Tamar Slobodov MD, Gergana Marincheva MD, Michael Rahkovich MD, Andrei Valdman MD, Yonatan Kogan MD, Avishag Laish-Farkash MD PhD

Background: Cardiac implantable electronic devices (CIEDs) with endocardial leads crossing the tricuspid valve can lead to or worsen tricuspid regurgitation (TR), causing substantial morbidity and mortality. Despite a recent randomized controlled study revealing a low short-term incidence of device-related TR (DRT) post-CIED implantation, uncertainties persist regarding the efficacy of intra-procedural 2-dimensional transthoracic echocardiography (2DTTE) in preventing long-term TR.

Objectives: To conduct a long-term follow-up study on patients with CIED implants based on a previous study conducted at our hospital.

Methods: In a retrospective study at Assuta Ashdod Medical Center (2018–2019), patients undergoing de-novo CIED implantation with (n=39, group 1) or without (n=51, group 2) intra-procedural 2DTTE were analyzed. Clinical, demographic, and long-term (> 1 year) echocardiographic data were collected and compared.

Results: The study included 90 patients (mean age 72.3 ± 11.0 years, 63% male, 23% ICD, 50% active leads, follow-up 32.8 ± 11 months). TR aggravation was found in 25% of patients (13 in group 1, 10 in group 2), with no statistical difference between groups. Multivariate analysis identified a history of atrial fibrillation (AF) as the sole significant factor in long-term TR deterioration (OR=3.44, 95%CI 1.13–10.43, P = 0.029). Other clinical, demographic, echocardiographic, and device-related factors did not significantly contribute to long-term DRT.

Conclusions: After one-year post-CIED implantation, the incidence of DRT significantly increases. Intra-procedural 2DTTE does not effectively reduce long-term DRT, suggesting that implantation-related mechanisms are less likely the primary cause. AF likely plays a major role in the pathogenesis of long-term TR in this subset post-CIED implantation.

Yana Kakzanov MD, Yamama Alsana, Tal Brosh-Nissimov MD, Emanuel Harari MD, Michael Rahkovich MD, Yonatan Kogan MD, Emma Shvets RN MA, Gergana Marincheva MD, Lubov Vasilenko MD, Avishag Laish-Farkash MD PhD

Background: Cardiac implantable electronic devices (CIEDs) are associated with risks of device-related infections (DRI) impacting major adverse outcomes. Staphylococcus aureus (SA) is a leading cause of early pocket infection and bacteremia. While studies in other surgical contexts have suggested that nasal mupirocin treatment and chlorhexidine skin washing may reduce colonization and infection risk, limited data exist for CIED interventions.

Objectives: To assess the impact of SA decolonization on DRI rates.

Methods: We conducted a retrospective, single-center observational study on consecutive patients undergoing CIED interventions (March 2020–March 2022). All patients received pre-procedure antibiotics and chlorhexidine skin washing. Starting in March 2021, additional pre-treatment with mupirocin for SA decolonization was administered. DRI rates within 6 months post-implantation were compared between patients treated according to guidelines (Group 1) and those receiving mupirocin in addition to the recommended guidelines (Group 2).

Results: The study comprised 276 patients (age 77 ± 10 years; 60% male). DRI occurred in five patients (1.8%);80% underwent cardiac resynchronization therapy procedures. In Group 1 (n=177), four patients (2.2%) experienced DRI 11–48 days post-procedure; three with pocket infection (two with negative cultures and one with local Pseudomonas) and one with methicillin-sensitive SA endocarditis necessitating device extraction. In Group 2 (n=99), only one patient (1%) had DRI (Strep. dysgalactiae endocarditis) 135 days post-procedure (P = NS).

Conclusions: The routine decolonization of SA with mupirocin, in addition to guideline-directed protocols, did not significantly affect DRI rates. Larger prospective studies are needed to evaluate the preventive role of routine SA decolonization in CIED procedures.

January 2022
Gergana Marincheva MD, Tal Levi MD, Olga Perelshtein Brezinov MD, Andrei Valdman MD, Michael Rahkovich MD, Yonatan Kogan MD, and Avishag Laish-Farkash MD PhD

Background: Endocardial leads of permanent pacemakers (PPM) and implantable defibrillators (ICD) across the tricuspid valve (TV) can lead to tricuspid regurgitation (TR) or can worsen existing TR with subsequent severe morbidity and mortality.

Objectives: To evaluate prospectively the efficacy of intraprocedural 2-dimentional-transthoracic echocardiography (2DTTE) in reducing/preventing lead-associated TR.

Methods: We conducted a prospective randomized controlled study comparing echocardiographic results in patients undergoing de-novo PPM/ICD implantation with intraprocedural echo-guided right ventricular (RV) lead placement (Group 1, n=56) versus non-echo guided implantation (Group 2, n=55). Lead position was changed if TR grade was more than baseline in Group 1. Cohort patients underwent 2DTTE at baseline and 3 and/or 6 months after implantation. Excluded were patients with baseline TR > moderate or baseline ≥ moderate RV dysfunction.

Results: The study comprised 111 patients (74.14 ± 11 years of age, 58.6% male, 19% ICD, 42% active leads). In 98 patients there was at least one follow-up echo. Two patients from Group 1 (3.6%) needed intraprocedural RV electrode repositioning. Four patients (3.5%, 2 from each group, all dual chamber PPM, 3 atrial fibrillation, 2 RV pacing > 40%, none with intraprocedural reposition) had TR deterioration during 6 months follow-up. One patient from Group 2 with baseline mild-moderate aortic regurgitation (AR) had worsening TR and AR within 3 months and underwent aortic valve replacement and TV repair.

Conclusions: The rate of mechanically induced lead-associated TR is low; thus, a routine intraprocedural 2DTTE does not have a significant role in reducing/preventing it

September 2009
H.D. Danenberg, G. Marincheva, B. Varshitzki, H. Nassar, C. Lotan

Background: Stent thrombosis is a rare but devastating complication of coronary stent implantation. The incidence and potential predictors were assessed in a "real world” single center.

 Objectives: To examine whether socioeconomic status indeed affects the occurrence of stent thrombosis.

Methods: We searched our database for cases of "definite" stent thrombosis (according to the ARC Dublin definitions). Each case was matched by procedure date, age and gender; three cases of stenting did not result in stent thrombosis. Demographic and clinical parameters were compared and socioeconomic status was determined according to a standardized polling and market survey database.

Results: A total of 3401 patients underwent stent implantation in our hospital during the period 2004–2006. Their mean age was 63 ± 11 years, and 80% were males. Twenty-nine cases (0.85%) of “definite” sub-acute/late stent thrombosis were recorded. Mortality at 30 days was recorded in 1 patient (3.5%). Thrombosis occurred 2 days to 3 years after stent implantation. All patients presented with acute myocardial infarction. Premature clopidogrel discontinuation was reported in 60%. Patients with stent thrombosis had significantly higher rates of AMI[1] at the time of the initial procedure (76 vs. 32%, P < 0.001) and were cigarette smokers (60 vs. 28%, P < 0.001). Drug-eluting stents were used less in the stent thrombosis group. There was no difference in stent diameter or length between the two groups. Socioeconomic status was significantly lower at the stent thrombosis group, 3.4 ± 2.4 vs. 5.4 ± 2.6 (mean ± SD, scale 1–10, P < 0.01).

Conclusions: The incidence rate of stent thrombosis is at least 0.85% in our population. It appears in patients with significantly lower socioeconomic status and with certain clinical predictors. These results warrant stricter follow-up and support the policy of healthcare providers regarding patients at risk for stent thrombosis.






[1] AMI = acute myocardial infarction


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel