• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


June 2012
T. Fuchs, M. Leitman, I. Zysman, T. Amini and A. Torjman

Background: Microvolt T-wave alternans (MTWA) measures subtle beat-to-beat fluctuations in the T-wave amplitude. It was found to be associated with cardiac electrical instability in patients with ischemic and dilated cardiomyopathy.

Objectives: To investigate the reproducibility of the MTWA test results in patients with ischemic heart disease.

Methods: The study group comprised patients with ischemic heart disease who participated in a rehabilitation program at the Assaf Harofeh Medical Center. MTWA was measured during a bicycle exercise test at the first encounter and repeated after one week.

Results: Of the 40 study patients with coronary artery disease, 4 had an indeterminate result and were excluded from the data analysis; 5 had a positive MTWA in the first and second study (14%), 27 had a negative MTWA in the first and second study (75%), and 4 had a negative MTWA in the first study and a positive MTWA in the second study (11%). Overall, there was a correlation between the results of the first and the second study in 89% of the patients (kappa = 0.652, P = 0.0001).

Conclusions: MTWA measurements are reproducible in the short term in patients with coronary artery disease.

November 2002
Jorge Rouvier, MD, Claudio Gonzalez, MD, Alejandra Scazziota, PhD and Raul Altman, MD

Background: Elevated fibrinogen, considered an independent risk factor for coronary disease, stratifies an individual as high risk for coronary disease. A risk marker requires little intra-individual variability during a long period.

Objectives: To establish intra-individual variability of fibrinogen levels in patients with coronary disease.

Methods: We investigated fibrinogen levels prospectively in four blood samples drawn from 267 patients with a history of arterial disease (arterial group) and from 264 patients with cardiac valve replacements (valvular group). The samples were taken during the course of 78.7 and 78.8 days from the arterial and valvular groups respectively.

Results: Marked intra-individual dispersion with a reliability coefficient of 0.541 was found in the arterial group and 0.547 in the valvular group. The Bland-Altman test showed low probability to obtain similar results in different samples from the same individual. These results show large intra-individual variability, with similarities in the arterial as well as in the valvular group.

Conclusions: It is not possible to stratify a patient by a specific fibrinogen dosage.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel