• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


July 2020
Ilan Merdler MD MHA, Aviram Hochstadt, Amichai Sheffy MD, Sharon Ohayon MD MHA, Itamar Loewenstein MD and Daniel Trotzky MD

Background: Emergency department (ED) overcrowding is associated with worse patient outcomes.

Objectives: To determine whether physician assistants (PAs), fairly recently integrated into the Israeli healthcare system, improve patient outcomes and ED timings.

Methods: We compared patients seen by physicians with patients seen by PAs and then by physicians between January and December 2018 using propensity matching. Patients were matched for age, gender, triage level, and decision to hospitalize. Primary endpoints included patient mortality, re-admittance. and leaving on own accord rates. Secondary endpoints were ED timing landmarks.

Results: Patients first seen by PAs were less likely to leave on their own accord (MD1 1.5%, PA 1.0%, P = 0.015), had lower rates of readmission within 48 hours (MD1 2.1%, PA 1.5%, P= 0.028), and were quicker to be seen, to have medications prescribed, and to undergo imaging without differences in timings until decisions were made or total length of stay. Patients seen by a physician with the assistance of a PA were attended to quicker (MD2 47.79 minutes, range 27.70–78.82 vs. MD + PA 30.59 minutes, range 15.77–54.85; P < 0.001) without statistically significant differences in primary outcomes. Mortality rates were similar for all comparisons.

Conclusions: Patients first seen by PAs had lower rates of re-admittance or leaving on their own accord and enjoyed shorter waiting times. Pending proper integration into healthcare teams, PAs can further improve outcomes in EDs and patient satisfaction.

February 2020
Avi Ohayon MD, Saleh Esa MD and Alexander Rubowitz MD

Background: There are several ways to remove silicone oil (SO) from the vitreous cavity.

Objective: To describe a simple, safe and inexpensive method of 2-port SO removal.

Method: Medical charts of 33 patients who underwent SO removal combined with cataract extraction were retrospectively reviewed, from a cohort of 119 patients who had silicone oil removal. The primary outcome was the rate of re-detachment, secondary outcomes included visual acuity (VA) and intraoperative and postoperative complications.

Results: Mean follow-up time was 27.6 months (0.25–147 ± 33.1), and mean tamponade duration prior to SO removal was 16.77 months (4–51.5 ± 14.6). The re-detachment rate was 3% (one patient). Postoperatively, seven patients (20%) had epiretinal membrane (ERM), eight patients had posterior capsule opacification (24%), and proliferative vitreoretinopathy (PVR) was diagnosed in two patients (6%). Compared to the mean VA (logarithm of the minimum angle of resolution [LogMAR]) at the preoperative examination, the mean VA (LogMAR) improved significantly at the last visit when including all ranges of VA (n=32, LogMAR 1.52 vs. 1.05 P = 0.0002 [Student's t-test] and P = 0.001 [Wilcoxon test]).

Conclusions: The technique described is fast and simple, keeping the posterior capsule intact in pseudophakic patients, which is advantageous in the event of future re-detachment necessitating SO reinjection. Rates of re-detachment and postoperative ERM and PVR were low. Furthermore, our method does not require the use of a surgical microscope with posterior segment viewing systems, or opening a full disposable vitrectomy set, thus drastically reducing the procedure's cost.

September 2009
B. Belhassen, T. Ohayon-Tsioni, A. Glick and S. Viskin

Background: The predictive value of electrophysiologic studies depends on the aggressiveness of the programmed ventricular stimulation protocol.

Objectives: To assess if non-inducibility with an "aggressive" protocol of PVS[1] identifies post-infarction patients with low ejection fraction (EF[2] ≤ 30%) who may safely be treated without implantable cardioverter defibrillator.

Methods: We studied 154 patients during a 9 year period. Our aggressive PVS protocol included: a) stimulus current five times the diastolic threshold (≤ 3 mA) and b) repetition of double and triple extrastimulation at the shortest coupling intervals that capture the ventricle.

Results: Sustained ventricular tachyarrhythmias were induced in 116 patients (75.4%) and 112 (97%) of them received an ICD[3] (EPS[4]+/ICD+ group). Of the 38 non-inducible patients, 34 (89.5%) did not receive an ICD (EPS-/ICD- group). In comparison to the EPS+/ICD+ group, EPS-/ICD- group patients were older (69 ± 10 vs. 65 ± 10 years, P < 0.05), had a lower EF (23 ± 5% vs. 25 ± 5%,  P < 0.05) and a higher prevalence of left bundle branch block (45.5% vs. 20.2%, P < 0.005). Follow-up was longer for EPS+/ICD+ patients (40 ± 26 months) than for EPS-/ICD- patients (27 ± 22 months) (P = 0.011). Twelve EPS+/ICD+ patients (10.7%) and 5 EPS-/ICD- patients (14.7%) died during follow-up (P = 0.525). Kaplan-Meier survival curves did not show a significant difference between the two groups (P = 0.18).
Conclusions: The mortality rate in patients without inducible VTAs[5] using an aggressive PVS protocol and who did not undergo subsequent ICD implantation is not different from that of patients with inducible arrhythmias who received an ICD. Using this protocol, as many as one-fourth of primary prevention ICD implants could be spared without compromising patient prognosis







[1] PVS = programmed ventricular stimulation



[2] EF = ejection fraction



[3] ICD = implantable cardioverter defibrillator



[4] EPS electrophysiologic study



[5] VTA = ventricular tachyarrhythmias


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel