February 2020
March 2017
Uri Landes MD, Arthur Kerner MD, Amit Segev MD, Haim Danenberg MD, Yaron Shapira MD, Ariel Finkelstein MD and Ran Kornowski MD FESC FACC

Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery. 

Objectives: To report the multicenter TVIV experience in Israel.

Methods: We approached multiple centers and collected data regarding seven TVIV cases. 

Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up. 

Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk. 

 

January 2016
Eyal R. Nachum MD, Ehud Raanani MD, Amit Segev MD, Victor Guetta MD, Ilan Hai MD, Amihai Shinfeld MD, Paul Fefer MD, Hamdan Ashraf MD, Israel Barabash MD, Amjad Shalabi MD and Dan Spiegelstein MD

Background: The rate of mitral bioprosthesis implantation in clinical practice is increasing. Transcatheter valve-in-valve implantation has been described for high risk patients requiring redo valve surgery. 

Objectives: To report our experience with transapical valve-in-valve implantation for failed mitral bioprosthesis.

Methods: Since 2010, 10 patients have undergone transapical valve-in-valve implantation for failed bioprosthesis in our center. Aortic valve-in-valve implantation was performed in one of them and mitral valve-in-valve implantation in nine. Mean age was 82 ± 4 years and 6 were female (67%). Mean time from original mitral valve (MV) replacement to valve-in-valve procedure was 10.5 ± 3.7 years. Follow-up was completed by all patients with a mean duration of 13 ± 12 months. 

Results: Preoperatively, all patients presented with significant mitral regurgitation; two with mitral stenosis due to structural valve failure. All nine patients underwent successful transapical valve-in-valve implantation with an Edwards Sapien™ balloon expandable valve. There was no in-hospital mortality. Mean and median hospital duration was 15 ± 18 and 7 days respectively. Valve implantation was successful in all patients and there were no major complications, except for major femoral access bleeding in one patient. At last follow-up, all patients were alive and in NYHA functional class I or II. Echocardiography follow-up demonstrated that mitral regurgitation was absent or trivial in seven patients and mild in two. At follow-up, peak and mean gradients changed from 26 ± 4 and 8 ± 2 at baseline to 16.7 ± 3 and 7.3 ± 1.5, respectively.

Conclusions: Transcatheter transapical mitral valve-in-valve implantation for failed bioprosthesis is feasible in selected high risk patients. Our early experience with this strategy is encouraging. Larger randomized trials with long-term clinical and echocardiographic follow-up are recommended.

 

September 2013
A. L. Schwartz, Y. Topilsky, G. Uretzky, N. Nesher, Y. Ben-Gal, S. Biner, G. Keren and A. Kramer

Background: Stentless aortic bioprostheses were designed to provide improved hemodynamic performance and potentially better survival.

Objectives: To report the outcomes of patients after aortic valve replacement with the Freestyle® stentless bioprosthesis in the Tel Aviv Medical Center followed for ≤ 15 years.

Methods and Results: Between 1997 and 2011, 268 patients underwent primary aortic valve replacement with a Freestyle bioprosthesis, 211 (79%) of them in the sub-coronary position. Mean age, Charlson comorbidity index and Euro-score were 71.0 ± 9.2 years, 4.2 ± 1.5 and 10.2 ± 11 respectively, and 156 (58%) were male. Peak and mean trans-aortic gradient decreased significantly (75.0 ± 29.1 vs. 22.8 ± 9.6 mmHg, P < 0.0001; and 43.4 ± 17.2 vs. 12.1 ± 5.4 mmHg, P < 0.0001 respectively) in 3 months of follow-up. Mean overall follow-up was 4.9 ± 3.1 years and was complete in all patients. In-hospital mortality was 4.1% (n=11) but differed significantly between the first 100 patients operated before 2006 and the last 168 patients operated after January 2006 (8 vs. 3 patients, 8.0% vs. 1.8%, P = 0.01). Overall, 5 and 10 year survival rates were 85 ± 2.5% and 57.2 ± 5.7%, respectively. Five year survival was markedly improved in patients operated after January 2006 compared to those operated in the early years of the experience (92.3 ± 2.3% vs. 76.0 ± 4.4%, P = 0.0009). All the 21 octogenarians operated after January 2006 survived surgery, with excellent 5 year survival (85.1 ± 7.9%). Six patients required reoperation during follow-up: structural valve deterioration in five and endocarditis in one.

Conclusions: Aortic valve replacement with the Freestyle bioprosthesis provides good long-term hemodynamic and clinical outcomes, even in octogenarians. Valve calcification is the major (and rare) mode of valve deterioration leading to reoperation in these patients. 

D. Guttman, A. Mizrachi, T. Hadar, G. Bachar, Y. Hamzani, S. Marx and J. Shvero
 Background: Voice restoration following total laryngectomy is an important part of patients’ rehabilitation and long-term quality of life.

Objectives: To evaluate the long-term outcome of indwelling voice prostheses inserted during (primary procedure) or after (secondary procedure) total laryngectomy.

Methods: The study group included 90 patients who underwent total laryngectomy and tracheoesophageal puncture (TEP) with placement of voice prosthesis at a tertiary medical center during the period 1990–2008. Background, clinical and outcome data were collected by medical file review. Findings were compared between patients in whom TEP was performed as a primary or a secondary procedure.

Results: TEP was performed as a primary procedure in 64 patients and a secondary procedure in 26. Corresponding rates of satisfactory voice rehabilitation were 84.4% and 88.5% respectively. There was no association of voice quality with either receipt of adjuvant radiation/chemoradiation or patient age. The average lifetime of the voice prosthesis was 4.2 months for primary TEP and 9.06 months for secondary TEP (p = 0.025).

Conclusions: Primary TEP provides almost immediate and satisfactory voice rehabilitation. However, it is associated with a significantly shorter average prosthesis lifetime than secondary TEP. Chemoradiotherapy and patient age do not affect voice quality with either procedure.

May 2009
S. Heller, I. Fenichel, M. Salai, T Luria and S. Velkes

Background: Unicompartmental knee replacement has become a surgical alternative for treating isolated medial or lateral osteoarthritis of the knee or avascular necrosis of the femoral condyls.

Objectives: To evaluate the short-term results of the Oxford Phase 3® unicompartmental knee replacement for unicompartmental knee arthrosis or avascular necrosis of the medial

femoral condyle.

Methods: During the period 2003–2005 a total of 59 patients (59 knees) underwent medial Oxford Phase 3® unicompartmental knee replacement in our unit. The patients were interviewed and examined, and standing anteroposterior and lateral X-rays were taken. All patients completed the Western Ontario and McMaster Universities Index of Osteoarthritis and the Short Form 12 questionnaire, and the International Knee Society score was evaluated. The data were collected and statistical analysis was performed.

Results: X-rays were performed and scores for the WOMAC[1] and IKS[2] were assessed for 42 patients (31 females, 11 males). At an average of 32 months after surgery, the total WOMAC score was 30. The mean SF[3]12 physical score was 38 and the mean SF12 mental score was 51. The mean IKS score was 166. Ninety-one percent of the patients had active flexion of 120 degrees or more. Of 59 knees 7 were converted to total knee arthroplasty – all of them within the first 2 years of starting the procedure and all of them in relatively young patients.

Conclusions: Despite the higher revision rate to TKR[4] in this study, our findings confirm the short-term results reported in other studies of the Oxford medial unicompartmental knee and our early failure rate could be explained by a performance learning curve. This study confirms that this bone-preserving procedure should be considered in end-stage isolated unicompartmental osteoarthritis or avascular necrosis by surgeons who have the adequate training and experience.






[1] WOMAC = Western Ontario and McMaster Universities Index of Osteoarthritis

[2] IKS = International Knee Society

[3] SF = short form

[4] TKR = total knee arthroplasty

 


January 2003
I. Caspi, M. Levinkopf and J. Nerubay

Background: Damage to the intervertebral disk is usually corrected by means of a prosthesis.

Objectives: To report the outcome of the artificial lumbar disk replacement with the Charité SB III disk prosthesis in 20 patients after a 48 month follow-up.

Methods: The 20 patients were evaluated clinically and radiographically during this period. Preoperative diagnosis included degenerative diskopathy in 17 patients and failed posterior conventional diskectomy in 3. The prosthesis was implanted at one level in 17 patients and bi-level implantation was performed in the other 3 patients.

Results: Eighty percent of patients reported satisfactory to very good results. Poor results were reported by four patients, one of whom underwent posterolateral fusion and another is waiting for the same operation. There were two dislocations of the prosthesis followed by immediate revision surgery.

Conclusions: Contraindications for surgery appear to be the principal cause of failure rather than the prosthesis itself.
 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel