• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


February 2016
Amjad Shalabi MD, Ehud Raanani MD, Amihai Shinfeld MD, Rafael Kuperstein MD, Alexander Kogan MD, Alexander Lipey MD, Eyal Nachum MD and Dan Spiegelstein MD

Background: Prolonged life expectancy has increased the number of elderly high risk patients referred for surgical aortic valve replacement (AVR). These referred high risk patients may benefit from sutureless bioprosthesis procedures which reduce mortality and morbidity.

Objectives: To present our initial experience with sutureless aortic bioprotheses, including clinical and echocardiographic results, in elderly high risk patients referred for AVR. 

Methods: Forty patients (15 males, mean age 78 ± 7 years) with symptomatic severe aortic stenosis underwent AVR with the 3F Enable™ or Perceval™ sutureless bioprosthesis during the period December 2012 to May 2014. Mean logistic EuroScore was 10 ± 3%. Echocardiography was performed preoperatively, intraoperatively, at discharge and at follow-up.

Results: There was no in-hospital mortality. Nine patients (22%) underwent minimally invasive AVR via a right anterior mini-thoracotomy and one patient via a J-incision. Four patients underwent concomitant coronary aortic bypass graft, two needed intraoperative repositioning of the valve, one underwent valve exchange due to inappropriate sizing, three (7.5%) had a perioperative stroke with complete resolution of neurologic symptoms, and one patient (2.5%) required permanent pacemaker implantation due to complete atrioventricular block. Mean preoperative and postoperative gradients were 44 ± 14 and 13 ± 5 mmHg, respectively. At follow-up, 82% of patients were in New York Heart Association functional class I and II.

Conclusions: Sutureless AVR can be used safely in elderly high risk patients with relatively low morbidity and mortality. The device can be safely implanted via a minimally invasive incision. Mid-term hemodynamic results are satisfactory, demonstrating significant clinical improvement.

 

December 2015
Orly Goitein MD, Elio Di Segni MD, Yael Eshet MD, Victor Guetta MD, Amit Segev MD, Eyal Nahum MD, Ehud Raanani MD, Eli Konen MD and Ashraf Hamdan MD

Background: Trans-catheter valve implantation (TAVI) is a non-surgical alternative for patients with severe aortic stenosis (AS). Pre-procedural computed tomography angiography (CTA) allows accurate “road mapping,” aortic annulus sizing and the detection of incidental findings.

Objectives: To document the prevalence of non-valvular extra-cardiac findings on CTA prior to TAVI and the impact of these findings on the procedure.  

Methods: Ninety AS patients underwent CTA as part of pre-TAVI planning. Scans extended from the clavicles to the groin. Non-vascular non-valvular findings were documented and graded as follows: (A) significant findings causing TAVI cancellation or postponement, (B) significant findings leading to a change in the TAVI procedure approach, (C) non-significant findings not affecting the TAVI procedure. 

Results: TAVI was planned for 90 patients; their average age was 80.2 ± 7.5 years, 53% were females. Overall, non-valvular cardiac, extra-cardiac and extra-vascular significant and non-significant incidental findings were documented in 97% of scans (87/90). Significant pathologies causing TAVI cancellation or postponement (category A) were documented in 8%. Significant findings affecting the TAVI procedure (category B) were found in 16% of patients. 

Conclusions: Pre-TAVI CTA detected non-valvular extra-vascular pathologies leading to procedure cancellation/postponement or procedure modification in 8% and 16%, respectively. Comprehensive CTA evaluation that acknowledges the importance of such findings is of major importance since it might alter the TAVI procedure or even render it inappropriate. 

 

October 2015
July 2015
Smadar Eventov-Friedman MD PhD, Ayala Frumkin PhD, Benjamin Bar-Oz MD and Annick Raas-Rothschild MD
October 2013
A. Finkelstein, E.Y. Birati, Y. Abramowitz, A. Steinvil, N. Sheinberg, S. Biner, S. Bazan, Y. Ben Gal, A. Halkin, Y. Arbel, E. Ben-Assa, E. Leshem-Rubinow, G. Keren and S. Banai
 Background: Transcatheter aortic valve implantation (TAVI) has recently become an alternative to surgical aortic valve replacement in selected patients with high operative risk.

Objectives: To investigate the 30 day clinical outcome of the first 300 consecutive patients treated with transfemoral TAVI at the Tel Aviv Medical Center.

Methods: The CoreValve was used in 250 patients and the Edwards-Sapien valve in 50 patients. The mean age of the patients was 83 ± 5.3 years (range 63–98 years) and the mean valve area 0.69 ± 0.18 cm2 (range 0.3–0.9 cm2); 62% were women.

Results: The procedural success rate was 100%, and 30 day follow-up was done in all the patients. The average Euro-score for the cohort was 26 ± 13 (range 1.5–67). Total in-hospital mortality and 30 day mortality were both 2.3% (7 patients). Sixty-seven patients (22%) underwent permanent pacemaker implantation after the TAVI procedure, mostly due to new onset of left bundle brunch block and prolonged PR interval or to high degree atrioventricular block. The rate of stroke was 1.7% (5 patients). Forty-one patients (13.7%) had vascular complications, of whom 9 (3%) were defined as major vascular complications (according to the VARC definition).

Conclusions: The 30 day clinical outcome in the first 300 consecutive TAVI patients in our center was favorable, with a mortality rate of 2.3% and low rates of stroke (1.7%) and major vascular complications (3%).

 

 







 VARC = Valve Academic Research Consortium


September 2013
A. L. Schwartz, Y. Topilsky, G. Uretzky, N. Nesher, Y. Ben-Gal, S. Biner, G. Keren and A. Kramer

Background: Stentless aortic bioprostheses were designed to provide improved hemodynamic performance and potentially better survival.

Objectives: To report the outcomes of patients after aortic valve replacement with the Freestyle® stentless bioprosthesis in the Tel Aviv Medical Center followed for ≤ 15 years.

Methods and Results: Between 1997 and 2011, 268 patients underwent primary aortic valve replacement with a Freestyle bioprosthesis, 211 (79%) of them in the sub-coronary position. Mean age, Charlson comorbidity index and Euro-score were 71.0 ± 9.2 years, 4.2 ± 1.5 and 10.2 ± 11 respectively, and 156 (58%) were male. Peak and mean trans-aortic gradient decreased significantly (75.0 ± 29.1 vs. 22.8 ± 9.6 mmHg, P < 0.0001; and 43.4 ± 17.2 vs. 12.1 ± 5.4 mmHg, P < 0.0001 respectively) in 3 months of follow-up. Mean overall follow-up was 4.9 ± 3.1 years and was complete in all patients. In-hospital mortality was 4.1% (n=11) but differed significantly between the first 100 patients operated before 2006 and the last 168 patients operated after January 2006 (8 vs. 3 patients, 8.0% vs. 1.8%, P = 0.01). Overall, 5 and 10 year survival rates were 85 ± 2.5% and 57.2 ± 5.7%, respectively. Five year survival was markedly improved in patients operated after January 2006 compared to those operated in the early years of the experience (92.3 ± 2.3% vs. 76.0 ± 4.4%, P = 0.0009). All the 21 octogenarians operated after January 2006 survived surgery, with excellent 5 year survival (85.1 ± 7.9%). Six patients required reoperation during follow-up: structural valve deterioration in five and endocarditis in one.

Conclusions: Aortic valve replacement with the Freestyle bioprosthesis provides good long-term hemodynamic and clinical outcomes, even in octogenarians. Valve calcification is the major (and rare) mode of valve deterioration leading to reoperation in these patients. 

S. Schwartzenberg, V. Meledin, L. Zilberman, S. Goland, J. George and S. Shimoni

Background: The pathophysiology of aortic stenosis (AS) involves inflammatory features including infiltration of the aortic valve (AV) by activated macrophages and T cells, deposition of lipids, and heterotopic calcification.

Objectives: To evaluate the correlation between white blood cell (WBC) differential count and the occurrence and progression of AS.

Methods: We identified in our institutional registry 150 patients with AS who underwent two repeated echo studies at least 6 months apart. We evaluated the association between the average of repeated WBC differential counts sampled during the previous 3 years and subsequent echocardiographic AS indices.

Results: There was no significant difference in total WBC, lymphocyte or eosinophil count among mild, moderate or severe AS groups. There was a progressive decrease in monocyte count with increasing AS severity (P = 0.046), more prominent when comparing the mild and severe groups. There was a negative correlation between AV peak velocity or peak or mean gradient and monocyte count in the entire group (r = -0.31, -0.24, and -0.25 respectively, all P ≤ 0.01). Similar partial correlations controlling for age, gender, hypertension, smoking, dyslipidemia and ejection fraction remained significant. The median changes over time in peak velocity and peak gradients in AS patients were 0.44 (0–1.3) m/sec/year and 12 (0–39) mmHg/year, respectively. There was no correlation between any of the WBC differential counts and the change in peak velocity or peak gradient per year.

Conclusions: Severe AS is associated with decreased total monocyte count. These findings may provide further clues to the mechanism underlying the pathogenesis of aortic stenosis.

August 2013
A. Segev, D. Spiegelstein, P. Fefer, A. Shinfeld, I. Hay, E. Raanani and V. Guetta

Background: Trans-catheter aortic valve implantation (TAVI) has emerged as a novel therapeutic approach for patients with severe tricuspid aortic stenosis (AS) not suitable for aortic valve replacement.

Objectives: To describe our initial single-center experience with TAVI in patients with "off-label" indications.

Methods: Between August 2008 and December 2011 we performed TAVI in 186 patients using trans-femoral, trans-axillary, trans-apical and trans-aortic approaches. In 11 patients (5.9%) TAVI was undertaken due to: a) pure severe aortic regurgitation (AR) (n=2), b) prosthetic aortic valve (AV) failure (n=5), c) bicuspid AV stenosis (n=2), and d) prosthetic valve severe mitral regurgitation (MR) (n=2).

Results: Implantation was successful in all: six patients received a CoreValve and five patients an Edwards-Sapien valve. In-hospital mortality was 0%. Valve hemodynamics and function were excellent in all patients except for one who received an Edwards-Sapien that was inside a Mitroflow prosthetic AV and led to consistently high trans-aortic gradients. No significant residual regurgitation in AR and MR cases was observed.
Conclusions: TAVI is a good alternative to surgical AV replacement in high risk or inoperable patients with severe AS. TAVI for non-classical indications such as pure AR, bicuspid AV, and failed prosthetic aortic and mitral valves is feasible and safe and may be considered in selected patients. 

July 2013
N. Roguin Maor
 Background: Smoking is a serious health issue worldwide. Smoking trends among physicians predict similar trends in the general population. Little is known about current smoking rates among physicians.

Objectives: To investigate current smoking trends among Israeli physicians.

Methods: All practicing physicians at a tertiary university-affiliated medical center in central Israel were invited to complete a Web-based questionnaire on smoking habits and smoking-related issues via the institutional email. Findings were compared to those in the general population and between subgroups.

Results: Of the 90 responders (53 male, 88 Jewish), 54 (60%) had never smoked, 21 (23.3%) were past smokers, and 15 (16.7%) were current smokers. The rate of current smokers was lower than in the general population. The proportion of current smokers was higher among residents than attending physicians and among physicians in surgical compared to medical specialties. Past smokers accounted for 17.9% of the residents (average age at quitting 26.2 years) and 28.1% of the attending physicians (average age at quitting 33.0 years). Non-smokers more frequently supported harsh anti-smoking legislation.

Conclusions: The rate of smoking is lower in physicians than in the general population but has not changed over the last 15 years. Anti-smoking programs should particularly target physicians in surgical specialties. 

October 2012
Y. Turgeman, A. Feldman, K. Suleiman, L.I. Bushari, I. Lavi and L. Bloch

Background: Understanding the mechanism and the main components involved in rheumatic mitral regurgitation (MR) associated with dominant pliable mitral stenosis (MS) may improve our ability to repair some mixed rheumatic mitral valve pathologies.

Objectives: To assess mitral valve structural components in pure mitral stenosis versus mitral stenosis associated with mild regurgitation

Methods: Using two-dimensional echocardiography, we performed mitral valve structural analysis in two groups of patients prior to balloon mitral valvuloplasty (BMV). The first group, consisting of 13 females and 2 males (mean age 39 ± 5 years), suffered from pure pliable mitral stenosis (PPMS), while the second group, with 22 females and 2 males (mean age 44 ± 5 years), had mixed mitral valve disease (MMVD) characterized by mild MR in the presence of dominant pliable MS. All echocardiographic measurements relating to the mechanism of MR were undertaken during the systolic phase.

Results: The mean Wilkins scores of the PPMS and MMVD groups were 7 ± 1 and 8 ± 1 respectively (P = 0.004). No significant differences were found between the MMVD group and the PPMS group regarding annular circumference (15.5 ± 1.4 cm vs. 15.4 ± 1.6 cm, P = 0.84), annular diameter (36 ± 4 mm vs. 38 ± 5 mm, P = 0.18), and chordae tendinae length directed to the anterior mitral leaflet (AML) (10 ± 2 mm vs. 11 ± 2 mm, P = 0.137). However, anterior vs. posterior mitral leaflet length during systole was significantly lower in the MMVD than in the PPMS group (2.2 ± 0.5 vs. 2.8 ± 0.4, P = 0.02), whereas the AML thickness at the co-aptation point was greater in the MMVD than in the PPMS group (7 ± 1 vs. 5 ± 1 mm, P = 0.0004).

Conclusions: In rheumatic valves, thickening and shortening of the AML are the main factors determining the appearance of mild MR in the presence of dominant pliable MS.

October 2011
T. Wolak, A. Belkin, V. Ginsburg, G. Greenberg, O. Mayzler, A. Bolotin, E. Paran and G. Szendro

Background: Percutaneous angioplasty (PTA) and stenting is an established procedure for the treatment of hypertension caused by atherosclerotic renal artery stenosis. However recently, the decision whether or not to perform this procedure has raised considerable debate.

Objectives: To examine the association between the basic clinical and radiological characteristics of candidates for renal artery PTA and the clinical outcome of the procedure in terms of improvement of blood pressure control and renal function.

Methods: We conducted a retrospective cohort study of all patients who underwent percutaneous transluminal renal artery angioplasty (PTRA) and stent implantation in a tertiary medical center during the period 2000–2007. The clinical and radiological data were extracted from the medical file of each patient. Blood pressure measurements and creatinine level were recorded before the procedure and 1 month, 6 months, 12 months and 18 months after PTRA.

Results: Thirty-two patients were included in the final statistical analysis. The mean age of the study population was 66.6 ± 8.8 years old and 75% were men. There was a significant reduction in both systolic and diastolic blood pressure 1 month after the procedure: 160.5 ± 24.7 vs. 141.8 ± 23.6 mmHg and 83.8 ± 12.9 vs. 68.8 ± 11.8 mmHg respectively (P < 0.001). The reduction in blood pressure was constant throughout the follow-up period and was evident 18 months after the procedure: 160.5 ± 24.7 vs. 135.0 ± 35.1 mmHg and 83.8 ± 12.9 vs. 71.3 ± 16.5 mmHg respectively (P < 0.001). However, no improvement in renal function was observed at any time during the follow-up period. We could not demonstrate an association between clinical or radiological features and the clinical outcome after PTRA.

Conclusions: Our findings show that PTRA[1] can be considered an effective procedure for improving blood pressure control in patients with atherosclerotic renal artery stenosis (ARAS) and resistant hypertension. This research, together with previous studies, strengthens the knowledge that the decline in glomerular filtration rate seen in many patients with ARAS is non-reversible and is not improved by PTRA.






[1] PTRA = percutaneous transluminal renal artery angioplasty


September 2010
D. Mutlak, D. Aronson, J. Lessick, S.A. Reisner, S. Dabbah and Y. Agmon

Background: Trans-aortic pressure gradient in patients with aortic stenosis and left ventricular systolic dysfunction is typically low but occasionally high.

Objectives: To examine the distribution of trans-aortic PG[1] in patients with severe AS[2] and severe LV[3] dysfunction and compare the clinical and echocardiographic characteristics and outcome of patients with high versus low PG.

Methods: Using the echocardiographic laboratory database at our institution, 72 patients with severe AS (aortic valve area ≤ 1.0 cm2) and severe LV dysfunction (LV ejection fraction ≤ 30%) were identified. The characteristics and outcome of these patients were compared.

Results: PG was high (mean PG ≥ 35 mmHg) in 32 patients (44.4%) and low (< 35 mmHg) in 40 (55.6%). Aortic valve area was slightly smaller in patients with high PG (0.63 ± 0.15 vs. 0.75 ± 0.16 cm2 in patients with low PG, P = 0.003), and LV ejection fraction was slightly higher in patients with high PG (26 ± 5 vs. 22 ± 5% in patients with low PG, P = 0.005). During a median follow-up period of 9 months 14 patients (19%) underwent aortic valve replacement and 46 patients (64%) died. Aortic valve replacement was associated with lower mortality (age and gender-adjusted hazard ratio 0.19, 95% confidence interval 0.05–0.82), whereas trans-aortic PG was not (P = 0.41).

Conclusions: A large proportion of patients with severe AS have relatively high trans-aortic PG despite severe LV dysfunction, a finding partially related to more severe AS and better LV function. Trans-aortic PG is not related to outcome in these patients.






[1] PG = pressure gradient



[2] AAS = aortic stenosis



[3] LV = left ventricular


August 2010
H. Danenberg, A. Finkelstein, R. Kornowski, A. Segev, D. Dvir, D. Gilon, G. Keren, A. Sagie, M. Feinberg, E. Schwammenthal, S. Banai, C. Lotan and V. Guetta

Background: The prevalence of aortic stenosis increases with advancing age. Once symptoms occur the prognosis in patients with severe aortic stenosis is poor. The current and recommended treatment of choice for these patients is surgical aortic valve replacement. However, many patients, mainly the very elderly and those with major comorbidities, are considered to be at high surgical risk and are therefore denied treatment. Recently, a transcatheter alternative to surgical AVR[1] has emerged.

Objectives: To describe the first year experience and 30 day outcome of transcatheter aortic self-expandable CoreValve implantation in Israel.

Methods: Transcatheter aortic valve implantation using the CoreValve system has been performed in Israel since September 2008. In the following year 55 patients underwent CoreValve TAVI[2] in four Israeli centers.

Results: Patients' mean age was 81.7 ± 7.1 years; there were 35 females and 20 males. The mean valve area by echocardiogram was 0.63 ± 0.16 cm2. The calculated mean logistic Euroscore was 19.3 ± 8%. Following TAVI, mean transvalvular gradient decreased from baseline levels of 51 ± 13 to 9 ± 3 mmHg. The rate of procedural success was 98%. One patient died on the first day post-procedure (1.8%) and all-cause 30 day mortality was 5.5% (3 of 55 patients). One patient had a significant post-procedural aortic regurgitation of > grade 2. Symptomatic improvement was evident in most patients, with reduction in functional capacity grade from 3.2 ± 0.6 at baseline to 1.4 ± 0.7. The most common post-procedural complication was complete heart block, which necessitated permanent pacemaker implantation in 37% of patients.

Conclusions: The Israeli first year experience of transcatheter aortic valve implantation using the CoreValve self-expandable system demonstrates an effective and safe procedure for the treatment of severe aortic stenosis in patients at high surgical risk.






[1] AVR = aortic valve replacement



[2] TAVI = transcatheter aortic valve implantation


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel