• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


March 2022
Israel Mazin MD, Ori Vaturi MD, Rafael Kuperstein MD, Roy Beigel MD, Micha Feinberg MD, and Sagit Ben Zekry MD

Background: Estimated frequency of aortic stenosis (AS) in those over 75 years of age is 3.4%. Symptomatic patients with severe AS have increased morbidity and mortality and aortic valve replacement should be offered to improve life expectancy and quality of life.

Objectives: To identify whether systolic time intervals can identify severe AS.

Methods: The study comprised 200 patients (mean age 79 years, 55% men). Patients were equally divided into normal, mild, moderate, or severe AS. All patients had normal ejection fraction. Acceleration time (AT) was defined as the time from the beginning of systolic flow to maximal velocity; ejection time (ET) was the time from onset to end of systolic flow. The relation of AT/ET was calculated. Death or aortic valve intervention were documented.

AT increased linearly with the severity of AS, similar to ET and AT/ET ratio (P for trend < 0.05 for all). Receiver-operator characteristic curve analysis demonstrated that AT can identify severe AS with a cutoff ≥ 108 msec with 100% sensitivity and 98% specificity, while a cutoff of 0.34 when using AT/ET ratio can identify severe AS with 96% sensitivity and 94% specificity. Multivariate analysis adjusting to sex, stroke volume index, heart rate, and body mass index showed similar results. Kaplan-Meier curve for AT ≥ 108 and AT/ET ≥ 0.34 predicted death or aortic valve intervention in a 3-year follow-up.

Conclusions: Acceleration time and AT/ET ratio are reliable measurements for identifying patients with severe AS. Furthermore, AT and AT/ET were able to predict aortic valve replacement or death

April 2018
Anne Graham Cummiskey MBBS, Amit Segev MD, Michael Segel MD, Jonathan Buber MD, Victor Guetta MD, Israel M. Barbash MD, Dan Elian MD, Elad Asher MD, Ori Vaturi MD and Paul Fefer MD

Background: Previous studies have demonstrated the utility of exercise hemodynamics during right heart catheterization (RHC) in the diagnosis of diastolic dysfunction (DD). Little data exists regarding exercise hemodynamics during RHC in symptomatic systemic sclerosis (SSc) patients. 

Objectives: To assess the added diagnostic value of using exercise hemodynamics during RHC in assessment of patients with symptomatic SSc.

Methods: We performed 22 RHCs in 17 SSc patients with dyspnea and/or pulmonary arterial hypertension (PAH). Exercise was performed in 15 RHCs using isotonic arm exercises while holding a 1 kg weight in each hand. Measurements of pulmonary arterial pressure (PAP), pulmonary arterial wedge pressure (PAWP), and cardiac output (CO) were taken at rest and during peak exercise. 

Results: Normal resting RHC (PAP 22 ± 3 mmHg, PAWP 11 ± 3 mmHg) was found in seven cases. Of these, exercise induced elevation in PAP was found in three (38 ± 7 mmHg), and exercise induced elevation in PAWP was found in four (24 ± 6 mmHg). Elevated resting PAP was found in 15 (41 ± 11 mmHg) with minor changes in exercise. Of the 22 RHCs, elevation of the PAWP was found in 11 (50%), half of which were in response to exercise. 

Conclusions: In symptomatic SSc patients, exercise hemodynamics provides important information on diastolic dysfunction that is not available with non-invasive testing. Findings on exercise RHC can explain patient symptoms in up to 50% of cases. Earlier and more accurate diagnosis of patient symptoms can aid in tailoring the correct therapy for each.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel