August 2023
Maya Shina MD, Fabio Kusniec MD, Guy Rozen MD MHA, Shemy Carasso MD FESC FASE, David Planer MD, Ronny Alcalai MD, Liza Grosman-Rimon PhD, Gabby Elbaz-Greener MD MHA DRCPSC, Offer Amir MD FACC

Background: Among the most frequent complications following transcatheter aortic valve replacement (TAVR) is hemostasis imbalance that presents either as thromboembolic or bleeding. Deviations in platelet count (PC) and mean platelet volume (MPV) are markers of hemostasis imbalance.

Objectives: To determine the predictive value of pre- and post-procedural PC and MPV fL 1-year all-cause mortality in patients who underwent TAVR.

Methods: In this population-based study, we included 236 TAVR patients treated at the Tzafon Medical Center between 1 June 2015 and 31 August 2018. Routine blood samples for serum PC levels and MPV fL were taken just before the TAVR and 24-hour post-TAVR. We used backward regression models to evaluate the predictive value of PC and MPV in all-cause mortality in TAVR patients.

Results: In this study cohort, MPV levels 24-hour post-TAVR that were greater than the cohort median of 9 fL (interquartile range 8.5–9.8) were the strongest predictor of 1-year mortality (hazard ratio 1.343, 95% confidence interval 1.059–1.703, P-value 0.015). A statistically significant relationship was seen in the unadjusted regression model as well as after the adjustment for clinical variables.

Conclusions: Serum MPV levels fL 24-hour post-procedure were found to be meaningful markers in predicting 1-year all-cause mortality in patients after TAVR.

March 2023
Alla Lubovich MD, Mariana Issawy MD, Liza Grosman-Rimon PhD, Fabio Kusniec MD, Ibrahim Marai MD, Doron Sudarsky MD, Edo Y. Birati MD, Offer Amir MD FACC, Shemy Carasso MD FESC FASE, Gabby Elbaz-Greener MD MHA DRCPSC

Background: Acute coronary syndrome (ACS) represents a spectrum of ischemic myocardial disease including unstable angina (UA), non-ST-segment elevation myocardial infarction (NSTEMI), and ST-elevation myocardial infarction (STEMI). Various prognostic scores were developed for patients presenting with NSTEMI-ACS. Among these scores, the GRACE risk score offers the best discriminative performance for prediction of in-hospital and 6-month mortality. However, the GRACE score is limited and cannot be used in several ethnic populations. Moreover, it is not predictive of clinical outcomes other than mortality.

Objective: To assess the prognostic value of traditional cardiovascular risk factors and laboratory biomarkers in predicting 6-month major adverse cardiac and cerebrovascular events (MACCE), including hospitalization, recurrent percutaneous coronary intervention (PCI), stroke, and cardiovascular mortality in patients with NSTEMI treated with PCI.

Methods: This retrospective study included consecutive patients admitted with an initial diagnosis of NSTEMI to the cardiac intensive care unit (CICU) at the Tzafon Medical Center, Israel, between April 2015 and August 2018 and treated by PCI within 48 hours of admission.

Results: A total of 223 consecutive patients with NSTEMI treated by PCI were included in the study. Logarithmebrain natriuretic peptide (LogₑBNP), prior MI, and Hb levels were found to be significant predictors of any first MACCE. Only logₑBNP was found to be an independent predictor of a first MACCE event by multivariate logistic regression analysis.

Conclusions: LogₑBNP is an independent predictor of worse prognosis in patients with NSTEMI. Routine evaluation of BNP levels should be considered in patients admitted with NSTEMI.

May 2018
Roman Nevzorov MD, Avital Porter MD, Shanie Mostov DVM, Shirit Kazum MD, Alon Eisen MD, Gustavo Goldenberg MD, Zaza Iakobishvili MD, Jairo Kusniec MD, Gregory Golovchiner MD, Boris Strasberg MD and Moti Haim MD

Background: Gender-related differences (GRD) exist in the outcome of patients with cardiac resynchronization therapy (CRT).

Objectives: To assess GRD in patients who underwent CRT.

Methods: A retrospective cohort of 178 patients who were implanted with a CRT in a tertiary center 2005–2009 was analyzed. Primary outcome was 1 year mortality. Secondary endpoints were readmission and complication rates.

Results: No statistically significant difference was found in 1 year mortality rates (14.6% males vs. 11.8% females, P = 0.7) or in readmission rate (50.7% vs. 41.2%, P = 0.3). The complication rate was only numerically higher in women (14.7% vs. 5.6%, P = 0.09). Men more often had CRT-defibrillator (CRT-D) implants (63.2% vs. 35.3%, P = 0.003) and had a higher rate of ischemic cardiomyopathy (79.2% vs. 38.2%, P < 0.001). There was a trend to higher incidence of ventricular fibrillation/ventricular tachycardia in men before CRT implantation (29.9% vs. 14.7%, P = 0.07%). A higher proportion of men upgraded from implantable cardioverter defibrillator (ICD) to CRT-D, 20.8% vs. 8.8%, P = 0.047. On multivariate model, chronic renal failure was an independent predictor of 1 year mortality (hazard ratio [HR] 3.6; 95% confidence interval [95%CI] 1.4–9.5), CRT-D had a protective effect compared to CRT-pacemaker (HR 0.3, 95%CI 0.12–0.81).

Conclusions: No GRD was found in 1 year mortality or readmission rates in patients treated with CRT. There was a trend toward a higher complication rate in females. Men were implanted more often with CRT-D and more frequently underwent upgrading of ICD to CRT-D.

 

March 2018
Nizar Andria MD, Ali Nassar MD, Fabio Kusniec MD, Diab Ghanim MD, Dahud Qarawani MD, Erez Kachel MD, Khaled Taha MD, Offer Amir MD FACC and Shemy Carasso MD FESC

Background: Coronary artery disease (CAD) has known risk factors. Individual risks related to specific ethnicities are complex and depend on genetic predisposition and lifestyle.

Objectives: To compare the nature and prevalence of risk factors in Arab and non-Arab ethnic patients with symptomatic obstructive CAD referred for coronary angiography.

Methods: CAD, defined as coronary angiography with a ≥ 50% narrowing in ≥ 1 vessel, was diagnosed in 1029 patients admitted to a medical center between April 2014 and October 2015. Patients were divided into two groups according to ethnic origin: Arab vs. non-Arab. Demographics, clinical presentation, and coronary risk profiles were compared.

Results: The diagnosis of CAD was made during ST-elevation myocardial infarction (STEMI) in 198 patients (19%) who arrived at the clinic, 620 (60%) with unstable angina/non-STEMI, and 211 (21%) with stable angina. Patients with symptomatic CAD and Arab ethnicity were 47% more prevalent than non-Arab patients presenting with CAD. The Arab patients were appoximately 5 years younger, 50% more likely to be active smokers, 25% more likely to be obese, and more likely to have a family history of CAD. Other coronary risk factors were similar between the two groups.

Conclusions: Smoking and obesity, which are potentially modifiable CAD risk factors, stood out as major risk factors, in addition to genetic disposition, among Arab and non-Arab patients with symptomatic CAD. Screening and educational interventions for smoking cessation, obesity control, and compliance to treatment of co-morbidities should be attempted in order to decrease CAD in the Arab population.

August 2015
Guy Topaz MD, Moti Haim MD, Jairo Kusniec MD, Shirit Kazum MD, Gustavo Goldenberg MD, Gregory Golovchiner MD, Ran Kornowski MD, Boris Strasberg MD and Alon Eisen MD

Background: Cardiac resynchronization therapy (CRT) is a non-pharmacological option for patients with heart failure and interventricular dyssynchrony. Elevated red cell distribution width (RDW) reflects higher size and heterogeneity of erythrocytes and is associated with poor outcome in patients with chronic heart failure. 

Objectives: To examine the association between RDW levels and outcomes after CRT implantation.

Methods: We conducted a cohort analysis of 156 patients (126 men, median age 69.0 years) who underwent CRT implantation in our institution during 2004–2008. RDW was measured at three time points before and after implantation. Primary outcome was defined as all-cause mortality, and secondary outcome as hospital re-admissions. We investigated the association between RDW levels and primary outcome during a median follow-up of 61 months.

Results: Ninety-five patients (60.9%) died during follow-up. Higher baseline RDW levels were associated with all-cause mortality (unadjusted HR 1.35, 95%CI 1.20–1.52, P < 0.001). On multivariate analysis adjusted for clinical, electrocardiographic and laboratory variables, baseline RDW levels were associated with mortality (HR 1.33, 95%CI 1.16–1.53). RDW levels 6 months and 12 months post-implantation were also associated with mortality (HR 1.22, 95%CI 1.08–1.38, P = 0.001; and HR 1.15, 95%CI 1.01–1.32, P = 0.02, respectively). Patients who were re-admitted to hospital during follow-up (n=78) had higher baseline RDW levels as compared to those who were not (14.9%, IQR 14.0, 16.0% vs. 14.3%, IQR 13.7, 15.0%, respectively, P = 0.03). 

Conclusion: An elevated RDW level before and after CRT implantation is independently associated with all-cause mortality. 

 

August 2012
E. Kadmon, D. Menachemi, J. Kusniec, M. Haim, M. Geist and B. Strasberg

Background: The implantable loop recorder (ILR) is an important tool for the evaluation of unexplained syncope, particularly in cases of rarely occurring arrhythmia.

Objectives: To review the clinical experience of two Israeli medical centers with the ILR. Methods: We reviewed the medical records of patients with unexplained syncope evaluated with the ILR at Rabin Medical Center (2006–2010) and Wolfson Medical Center (2000–2009).

Results: The study group included 75 patients (44 males) followed for 11.9 ± 9.5 months after ILR implantation. Patients’ mean age was 64 ± 20 years. The ILR identified an arrhythmic mechanism of syncope in 20 patients (17 bradyarrhythmias, 3 tachyarrhythmias) and excluded arrhythmias in 12, for a diagnostic yield of 42.7%. It was not diagnostic in 17 patients (22.7%) at the time of explant 26 patients (34.7%) were still in follow-up. In two patients ILR results that were initially negative were reversed by later ILR tracings. The patients with bradyarrhythmias included 9 of 16 (56.3%) with surface electrocardiogram conduction disturbances and 2 of 12 (16.7%) with negative findings on carotid sinus massage. All bradyarrhythmic patients received pacemakers the seven patients for whom post-intervention data were available had no or mild symptoms.

Conclusions: The ILR has a high diagnostic yield. Pre-ILR findings correlating with the ILR results are conduction disturbances (positive predictor of arrhythmia) and negative carotid sinus massage results (negative predictor of arrhythmia). Proper patient instruction is necessary to obtain accurate results. Caution is advised when excluding an arrhythmia on the basis of ILR tracings, and long-term follow-up is warranted.

June 2012
P. Codner, R. Nevzorov, J. Kusniec, M. Haim, R. Zabarski and B. Strasberg

Background: Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. Recently this practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test.

Objectives: To compare the outcome of ICD recipients who underwent DFT testing and those in whom no testing was performed.

Methods: A total of 213 eligible patients were implanted with an ICD between 2004 and 2009. DFT testing was performed in 80. We compared total mortality, appropriate and inappropriate ICD shocks, and anti-tachycardia pacing (ATP) events between DFT and non-DFT patients during a follow-up of 2 years.

Results: On comparing the DFT and non-DFT groups, we found a 2 year mortality rate of 7.5% versus 8.3%, respectively (P = 0.8). Furthermore, 20.7% of patients in the DFT group and 12.4% in the non-DFT group had at least one episode of ICD shock (P = 0.15). With regard to ICD treatment (ICD shocks or ATP events), 57.7% in the DFT group and 64.2% in the non-DFT group received appropriate treatments (P = 0.78).

Conclusions: No significant differences in the incidence of 2 year mortality or percentage of ICD treatment emerged between the DFT and non-DFT groups.
 

December 2004
Z. Iakobishvili, J. Kusniec, A. Mazur, A. Battler and B. Strasberg

Background: Device replacement or revision may constitute 25% of pacemaker procedures. In patients needing pacemaker system replacement the usual approach is from the ipsilateral side of the previous system. In cases where the contralateral side is used the previous pulse generator is removed.

Objective: To test the feasibility of implanting a new system in the contralateral side without the removal of the old system.

Methods: We present 10 patients, age range 30–88 (median 73), with clinical indication of pacemaker replacement where the contralateral side was used. In eight patients the replacement was lead-related, and in the remaining two was due to other clinical indications. In all cases the ipsilateral approach was felt to be contraindicated because of local vein and/or pocket complications. Following the new pacemaker implantation the old system was reprogrammed at the lowest rate, lowest output and highest sensitivity.

Results: All patients underwent uneventful implantation. Post-surgery monitoring and Holter recordings failed to show any interference of the old system.

Conclusions: In clinically indicated cases it is feasible to implant a new device in the contralateral side without removing the old pulse generator, thereby avoiding an additional surgical procedure and reducing periprocedural complications.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel