January 2019
Avi Sabbag MD, Yasmin Farhadian MD, Arwa Younis MD, David Luria MD, Osnat Gurevitz MD, Eyal Nof MD, Michael Glikson MD and Roy Beinart MD

Background: Catheter ablation (CA) is a well-established therapeutic option for patients with recurrent symptomatic atrial fibrillation (AF). Data on gender-related differences are limited with regard to baseline characteristics and long-term success rates of catheter ablation for AF.

Methods: We analyzed a cohort of 251 consecutive patients who underwent a first catheter ablation for AF in our institute during the period 2008 through 2015. All patients were followed by regular annual clinic visits, electrocardiograms, periodic 24–48 hour Holter monitoring, and loop recorders. The primary endpoint was first recurrence of AF during 1 year of follow-up.

Results: The cohort comprised 26% women (n=65), who were older (62.1 ± 9.6 vs. 54.4 ± 11.3 years, P < 0.01) and had a higher proportion of diabetes mellitus (23.1 vs. 5.4%, P < 0.001) than male patients. No other significant differences were evident. At 1 year follow-up, the cumulative survival free of AF was significantly higher in women compared with men (83% vs. 66%, respectively, log rank P value = 0.021). Subgroup analysis showed an interaction between female and small indexed left atrial diameter (LADi < 23 mm/m2).

Conclusions: Our findings suggest that women experience a significantly lower rate of AF recurrence post-CA compared with men. This gender-related advantage appears to be restricted to women without significant left atrial enlargement. It further implies that left atrial enlargement has a stronger negative impact on post-CA AF recurrence in females than in males. Due to the relatively small sample number of females further research is warranted to validate our conclusions.

August 2018
Yoav Michowitz MD, Jeremy Ben-Shoshan MD, Oholi Tovia-Brodie MD, Aharon Glick MD and Bernard Belhassen MD

Background: The incidence, characteristics, and clinical significance of catheter-induced mechanical suppression (trauma) of ventricular arrhythmias originating in the outflow tract (OT) area have not been thoroughly evaluated.

Objectives: To determine these variables among our patient cohort.

Methods: All consecutive patients with right ventricular OT (RVOT) and left ventricular OT (LVOT) arrhythmias ablated at two medical centers from 1998 to 2014 were included. Patients were observed for catheter-induced trauma during ablation procedures. Procedural characteristics, as well as response to catheter-induced trauma and long term follow-up, were recorded.

Results: During 288 ablations of OT arrhythmias in 273 patients (RVOT n=238, LVOT n=50), we identified 8 RVOT cases (3.3%) and 1 LVOT (2%) case with catheter-induced trauma. Four cases of trauma were managed by immediate radiofrequency ablation (RFA), three were ablated after arrhythmia recurrence within a few minutes, and two were ablated after > 30 minutes without arrhythmia recurrence. Patients with catheter-induced trauma had higher rates of repeat ablations compared to patients without: 3/9 (33%) vs. 12/264 (0.45%), P = 0.009. The three patients with arrhythmia recurrence were managed differently during the first ablation procedure (immediate RFA, RFA following early recurrence, and delayed RFA). During the repeat procedure of these three patients, no catheter trauma occurred in two, and in one no arrhythmia was observed.

Conclusions: Significant catheter-induced trauma occurred in 3.1% of OT arrhythmias ablations, both at the RVOT and LVOT. Arrhythmia suppression may last > 30 minutes and may interfere with procedural success. The optimal mode of management following trauma is undetermined.

April 2007
M. Suleiman, L. Gepstein, A. Roguin, R. Beyar and M. Boulos

Background: Catheter ablation is assuming a larger role in the management of patients with cardiac arrhythmias. Conventional fluoroscopic catheter mapping has limited spatial resolution and involves prolonged fluoroscopy. The non-fluoroscopic electroanatomic mapping technique (CARTO) has been developed to overcome these drawbacks.

Objectives: To report the early and late outcome in patients with different arrhythmias treated with radiofrequency ablation combined with the CARTO mapping and navigation system.

Methods: The study cohort comprised 125 consecutive patients with different cardiac arrhythmia referred to our center from January 1999 to July 2005 for mapping and/or ablation procedures using the CARTO system. Forty patients (32%) had previous failed conventional ablation or mapping procedures and were referred by other centers. The arrhythmia included atrial fibrillation (n=13), atrial flutter (n=38), atrial tachycardia (n=25), ventricular tachycardia (n=24), arrhythmogenic right ventricular dysplasia (n=9), and supraventricular tachycardia (n=16).

Results: During the study period, a total of 125 patients (mean age 49 ± 19 years, 59% males) underwent electrophysiological study and electroanatomic mapping of the heart chambers. Supraventricular arrhythmias were identified in 92 patients (73 %) and ventricular arrhythmias in 33 (27%). Acute and late success rates, defined as termination of the arrhythmia without anti-arrhythmic drugs, were 87% and 76% respectively. One patient (0.8%) developed a clinically significant complication.

Conclusions: The CARTO system advances our understanding of arrhythmias, and increases the safety, efficacy and efficiency of radiofrequency ablation.

 
 