E. Bar-Yishay, A. Avital, C. Springer and I. Amirav

Background: In infants, small volume nebulizers with a face mask are commonly used to facilitate aerosol therapy. However, infants may be disturbed by mask application, causing poor mask-to-face seal and thus reducing the dose delivered.

Objectives: To compare lung function response to bronchodilator nebulization via two delivery devices: hood versus mask.

Methods: We studied 26 recurrently wheezy infants aged 45.8 weeks (95% confidence interval 39.6–52.0). Inhalations of 0.30 mg/kg salbutamol were administered in two alliqots 30 minutes apart using mask and hood in alternating order (M+H or H+M). Response to inhalations was measured by maximal expiratory flows at functional residual capacity at 5 minute intervals after each dose, and area under the VmaxFRC[1] curve was documented.

Results: A small but significant response to salbutamol was observed following the second inhalation with VmaxFRC, improving by 31.7% (7.2–56.2, P < 0.02) and AUC[2] by 425 %min (-154, 1004; P < 0.02). The improvement following salbutamol was similar by both delivery modalities but with a small but significantly better response when H was used after M (P < 0.01).

Conclusions: Nebulized salbutamol induced a variable but positive response in wheezy infants. Salbutamol via hood was as effective as conventional face mask delivery. Since it is simple and patient-friendly, it could replace the face mask method particularly with uncooperative infants.






[1] Vmax FRC = maximal expiratory flow at functional residual capacity



[2] AUC = area under the VmaxFRC curve


August 2009
S. Godfrey, C. Springer and E. Bar-Yishay
April 2009
E. Bar-Yishay, E. Matyashchuk, H. Mussaffi, M. Mei-Zahav, D. Prais, S. Hananya, G. Steuer and H. Blau

Background: The forced oscillation technique is a non-invasive and effort-independent technique and is well suited for lung function measurement in young children. FOT[1] employs small-amplitude pressure oscillations superimposed on normal breathing. Therefore, it has the advantage over conventional lung function techniques in that it does not require patient cooperation for conducting respiratory maneuvers.

Objectives: To test the feasibility of the FOT test in preschool children and to compare the results to the commonly used spirometry before and after the administration of bronchodilator therapy.

Methods: Forty-six children (median age 4.9 years, range 1.8–18.3) attending the Pulmonary Clinic at Schneider Children's Medical Center tried to perform FOT and routine spirometry. Results were retrospectively analyzed. 

Results: Of the 46 children 40 succeeded in performing FOT and only 29 succeeded in performing simple spirometry. All but one of the 32 children aged 4 years and above (97%) could perform both tests. Nine of 14 children (64%) aged 4 and less could perform the FOT but only 3 (21%) could perform spirometry. Baseline values of respiratory resistance measured at 6 Hz (R6) negatively correlated with body length (r2 = 0.68, P < 0.005). Twenty-four children performed both tests before and after bronchodilator therapy. A significant concordance was found between the measured responses to bronchodilators by FOT and spirometry (P < 0.01). Only one child had a negative response by FOT but a positive response by spirometry.

Conclusions: The FOT is a simple, non-invasive technique that does not require subject cooperation and thus can be utilized for measuring lung function in children as young as 2 years of age. Furthermore, the FOT was shown to reliably measure response to bronchodilator therapy.






[1] FOT = forced oscillation technique



 
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel