• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Mon, 25.11.24

Search results


September 2009
B. Belhassen, T. Ohayon-Tsioni, A. Glick and S. Viskin

Background: The predictive value of electrophysiologic studies depends on the aggressiveness of the programmed ventricular stimulation protocol.

Objectives: To assess if non-inducibility with an "aggressive" protocol of PVS[1] identifies post-infarction patients with low ejection fraction (EF[2] ≤ 30%) who may safely be treated without implantable cardioverter defibrillator.

Methods: We studied 154 patients during a 9 year period. Our aggressive PVS protocol included: a) stimulus current five times the diastolic threshold (≤ 3 mA) and b) repetition of double and triple extrastimulation at the shortest coupling intervals that capture the ventricle.

Results: Sustained ventricular tachyarrhythmias were induced in 116 patients (75.4%) and 112 (97%) of them received an ICD[3] (EPS[4]+/ICD+ group). Of the 38 non-inducible patients, 34 (89.5%) did not receive an ICD (EPS-/ICD- group). In comparison to the EPS+/ICD+ group, EPS-/ICD- group patients were older (69 ± 10 vs. 65 ± 10 years, P < 0.05), had a lower EF (23 ± 5% vs. 25 ± 5%,  P < 0.05) and a higher prevalence of left bundle branch block (45.5% vs. 20.2%, P < 0.005). Follow-up was longer for EPS+/ICD+ patients (40 ± 26 months) than for EPS-/ICD- patients (27 ± 22 months) (P = 0.011). Twelve EPS+/ICD+ patients (10.7%) and 5 EPS-/ICD- patients (14.7%) died during follow-up (P = 0.525). Kaplan-Meier survival curves did not show a significant difference between the two groups (P = 0.18).
Conclusions: The mortality rate in patients without inducible VTAs[5] using an aggressive PVS protocol and who did not undergo subsequent ICD implantation is not different from that of patients with inducible arrhythmias who received an ICD. Using this protocol, as many as one-fourth of primary prevention ICD implants could be spared without compromising patient prognosis







[1] PVS = programmed ventricular stimulation



[2] EF = ejection fraction



[3] ICD = implantable cardioverter defibrillator



[4] EPS electrophysiologic study



[5] VTA = ventricular tachyarrhythmias


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel