic results, and hemodynamic assessment or de-airing was analyzed in 59 patients (38 males, 21 females, mean age 57.7 ± 16.8 years, range 20–82) operated for active infective endocarditis over 56 months.

Results: Immediate pre-pump echocardiography was available in 52 operations (86.7%), and changed the operative plan in 6 of them (11.5%). Immediate post-pump study was available in 59 patients (98.3%) and accounted for second pump-run in 6 (10.2%): perivalvular leak (3 cases), and immobilized leaflet, significant mitral regurgitation following vegetectomy, and failing right ventricle requiring addition of vein graft (1 case each). Prolonged de-airing was necessary in 6 patients (10.2%). In 5 patients (8.5%) the postoperative study aided in the evaluation and treatment of difficult weaning from the cardiopulmonary bypass pump. In 21 patients (35.6%) the application of intraoperative TEE affected at least one of the four pre-specified parameters.
Conclusions: Intraoperative TEE has an important role in surgery for infective endocarditis and should be routinely implemented







[1] TEE = transesophageal echocardiogram


June 2001
March 2001
Marina Leitman, MD, Eli Peleg, MD, Simcha Rosenblat, MD, Eddy Sucher, MD, Ruthie Wolf, Stanislav Sedanko, Ricardo Krakover, MD and Zvi Vered, MD
January 2000
Alexander Tenenbaum MD PhD, Alexander Garniek MD, Joseph Shemesh MD, Chaim I. Stroh MD, Yacov Itzchak MD PhD, Zvi Vered MD, Michael Motro MD and Enrique Z. Fisman MD

Background: Protruding aortic atheromas are a potential source of stroke and systemic emboli. The single modality currently available for their detection has been transesophageal echocardiography. However, TEE does not allow full visualization of the upper part of the ascending aorta and proximal aortic arch.

Objectives: To investigate whether double helical computerized tomography- both with and without contrast injection - may represent a useful technique for noninvasive detection of PAA in stroke patients.

Methods: Forty consecutive patients ≥50 years of age who sustained a recent ischemic stroke and/or systemic emboli (within 15 days after the onset of the event) were enrolled in the study and underwent TEE and DHCT without contrast injection using thin slice acquisition (3.2 mm thickness and 1.5 mm reconstruction increment). In addition, the last eight consecutive patients, after obtaining an unenhanced scan, underwent a contrast-enhanced DHCT following peripheral intravenous injection of a small amount of contrast material (15 ml of diatrizoate).

Results: PAAs were demonstrated by TEE in 18 patients (45%); in 16 of them (89%) the atheromas were recognized by DHCT. Of the 22 patients without PAA on TEE, DHCT confirmed their absence in 18 (82%). DHCT yielded a sensitivity of 89%, a specificity of 82%, and an overall accuracy of 85%. The total number of protruding plaques detected by TEE was 43, of which 41 (95%) were correctly identified by DHCT. The mean thickness of the plaques was 5.6±2.4 mm on TEE, and 5.4±2.3 on DHCT (P=NS), with a good correlation between the modalities (γ=0.84). Contrast-enhanced DHCT scans demonstrated absolute equivalence to TEE in aortic areas defined as "clearly visualized by TEE." DHCT detected PAA between the distal ascending aorta and the proximal arch in seven patients; these atheromas were not included in the comparative analysis. In these "occult" areas, DHCT may be superior to TEE.

Conclusions: DHCT without contrast injection using thin slice acquisition may become a useful modality for rapid noninvasive detection of PAA. Contrast-enhanced DHCT scans significantly improve imaging quality and may be superior to TEE in the upper ascending aorta and the proximal arch (areas not well visualized by TEE).

 

__________________________________

 

TEE= transesophgeal echocardiography

PAA= protruding aortic atheroma

DHCT= dual helical computerized tomography
 