        The Sixth Vital Sign: End-Tidal Co2 in Pediatric Trauma Patients during Transport

         

        Amir Vardi, Inbal Levin, Gideon Paret, Zohar Barzilay

         

        Pediatric Transport Team of the Pediatric Critical Care Unit, Sheba Medical Center, Tel Hashomer; and Sackler School of Medicine, Tel Aviv University

         

        Transport of pediatric trauma victims, within as well as between medical centers, has become a frequent event and an integral activity of pediatric critical care units. Monitoring patients during transport is of utmost importance, as an unstable environment poses an increased threat to the patient's stability. The level of monitoring and care should approximate that of the critical care unit. Monitoring end-tidal CO2 (EtCO2) has become routine for many pediatric intensive care unit patients but technical problems have limited its use during transport.

        Our transport team uses a transportable EtCO2 monitor of the side-stream type (NPB 75), requiring very small samples; midstream sampling overcomes humidity interference. The monitor is small and lightweight, operates on a rechargeable battery and is especially designed for the demanding environment of transport.

        From October 1997 through January 1999, 187 pediatric patients, 62 of whom were trauma victims, were transported for a total of 45 hours, including 2 hours of in-flight transport. Age range was 3 months to 16 years. Of the 53 monitored for EtCO2, in 9 (17%) monitoring resulted in a significant, immediate change of treatment during transport.

        We find EtCO2 an important adjunct in monitoring pediatric trauma patients during transport. In addition to conventional monitoring of heart rate, blood pressure, respiratory rate, body temperature and blood oxygen saturation, we suggest EtCO2 as the sixth vital sign that should be monitored.

        מרץ 1998

        אנבל אהרון-מאור, יאיר לוי ויהודה שינפלד
        עמ'

        Fibrosarcoma after Silicone Breast Augmentation: Associated?

         

        Anabel Aharon-Maor, Yair Levy, Yehuda Schoenfeld

         

        Medical Dept. B, Chaim Sheba Medical Center and Sackler Faculty of Medicine, Tel Aviv University

         

        We describe a 42-year-old woman in whom bilateral fibrosarcoma of the breast was diagnosed 15 years after bilateral breast augmentation with silicone implants. 3 years prior to admission the implants were replaced and 2 years prior to admission mammography showed a nodule in the left breast which biopsy showed to be fibrosarcoma. The implants were removed from both breasts and she was given chemotherapy but later that year underwent bilateral mastectomy. Despite chemotherapy, as well as adjuvant radiotherapy, the disease progressed, with involvement of the lungs and the skin of the left hemithorax. She was admitted repeatedly for severe anemia caused by bleeding from the malignant skin lesions, and died less than 2 years after diagnosis of the disease.

        Not all reports in the literature find a significant connection between silicone implants and subsequent development of breast cancer, but there are reports that do connect them. Breast fibrosarcoma is not significantly more frequent after silicone augmentation, but still there is controversy as to whether there is a connection between silicone implants and breast malignancy. In the patient we present, the prolonged exposure to silicone may have been a predisposing factor for the development of bilateral fibrosarcoma, since other known risk factors for breast cancer were denied.