November 2020
Hezzy Shmueli MD, Arie Steinvil MD, Galit Aviram MD, Sileman Moaad MD, Adam Sharon MD, Achiude Bendet MD, Simon Biner MD, Yacov Shacham MD, Jack Sherez MD, Ricki Megidish MD, Yifat Hasin MD, Ester Elazar MD, Sevan Letourneau-Shesaf MD, Gad Keren MD ,Shlomo Berliner MD, and Yan Topilsky MD

Background: Acute pulmonary embolism (PE) is considered to be one of the most common cardiovascular diseases with considerable mortality. Conflicting data imply possible role for echocardiography in assessing this disease.

Objectives: To determine which of the echo parameters best predicts short-term and long-term mortality in patients with PE.

Methods: We prospectively enrolled 235 patients who underwent computed tomography of pulmonary arteries (CTPA) and transthoracic Echocardiography (TTE) within < 24 hours. TTE included a prospectively designed detailed evaluation of the right heart including right ventricular (RV) myocardial performance index (RIMP), RV end diastolic and end systolic area, RV fractional area change, acceleration time (AT) of pulmonary flow and visual estimation. Interpretation and performance of TTE were blinded to the CTPA results.

Results: Although multiple TTE parameters were associated with PE, all had low discriminative capacity (AUC < 0.7). Parameters associated with 30-day mortality in univariate analysis were acceleration time (AT) < 81 msec (P = 0.04), stroke volume < 44 cc (P = 0.005), and RIMP > 0.42 (P = 0.05). The only RV independent echo parameter associated with poor long-term prognosis (adjusted for significant clinical, and routine echo associates of mortality) was RIMP (hazard ratio 3.0, P = 0.04). The only independent RV echo parameters associated with mortality in PE patients were RIMP (P = 0.05) and AT (P = 0.05). Addition of RIMP to nested models eliminated the significance of all other parameters assessing RV function.

Conclusions: Doppler-based parameters like pulmonary flow AT, RIMP, and stroke volume, have additive value in addition to visual RV estimation to assess prognosis in patients with PE.

December 2019
Oholi Tovia-Brodie MD, Sevan Letourneau-Shesaf MD, Aviram Hochstadt MD, Arie Steinvil MD, Raphael Rosso MD, Ariel Finkelstein MD and Yoav Michowitz MD

Background: Patients with right bundle branch block (RBBB) prior to transcatheter aortic valve implantation (TAVI) are at high risk for immediate post-procedural heart block and long-term mortality when discharged without a pacemaker.

Objectives: To test whether prophylactic permanent pacemaker implantation (PPI) is beneficial.

Methods: Of 795 consecutive patients who underwent TAVI, 90 patients had baseline RBBB. We compared characteristics and outcomes of the prophylactic PPI with post-TAVI PPI. Need for pacing was defined as  greater than 1% ventricular pacing.

Results: Forty patients with RBBB received a prophylactic PPI (group 1), and in 50 the decision was based on standard post-procedural indications (group 2). There were no significant differences in clinical baseline characteristics. One patient developed a tamponade after a PPI post-TAVI. A trend toward shorter hospitalization duration in group 1 patients was observed (P = 0.06). On long-term follow-up of 848 ± 56 days, no differences were found in overall survival (P = 0.77), the composite event-free survival of both mortality and hospitalizations (P = 0.66), or mortality and syncope (P = 0.65). On multivariate analysis, independent predictors of the need for pacing included baseline PR interval increase of 10ms (odds ratio [OR] 1.21 per 10 ms increment 95% confidence interval [95%CI] 1.02–1.44, P = 0.028), and the use of new generation valves (OR 3.92, 95%CI 1.23–12.46, P = 0.023).

Conclusions: In patients with baseline pre-TAVI RBBB, no outcome differences were found with prophylactic PPI. On multivariate analysis, predictors of the need for pacing included baseline long PR interval, and the use of newer generation valves.