Eran Leshem MD, Michael Rahkovich MD, Anna Mazo MD, Mahmoud Suleiman MD, Miri Blich MD, Avishag Laish-Farkash MD, Yuval Konstantino MD, Rami Fogelman MD, Boris Strasberg MD, Michael Geist MD, Israel Chetboun MD, Moshe Swissa MD, Michael Ilan MD, Aharon Glick MD, Yoav Michowitz MD, Raphael Rosso MD, Michael Glikson MD and Bernard Belhassen MD

Background: Limited information exists about detailed clinical characteristics and management of the small subset of Brugada syndrome (BrS) patients who had an arrhythmic event (AE).

Objectives: To conduct the first nationwide survey focused on BrS patients with documented AE.

Methods: Israeli electrophysiology units participated if they had treated BrS patients who had cardiac arrest (CA) (lethal/aborted; group 1) or experienced appropriate therapy for tachyarrhythmias after prophylactic implantable cardioverter defibrillator (ICD) implantation (group 2).

Results: The cohort comprised 31 patients: 25 in group 1, 6 in group 2. Group 1: 96% male, mean CA age 38 years (range 13–84). Nine patients (36%) presented with arrhythmic storm and three had a lethal outcome; 17 (68%) had spontaneous type 1 Brugada electrocardiography (ECG). An electrophysiology study (EPS) was performed on 11 patients with inducible ventricular fibrillation (VF) in 10, which was prevented by quinidine in 9/10 patients. During follow-up (143 ± 119 months) eight patients experienced appropriate shocks, none while on quinidine. Group 2: all male, age 30–53 years; 4/6 patients had familial history of sudden death age < 50 years. Five patients had spontaneous type 1 Brugada ECG and four were asymptomatic at ICD implantation. EPS was performed in four patients with inducible VF in three. During long-term follow-up, five patients received ≥ 1 appropriate shocks, one had ATP for sustained VT (none taking quinidine). No AE recurred in patients subsequently treated with quinidine.

Conclusions: CA from BrS is apparently a rare occurrence on a national scale and no AE occurred in any patient treated with quinidine.

Roman Nevzorov MD, Avital Porter MD, Shanie Mostov DVM, Shirit Kazum MD, Alon Eisen MD, Gustavo Goldenberg MD, Zaza Iakobishvili MD, Jairo Kusniec MD, Gregory Golovchiner MD, Boris Strasberg MD and Moti Haim MD

Background: Gender-related differences (GRD) exist in the outcome of patients with cardiac resynchronization therapy (CRT).

Objectives: To assess GRD in patients who underwent CRT.

Methods: A retrospective cohort of 178 patients who were implanted with a CRT in a tertiary center 2005–2009 was analyzed. Primary outcome was 1 year mortality. Secondary endpoints were readmission and complication rates.

Results: No statistically significant difference was found in 1 year mortality rates (14.6% males vs. 11.8% females, P = 0.7) or in readmission rate (50.7% vs. 41.2%, P = 0.3). The complication rate was only numerically higher in women (14.7% vs. 5.6%, P = 0.09). Men more often had CRT-defibrillator (CRT-D) implants (63.2% vs. 35.3%, P = 0.003) and had a higher rate of ischemic cardiomyopathy (79.2% vs. 38.2%, P < 0.001). There was a trend to higher incidence of ventricular fibrillation/ventricular tachycardia in men before CRT implantation (29.9% vs. 14.7%, P = 0.07%). A higher proportion of men upgraded from implantable cardioverter defibrillator (ICD) to CRT-D, 20.8% vs. 8.8%, P = 0.047. On multivariate model, chronic renal failure was an independent predictor of 1 year mortality (hazard ratio [HR] 3.6; 95% confidence interval [95%CI] 1.4–9.5), CRT-D had a protective effect compared to CRT-pacemaker (HR 0.3, 95%CI 0.12–0.81).

Conclusions: No GRD was found in 1 year mortality or readmission rates in patients treated with CRT. There was a trend toward a higher complication rate in females. Men were implanted more often with CRT-D and more frequently underwent upgrading of ICD to CRT-D.

 

February 2018
January 2017
Gustavo Goldenberg MD, Tamir Bental MD, Udi Kadmon MD, Ronit Zabarsky MD, Jairo Kusnick MD, Alon Barsheshet MD, Gregory Golovchiner MD and Boris Strasberg MD

Background: Syncope prognosis varies widely: 1 year mortality may range from 0% in the case of vasovagal events up to 30% in the presence of heart disease. 

Objectives: To assess the outcomes and prognosis of patients with implantable cardiac defibrillator (ICD) and indication of primary prevention and compare patients presenting with or without prior syncope.

Methods: We reviewed the charts of 75 patients who underwent ICD implantation with the indication of primary prevention and history of syncope and compared them to a control group of 80 patients without prior syncope. We assessed the number of ventricular tachycardia (VT), ventricular fibrillation (VF), shock, anti-tachycardia pacing (ATP), and death in each group during the follow-up.

Results: Mean follow-up was 893 days (810–976, 95% confidence interval) (no difference between groups). Patients with prior syncope had a higher ejection fraction (EF) (35.5 ± 12.6 vs. 31.4 ± 8.76, P = 0.02), more episodes of VT (21.3% vs. 3.8%, P = 0.001) and VF (8% vs. 0%, P = 0.01) and also received more electric shocks (18.7% vs. 3.8%, P = 0.004) and ATP (17.3% vs. 6.2%, P = 0.031). There were no differences in inappropriate shocks (6.7% vs. 5%, P = 0.74), in cardiovascular mortality (cumulative 5 year estimate 29.9% vs. 32.2% P = 0.97) and any death (cumulative 5 year estimate 38.1% vs. 48.9% P = 0.18) during the follow-up.

Conclusions: Syncopal patients before ICD implantation seem to have more episodes of VT/VF and shock or ATP. No mortality differences were observed

 

June 2016
Gustavo Goldenberg MD, Tamir Bental MD, Udi Kadmon MD, Ronit Zabarsky MD, Jairo Kusnick MD, Alon Barsheshet MD, Gregory Golovchiner MD and Boris Strasberg MD

Background: Syncope is a common clinical condition spanning from benign to life-threatening diseases. There is sparse information on the outcomes of syncopal patients who received an implantable cardiac defibrillator (ICD) for primary prevention of sudden cardiac death (SCD). 

Objectives: To assess the outcomes and prognosis of patients who underwent implantable cardiac defibrillator (ICD) implantation for primary prevention of SCD and compare them to patients who presented with or without prior syncope.

Methods: We compared the medical records of 75 patients who underwent ICD implantation for primary prevention of SCD and history of syncope to those of a similar group of 80 patients without prior syncope. We assessed the episodes of ventricular tachycardia (VT), ventricular fibrillation (VF), shock, anti-tachycardia pacing (ATP) and mortality in each group during follow-up.

Results: Mean follow-up was 893 days (810–976, 95%CI) (no difference between groups). There was no significant difference in gender or age. Patients with prior syncope had a higher ejection fraction rate (35.5 ± 12.6 vs. 31.4 ± 8.76, P = 0.02), experienced more episodes of VT (21.3% vs. 3.8%, P = 0.001) and VF (8% vs. 0%, P = 0.01), and received more electric shocks (18.7% vs. 3.8%, P = 0.004) and ATP (17.3% vs. 6.2%, P = 0.031). There were no differences in inappropriate shocks (6.7% vs. 5%, P = 0.74), cardiovascular mortality (cumulative 5 year estimate 29.9% vs. 32.2%, P = 0.97) and any death (cumulative 5 year estimate 38.1% vs. 48.9%, P = 0.18).

Conclusions: Patients presenting with syncope before ICD implantation seemed to have more episodes of VT/VF and shock or ATP. No differences in mortality were observed

 

August 2015
Guy Topaz MD, Moti Haim MD, Jairo Kusniec MD, Shirit Kazum MD, Gustavo Goldenberg MD, Gregory Golovchiner MD, Ran Kornowski MD, Boris Strasberg MD and Alon Eisen MD

Background: Cardiac resynchronization therapy (CRT) is a non-pharmacological option for patients with heart failure and interventricular dyssynchrony. Elevated red cell distribution width (RDW) reflects higher size and heterogeneity of erythrocytes and is associated with poor outcome in patients with chronic heart failure. 

Objectives: To examine the association between RDW levels and outcomes after CRT implantation.

Methods: We conducted a cohort analysis of 156 patients (126 men, median age 69.0 years) who underwent CRT implantation in our institution during 2004–2008. RDW was measured at three time points before and after implantation. Primary outcome was defined as all-cause mortality, and secondary outcome as hospital re-admissions. We investigated the association between RDW levels and primary outcome during a median follow-up of 61 months.

Results: Ninety-five patients (60.9%) died during follow-up. Higher baseline RDW levels were associated with all-cause mortality (unadjusted HR 1.35, 95%CI 1.20–1.52, P < 0.001). On multivariate analysis adjusted for clinical, electrocardiographic and laboratory variables, baseline RDW levels were associated with mortality (HR 1.33, 95%CI 1.16–1.53). RDW levels 6 months and 12 months post-implantation were also associated with mortality (HR 1.22, 95%CI 1.08–1.38, P = 0.001; and HR 1.15, 95%CI 1.01–1.32, P = 0.02, respectively). Patients who were re-admitted to hospital during follow-up (n=78) had higher baseline RDW levels as compared to those who were not (14.9%, IQR 14.0, 16.0% vs. 14.3%, IQR 13.7, 15.0%, respectively, P = 0.03). 

Conclusion: An elevated RDW level before and after CRT implantation is independently associated with all-cause mortality. 

 

August 2012
E. Kadmon, D. Menachemi, J. Kusniec, M. Haim, M. Geist and B. Strasberg

Background: The implantable loop recorder (ILR) is an important tool for the evaluation of unexplained syncope, particularly in cases of rarely occurring arrhythmia.

Objectives: To review the clinical experience of two Israeli medical centers with the ILR. Methods: We reviewed the medical records of patients with unexplained syncope evaluated with the ILR at Rabin Medical Center (2006–2010) and Wolfson Medical Center (2000–2009).

Results: The study group included 75 patients (44 males) followed for 11.9 ± 9.5 months after ILR implantation. Patients’ mean age was 64 ± 20 years. The ILR identified an arrhythmic mechanism of syncope in 20 patients (17 bradyarrhythmias, 3 tachyarrhythmias) and excluded arrhythmias in 12, for a diagnostic yield of 42.7%. It was not diagnostic in 17 patients (22.7%) at the time of explant 26 patients (34.7%) were still in follow-up. In two patients ILR results that were initially negative were reversed by later ILR tracings. The patients with bradyarrhythmias included 9 of 16 (56.3%) with surface electrocardiogram conduction disturbances and 2 of 12 (16.7%) with negative findings on carotid sinus massage. All bradyarrhythmic patients received pacemakers the seven patients for whom post-intervention data were available had no or mild symptoms.

Conclusions: The ILR has a high diagnostic yield. Pre-ILR findings correlating with the ILR results are conduction disturbances (positive predictor of arrhythmia) and negative carotid sinus massage results (negative predictor of arrhythmia). Proper patient instruction is necessary to obtain accurate results. Caution is advised when excluding an arrhythmia on the basis of ILR tracings, and long-term follow-up is warranted.

July 2012
R. Nevzorov, T. Ben-Gal, B. Strasberg and M. Haim
June 2012
P. Codner, R. Nevzorov, J. Kusniec, M. Haim, R. Zabarski and B. Strasberg

Background: Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. Recently this practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test.

Objectives: To compare the outcome of ICD recipients who underwent DFT testing and those in whom no testing was performed.

Methods: A total of 213 eligible patients were implanted with an ICD between 2004 and 2009. DFT testing was performed in 80. We compared total mortality, appropriate and inappropriate ICD shocks, and anti-tachycardia pacing (ATP) events between DFT and non-DFT patients during a follow-up of 2 years.

Results: On comparing the DFT and non-DFT groups, we found a 2 year mortality rate of 7.5% versus 8.3%, respectively (P = 0.8). Furthermore, 20.7% of patients in the DFT group and 12.4% in the non-DFT group had at least one episode of ICD shock (P = 0.15). With regard to ICD treatment (ICD shocks or ATP events), 57.7% in the DFT group and 64.2% in the non-DFT group received appropriate treatments (P = 0.78).

Conclusions: No significant differences in the incidence of 2 year mortality or percentage of ICD treatment emerged between the DFT and non-DFT groups.
 

June 2008
R. Rosso, A. Click, M. Glikson, M. Swissa, S. Rosenhek, I. Shetboun, V. Khalamizer, M. Boulos, M. Geist, B. Strasberg, M. Ilan and B. Belhassen

background: many electrophysiologists recommend implantable cardioverter defibrillators for patients with Brugada syndrome who are cardiac arrest survivors or presumed at high risk of sudden death (patients with syncope or a familial history of sudden death or those with inducible ventricular fibrillation at electrophysiologic study).

objectives: To assess the efficacy and complications of ICD therapy in patients with Brugada syndrome.

Methods: The indications, efficacy and complications of ICD therapy in all patient with Brugada syndrome who underwent ICD implantation in 12 Israeli centers between 1994 and 2007 were analyzed.

Results: there were 59 patients (53 males, 89.8%) with a mean age of 44.1 years. At diagnosis 42 patients (71.2%) were symptomatic while 17 (28.8%) were asymptomatic. The indications for ICD implantation were: a history of cardiac arrest (n=11, 18.6%), syncope (n=31, 52.5%), inducible VF in symptomatic patients (n=14, 23.7%), and a family history of sudden death (n=3, 0.5%). The overall inducibility rates of VF were 89.2% and 93.3% among the symptomatic and a symptomatic patients, respectively (P=NS). During a follow-up of 4-160 (45+-35) months, all patients (except one who died from cancer) are alive. Five patients (8.4%), all with a history of cardiac arrest, had appropriate ICD discharge. Conversely, none of the patients without prior cardiac arrest had appropriate device therapy during 39+-30 month follow-up. Complications were encountered in 19 patients (32%). Inappropriate shocks occurred in 16 (27.1%) due to lead failure/dislodgment (n=5), T wave oversensing (n=2), device failure (n=1), sinus tachycardia (n=4), and supraventricular tachycardia (n=4). One patient suffered a pneumothorax and another a brachial plexus injury during the implant procedure. One patient suffered a late (2 months) perforation of the right ventricle by the implanted lead. Eleven patients (18.6%) required a reintervention either for infection (n=1) or lead problems (n=10). Eight patients (13.5%) required psychiatric assistance due to complications related to the ICD (mostly inappropriate shocks in 7 patients).

Conclusions: In this Israeli population with Brugada syndrome treated with ICD, appropriate device therapy was limited to cardiac arrest survivors while none of the other patients including those with syncope and/or inducible VF suffered an arrhythmic event. The overall complication rate was high.
 

December 2004
Z. Iakobishvili, J. Kusniec, A. Mazur, A. Battler and B. Strasberg

Background: Device replacement or revision may constitute 25% of pacemaker procedures. In patients needing pacemaker system replacement the usual approach is from the ipsilateral side of the previous system. In cases where the contralateral side is used the previous pulse generator is removed.

Objective: To test the feasibility of implanting a new system in the contralateral side without the removal of the old system.

Methods: We present 10 patients, age range 30–88 (median 73), with clinical indication of pacemaker replacement where the contralateral side was used. In eight patients the replacement was lead-related, and in the remaining two was due to other clinical indications. In all cases the ipsilateral approach was felt to be contraindicated because of local vein and/or pocket complications. Following the new pacemaker implantation the old system was reprogrammed at the lowest rate, lowest output and highest sensitivity.

Results: All patients underwent uneventful implantation. Post-surgery monitoring and Holter recordings failed to show any interference of the old system.

Conclusions: In clinically indicated cases it is feasible to implant a new device in the contralateral side without removing the old pulse generator, thereby avoiding an additional surgical procedure and reducing periprocedural complications.