• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


May 2018
Roman Nevzorov MD, Avital Porter MD, Shanie Mostov DVM, Shirit Kazum MD, Alon Eisen MD, Gustavo Goldenberg MD, Zaza Iakobishvili MD, Jairo Kusniec MD, Gregory Golovchiner MD, Boris Strasberg MD and Moti Haim MD

Background: Gender-related differences (GRD) exist in the outcome of patients with cardiac resynchronization therapy (CRT).

Objectives: To assess GRD in patients who underwent CRT.

Methods: A retrospective cohort of 178 patients who were implanted with a CRT in a tertiary center 2005–2009 was analyzed. Primary outcome was 1 year mortality. Secondary endpoints were readmission and complication rates.

Results: No statistically significant difference was found in 1 year mortality rates (14.6% males vs. 11.8% females, P = 0.7) or in readmission rate (50.7% vs. 41.2%, P = 0.3). The complication rate was only numerically higher in women (14.7% vs. 5.6%, P = 0.09). Men more often had CRT-defibrillator (CRT-D) implants (63.2% vs. 35.3%, P = 0.003) and had a higher rate of ischemic cardiomyopathy (79.2% vs. 38.2%, P < 0.001). There was a trend to higher incidence of ventricular fibrillation/ventricular tachycardia in men before CRT implantation (29.9% vs. 14.7%, P = 0.07%). A higher proportion of men upgraded from implantable cardioverter defibrillator (ICD) to CRT-D, 20.8% vs. 8.8%, P = 0.047. On multivariate model, chronic renal failure was an independent predictor of 1 year mortality (hazard ratio [HR] 3.6; 95% confidence interval [95%CI] 1.4–9.5), CRT-D had a protective effect compared to CRT-pacemaker (HR 0.3, 95%CI 0.12–0.81).

Conclusions: No GRD was found in 1 year mortality or readmission rates in patients treated with CRT. There was a trend toward a higher complication rate in females. Men were implanted more often with CRT-D and more frequently underwent upgrading of ICD to CRT-D.

 

January 2017
Gustavo Goldenberg MD, Tamir Bental MD, Udi Kadmon MD, Ronit Zabarsky MD, Jairo Kusnick MD, Alon Barsheshet MD, Gregory Golovchiner MD and Boris Strasberg MD

Background: Syncope prognosis varies widely: 1 year mortality may range from 0% in the case of vasovagal events up to 30% in the presence of heart disease. 

Objectives: To assess the outcomes and prognosis of patients with implantable cardiac defibrillator (ICD) and indication of primary prevention and compare patients presenting with or without prior syncope.

Methods: We reviewed the charts of 75 patients who underwent ICD implantation with the indication of primary prevention and history of syncope and compared them to a control group of 80 patients without prior syncope. We assessed the number of ventricular tachycardia (VT), ventricular fibrillation (VF), shock, anti-tachycardia pacing (ATP), and death in each group during the follow-up.

Results: Mean follow-up was 893 days (810–976, 95% confidence interval) (no difference between groups). Patients with prior syncope had a higher ejection fraction (EF) (35.5 ± 12.6 vs. 31.4 ± 8.76, P = 0.02), more episodes of VT (21.3% vs. 3.8%, P = 0.001) and VF (8% vs. 0%, P = 0.01) and also received more electric shocks (18.7% vs. 3.8%, P = 0.004) and ATP (17.3% vs. 6.2%, P = 0.031). There were no differences in inappropriate shocks (6.7% vs. 5%, P = 0.74), in cardiovascular mortality (cumulative 5 year estimate 29.9% vs. 32.2% P = 0.97) and any death (cumulative 5 year estimate 38.1% vs. 48.9% P = 0.18) during the follow-up.

Conclusions: Syncopal patients before ICD implantation seem to have more episodes of VT/VF and shock or ATP. No mortality differences were observed

 

June 2016
Gustavo Goldenberg MD, Tamir Bental MD, Udi Kadmon MD, Ronit Zabarsky MD, Jairo Kusnick MD, Alon Barsheshet MD, Gregory Golovchiner MD and Boris Strasberg MD

Background: Syncope is a common clinical condition spanning from benign to life-threatening diseases. There is sparse information on the outcomes of syncopal patients who received an implantable cardiac defibrillator (ICD) for primary prevention of sudden cardiac death (SCD). 

Objectives: To assess the outcomes and prognosis of patients who underwent implantable cardiac defibrillator (ICD) implantation for primary prevention of SCD and compare them to patients who presented with or without prior syncope.

Methods: We compared the medical records of 75 patients who underwent ICD implantation for primary prevention of SCD and history of syncope to those of a similar group of 80 patients without prior syncope. We assessed the episodes of ventricular tachycardia (VT), ventricular fibrillation (VF), shock, anti-tachycardia pacing (ATP) and mortality in each group during follow-up.

Results: Mean follow-up was 893 days (810–976, 95%CI) (no difference between groups). There was no significant difference in gender or age. Patients with prior syncope had a higher ejection fraction rate (35.5 ± 12.6 vs. 31.4 ± 8.76, P = 0.02), experienced more episodes of VT (21.3% vs. 3.8%, P = 0.001) and VF (8% vs. 0%, P = 0.01), and received more electric shocks (18.7% vs. 3.8%, P = 0.004) and ATP (17.3% vs. 6.2%, P = 0.031). There were no differences in inappropriate shocks (6.7% vs. 5%, P = 0.74), cardiovascular mortality (cumulative 5 year estimate 29.9% vs. 32.2%, P = 0.97) and any death (cumulative 5 year estimate 38.1% vs. 48.9%, P = 0.18).

Conclusions: Patients presenting with syncope before ICD implantation seemed to have more episodes of VT/VF and shock or ATP. No differences in mortality were observed

 

October 2015
Zaza Iakobishvili MD PhD, Adaya Weissler MD, Kiril Buturlin MD, Gustavo Goldenberg MD, Boris Strassberg MD, Ruth Tur MD and David Hasdai MD FESC

Background: The kinetics of high sensitivity cardiac troponin T (hs-cTnT) levels after elective, biphasic, direct-current cardioversion for persistent atrial fibrillation/flutter remains unknown.

Methods: We examined hs-cTnT kinetics in 24 patients at baseline and at 2, 6 and 24 hours post-cardioversion, and again at 7 and 30 days. We also examined levels of creatine kinase, aspartate aminotransferase, lactate dehydrogenase, brain natriuretic peptide (BNP), and high sensitivity C-reactive protein (hs-CRP).

Results: Median (25th, 75th interquartiles) baseline hs-cTnT concentration was 19.8 (10.4, 35.2) ng/L with 14 patients presenting with levels above the 99th percentile (13 ng/L). Hs-cTnT levels did not change significantly over time although they tended to decrease by 30 days, 18.8 ng/L (12.5, 23.3). There was no significant rise in other markers of myocardial injury. Similarly, BNP and hs-CRP levels were elevated at baseline and tended to decrease over time.

Conclusions: Patients with persistent atrial fibrillation/flutter have elevated hs-cTnT levels, as part of a general rise in biomarkers such as BNP and hs-CRP, without a further rise after cardioversion. After cardioversion, there is a gradual non-significant decrease in biomarker levels over time, and thus a rise in hs-cTnT levels should not be attributed to cardioversion. 

 

August 2015
Guy Topaz MD, Moti Haim MD, Jairo Kusniec MD, Shirit Kazum MD, Gustavo Goldenberg MD, Gregory Golovchiner MD, Ran Kornowski MD, Boris Strasberg MD and Alon Eisen MD

Background: Cardiac resynchronization therapy (CRT) is a non-pharmacological option for patients with heart failure and interventricular dyssynchrony. Elevated red cell distribution width (RDW) reflects higher size and heterogeneity of erythrocytes and is associated with poor outcome in patients with chronic heart failure. 

Objectives: To examine the association between RDW levels and outcomes after CRT implantation.

Methods: We conducted a cohort analysis of 156 patients (126 men, median age 69.0 years) who underwent CRT implantation in our institution during 2004–2008. RDW was measured at three time points before and after implantation. Primary outcome was defined as all-cause mortality, and secondary outcome as hospital re-admissions. We investigated the association between RDW levels and primary outcome during a median follow-up of 61 months.

Results: Ninety-five patients (60.9%) died during follow-up. Higher baseline RDW levels were associated with all-cause mortality (unadjusted HR 1.35, 95%CI 1.20–1.52, P < 0.001). On multivariate analysis adjusted for clinical, electrocardiographic and laboratory variables, baseline RDW levels were associated with mortality (HR 1.33, 95%CI 1.16–1.53). RDW levels 6 months and 12 months post-implantation were also associated with mortality (HR 1.22, 95%CI 1.08–1.38, P = 0.001; and HR 1.15, 95%CI 1.01–1.32, P = 0.02, respectively). Patients who were re-admitted to hospital during follow-up (n=78) had higher baseline RDW levels as compared to those who were not (14.9%, IQR 14.0, 16.0% vs. 14.3%, IQR 13.7, 15.0%, respectively, P = 0.03). 

Conclusion: An elevated RDW level before and after CRT implantation is independently associated with all-cause mortality. 

 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel