Michal Laufer Perl MD, Ariel Finkelstein MD, Miri Revivo MHA, Shlomo Berliner MD, Itzhak Herz MD, Itay Rabinovich MD, Tomer Ziv-Baran PhD, Dalit Gotler, Gad Keren MD, Shmuel Bana MD and Yaron Arbel MD
Background: Atherosclerosis is a systemic disease. Nevertheless, the role of specific biomarkers as indicators for both coronary and carotid diseases is debatable.
Objectives: To evaluate the association of biomarkers with coronary and carotid disease.
Methods: We studied 522 consecutive patients with stable angina. All underwent coronary angiography and carotid duplex study on the same day. Patients with no apparent carotid plaques were evaluated for carotid intima-media thickness (CIMT) using an automated system that sampled over 100 samples in each carotid artery. Biochemical markers of cardiovascular disease risk were obtained at the time of coronary angiography, including serum lipid levels, hemoglobin A1C (HbA1c), white blood cell count, fibrinogen and high sensitivity C-reactive protein (hs-CRP).
Results: The mean age of the patients was 66 ± 11; 73% were males. Significant carotid stenosis was associated with higher hs-CRP (9.4 ± 17 vs. 6.3 ± 13 mg/L, P = 0.001), while high HbA1c (6.7 ± 1.6 vs. 5.8 ± 0.8%, P < 0.001) and low high density lipoprotein levels (40 ± 9 vs. 47 ± 14 mg/dl, P < 0.001) were linked with advanced coronary artery disease severity. In contrast, CIMT was not related to any of the biomarkers evaluated.
Conclusions: Although atherosclerosis is considered a systemic disease, different biomarkers are associated with coronary and carotid artery disease. Identifying the specific biomarkers for each disease is important for both prevention and for exposing the underlying pathophysiologic mechanism.
Yuval Nachalon MD, Ohad Hilly MD, Karl Segal MD, Eyal Raveh MD, Dania Hirsch MD, Eyal Robenshtok MD, Ilan Shimon MD, Jacob Shvero MD, Carlos Benbassat MD and Aron Popovtzer MD
Background: Radiation exposure is a well-known risk factor for well-differentiated thyroid cancer (WDTC). However, disease characteristics, optimal treatment, time from exposure to disease appearance, and the effect on outcome of age at initial exposure have yet to be determined.
Objectives: To identify the characteristics of radiation-induced thyroid carcinoma.
Methods: We retrieved the charts of all patients previously exposed to radiation who were diagnosed with WDTC between the years 1985 and 2013 in a tertiary referral center.
Results: Forty-four patients were reviewed. Median time from radiation exposure to diagnosis was 23 years. These patients had higher rates of aerodigestive symptoms and distant metastases on presentation than seen in non-radiated patients. Patients who were exposed to radiation before age 15 years tended to develop the disease at a younger age but had a longer latency period (34.7 ± 15.3 vs. 16.3 ± 10 years, P < 0.001) and none had significantly higher rates of vocal cord palsy, hoarseness on presentation, or aggressive variants on histology compared to patients exposed to radiation at an older age. Disease-specific survival (DSS) was the same for both groups and were similar to that seen in the general population (95% 20 year DSS).
Conclusions: Radiation-induced thyroid cancer has a more aggressive presentation and the age at exposure affects the presentation of disease. Nonetheless, appropriate treatment leads to a favorable prognosis.
Alisher Tashbayev MD, Alexander Belenky MD, Sergey Litvin MD, Michael Knizhnik MD, Gil N. Bachar MD and Eli Atar MD
Background: Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC).
Objectives: To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature.
Methods: During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complications rate were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature.
Results: Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18–99) and was noted to be significantly higher compared to similar studies (53–56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups.
Conclusions: In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.
Yigal Helviz MD, Ilia Dzigivker MD, David Raveh-Brawer MD, Moshe Hersch MD, Shoshana Zevin MD and Sharon Einav MD
Background: Enoxaparin is frequently used as prophylaxis for deep venous thrombosis in critically ill patients.
Objectives: To evaluate three enoxaparin prophylactic regimens in critical care patients with and without administration of a vasopressor.
Methods: Patients admitted to intensive care units (general and post-cardiothoracic surgery) without renal failure received, once daily, a subcutaneous fixed dose of 40 mg enoxaparin, a subcutaneous dose of 0.5 mg/kg enoxaparin, or an intravenous dose of 0.5 mg/kg enoxaparin. Over 5 days anti-activated factor X levels were collected before the daily administration and 4 hours after the injection.
Results: Overall, 16 patients received the subcutaneous fixed dose, 15 received the subcutaneous weight-based dosage, and 8 received the dose intravenously. Around two-fifths (38%) of the patients received vasopressors. There was no difference between anti-activated factor X levels regarding vasopressor administration. However, in all three groups the levels were outside the recommended range of 0.1 IU/ml and 0.3 IU/ml.
Conclusions: Although not influenced by vasopressor administration, the enoxaparin regimens resulted in blood activity levels outside the recommended range.
Oholi Tovia-Brodie MD, Yoav Michowitz MD, Aharon Glick MD, Raphael Rosso MD and Bernard Belhassen MD
Background: Left ventricular outflow tract (LVOT) arrhythmias are increasingly recognized. Data regarding the distribution of the sites of origin (SOO) of the arrhythmias are sparse.
Objectives: To describe the clinical characteristics of patients with LVOT arrhythmias and the distribution of their SOO.
Methods: All 42 consecutive patients with LVOT arrhythmias who underwent radiofrequency (RF) ablation during the period 2000–2014 were included. SOO identification was based on mapping activation, pace mapping and a 3D mapping system in eight patients.
Results: The study group comprised 28 males (66.7%) and 14 females, the mean age was 55 ±15.4 years. Most patients (76%) were symptomatic. All suffered from high grade ventricular arrhythmias. Left ventricular (LV) dysfunction (ejection fraction ≤ 50%) was observed in 15 patients (35.7%), of whom 14 (93.3%) were males. The left coronary cusp (LCC) was the most common arrhythmia SOO (64.3%). Other locations were the right coronary cusp (RCC), the junction of the RCC-LCC commissure, aortic-mitral continuity, endocardial-LVOT, and a coronary sinus branch. Acute successful ablation was achieved in 29 patients (69%) and transient arrhythmia abolition in 40 (95.2%). There was a trend for a higher success rate using cooled tip ablation catheters as compared to standard catheters. The ablation procedure significantly improved LV function in all patients with tachycardiomyopathy.
Conclusions: LVOT arrhythmias mostly originate from the LCC and are associated with LV dysfunction in 36% of patients. Knowledge regarding the prevalence of the anatomic origin of the LVOT arrhythmias may help achieve successful ablation. The use of cooled tip ablation catheters might have beneficial effects on the success rate of the procedure.
Amjad Shalabi MD, Ehud Raanani MD, Amihai Shinfeld MD, Rafael Kuperstein MD, Alexander Kogan MD, Alexander Lipey MD, Eyal Nachum MD and Dan Spiegelstein MD
Background: Prolonged life expectancy has increased the number of elderly high risk patients referred for surgical aortic valve replacement (AVR). These referred high risk patients may benefit from sutureless bioprosthesis procedures which reduce mortality and morbidity.
Objectives: To present our initial experience with sutureless aortic bioprotheses, including clinical and echocardiographic results, in elderly high risk patients referred for AVR.
Methods: Forty patients (15 males, mean age 78 ± 7 years) with symptomatic severe aortic stenosis underwent AVR with the 3F Enable™ or Perceval™ sutureless bioprosthesis during the period December 2012 to May 2014. Mean logistic EuroScore was 10 ± 3%. Echocardiography was performed preoperatively, intraoperatively, at discharge and at follow-up.
Results: There was no in-hospital mortality. Nine patients (22%) underwent minimally invasive AVR via a right anterior mini-thoracotomy and one patient via a J-incision. Four patients underwent concomitant coronary aortic bypass graft, two needed intraoperative repositioning of the valve, one underwent valve exchange due to inappropriate sizing, three (7.5%) had a perioperative stroke with complete resolution of neurologic symptoms, and one patient (2.5%) required permanent pacemaker implantation due to complete atrioventricular block. Mean preoperative and postoperative gradients were 44 ± 14 and 13 ± 5 mmHg, respectively. At follow-up, 82% of patients were in New York Heart Association functional class I and II.
Conclusions: Sutureless AVR can be used safely in elderly high risk patients with relatively low morbidity and mortality. The device can be safely implanted via a minimally invasive incision. Mid-term hemodynamic results are satisfactory, demonstrating significant clinical improvement.
Avi Moscovici MD, Michael Kogan MD, Iris Kliers MD, Olga Kukuy MD and Gad Segal MD