• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


August 2010
H. Danenberg, A. Finkelstein, R. Kornowski, A. Segev, D. Dvir, D. Gilon, G. Keren, A. Sagie, M. Feinberg, E. Schwammenthal, S. Banai, C. Lotan and V. Guetta

Background: The prevalence of aortic stenosis increases with advancing age. Once symptoms occur the prognosis in patients with severe aortic stenosis is poor. The current and recommended treatment of choice for these patients is surgical aortic valve replacement. However, many patients, mainly the very elderly and those with major comorbidities, are considered to be at high surgical risk and are therefore denied treatment. Recently, a transcatheter alternative to surgical AVR[1] has emerged.

Objectives: To describe the first year experience and 30 day outcome of transcatheter aortic self-expandable CoreValve implantation in Israel.

Methods: Transcatheter aortic valve implantation using the CoreValve system has been performed in Israel since September 2008. In the following year 55 patients underwent CoreValve TAVI[2] in four Israeli centers.

Results: Patients' mean age was 81.7 ± 7.1 years; there were 35 females and 20 males. The mean valve area by echocardiogram was 0.63 ± 0.16 cm2. The calculated mean logistic Euroscore was 19.3 ± 8%. Following TAVI, mean transvalvular gradient decreased from baseline levels of 51 ± 13 to 9 ± 3 mmHg. The rate of procedural success was 98%. One patient died on the first day post-procedure (1.8%) and all-cause 30 day mortality was 5.5% (3 of 55 patients). One patient had a significant post-procedural aortic regurgitation of > grade 2. Symptomatic improvement was evident in most patients, with reduction in functional capacity grade from 3.2 ± 0.6 at baseline to 1.4 ± 0.7. The most common post-procedural complication was complete heart block, which necessitated permanent pacemaker implantation in 37% of patients.

Conclusions: The Israeli first year experience of transcatheter aortic valve implantation using the CoreValve self-expandable system demonstrates an effective and safe procedure for the treatment of severe aortic stenosis in patients at high surgical risk.






[1] AVR = aortic valve replacement



[2] TAVI = transcatheter aortic valve implantation


October 2009
G. Goldenberg, A. Eisen, N. Weisenberg and H. Amital
April 2009
D. Dvir, A. Assali, H. Vaknin, A. Sagie, Y. Shjapira, A. Battler, E. Porat and R. Kornowski

The incidence of aortic valve stenosis is growing rapidly in the elderly. Nonetheless, many symptomatic patients are not referred for surgery usually because of high surgical risk. Unfortunately, percutaneous balloon valvuloplasty is unsatisfactory due to high recurrence rates. In 2002, Cribier and colleagues were the first to describe percutaneous aortic valve implantation, opening a new era of aortic stenosis management. In the present review we report a patient treated by this novel method, discuss and assess how it is implanated, report the findings of studies conducted to date, and suggest future directions for percutaneous treatment of aortic valve disease.
 

March 2008
I. Amirav and M.T. Newhouse

Background: Valved holding chambers with masks are commonly used to deliver inhaled medications to young children with asthma. Optimal mask properties such as their dead space volume have received little attention. The smaller the mask the more likely it is that a greater proportion of the dose in the VHC[1] will be inhaled with each breath, thus speeding VHC emptying and improving overall aerosol delivery efficiency and dose. Masks may have different DSV[2] and thus different performance.

Objectives: To compare both physical dead space and functional dead space of different face masks under various applied pressures.

Methods: The DSV of three commonly used face masks of VHCs was measured by water displacement both under various pressures (to simulate real-life application, dynamic DSV) and under no pressure (static DSV).

Results: There was a great variability of both static and dynamic dead space among various face mask for VHCs, which is probably related to their flexibility.

Conclusions: Different masks have different DSV characteristics. This variability should be taken into account when comparing the clinical efficacy of various VHCs. 

 






[1] VHC = valved holding chambers

[2] DSV = dead space volume


May 2007
I. Gotsman, A. Meirovitz, N. Meizlish, M. Gotsman, C. Lotan and D. Gilon

Background: Infective endocarditis is a common disease with significant morbidity and mortality.

Objectives: To define clinical and echocardiographic parameters predicting morbidity and in-hospital mortality in patients with infective endocarditis hospitalized in a tertiary hospital from 1991 to 2000.

Methods: All patients with definite IE diagnosed according to the Duke criteria were included. We examined relevant clinical features that might influence outcome.

Results: The study group comprised 100 consecutive patients, 77 with native valve and 23 with prosthetic valve endocarditis. The overall in-hospital mortality rate was 8%. There was a higher mortality in the PVE[1] group compared to the NVE[2] group (13% vs. 7%, P = 0.07). The mortality rate in each group, with or without surgery, was not significantly different. Clinical predictors of mortality were older age and hospital-acquired endocarditis. The presence of vegetations and their size were significant predictors of major embolic events and mortality. Staphylococcus aureus was a predictor of mortality (25% vs. 5%, P < 0.005) and abscess formation. Multivariate logistic analysis identified vegetation size and S. aureus as independent predictors of mortality.

Conclusions: Mortality is higher in older hospitalized patients. S. aureus is associated with a poor outcome. Vegetation size is an independent predictor of embolic events and of a higher mortality.







[1]PVE = prosthetic valve endocarditis

[2]NVE = native valve endocarditis


April 2007
Y. Shapira, D. E. Weisenberg, M. Vaturi, E. Sharoni, E. Raanani, G. Sahar, B. A. Vidne, A. Battler and A. Sagie

Backgound: The use of intraoperative transesophageal echocardiogram in patients with infective endocarditis is usually reserved for cases of inadequate preoperative testing or suspected extension to perivalvular tissue.

Objectives: To explore the impact of routine intraoperative TEE[1] in patients with infective endocarditis.

Methods: The impact of intraoperative TEE on the operative plan, anatomic-physiologic results, and hemodynamic assessment or de-airing was analyzed in 59 patients (38 males, 21 females, mean age 57.7 ± 16.8 years, range 20–82) operated for active infective endocarditis over 56 months.

Results: Immediate pre-pump echocardiography was available in 52 operations (86.7%), and changed the operative plan in 6 of them (11.5%). Immediate post-pump study was available in 59 patients (98.3%) and accounted for second pump-run in 6 (10.2%): perivalvular leak (3 cases), and immobilized leaflet, significant mitral regurgitation following vegetectomy, and failing right ventricle requiring addition of vein graft (1 case each). Prolonged de-airing was necessary in 6 patients (10.2%). In 5 patients (8.5%) the postoperative study aided in the evaluation and treatment of difficult weaning from the cardiopulmonary bypass pump. In 21 patients (35.6%) the application of intraoperative TEE affected at least one of the four pre-specified parameters.
Conclusions: Intraoperative TEE has an important role in surgery for infective endocarditis and should be routinely implemented







[1] TEE = transesophageal echocardiogram


D. Spiegelstein, P.l Ghosh, L. Sternik, S. Tager, A. Shinfeld and E. Raanani

Background: During the last decade new surgical techniques for mitral valve repair were developed. We have been using those techniques in order to widen the spectrum of patients eligible for MV[1] repair.

Objectives: To assess the operative and mid-term results a wide variety of surgical techniques.

Methods: From January 2004 through December 2006, 213 patients underwent MV repair in our institution. Valve pathology was degenerative in 123 patients (58%), ischemic in 37 (17%), showed annular dilatation in 25 (12%), endocarditis in 16 (8%), was rheumatic in 13 (6%), and due to other causes in 14 (7%). Preoperative New York Heart Association score was 2.35 ± 0.85 and ejection fraction 53 ± 12%. Isolated MV repair was performed in 90 patients (42%) and 158 concomitant procedures were done in 123 patients (58%). A wide variety of surgical techniques was used in order to increase the number of repairs compared to valve replacement.

Results: There were 7 in-hospital deaths (3.3%). NYHA[2] class improved from 2.19 ± 0.85 to 1.4 ± 0.6, and freedom from reoperation was 100%. Echocardiography follow-up of patients with degenerative MV revealed that 93% of the patients (115/123) were free of mitral regurgitation greater than 2+ grade. In patients operated by a minimal invasive approach there were no conversions to sternotomy, no late deaths, none required reoperation, and 96% were free of MR[3] greater than 2+ grade. The use of multiple surgical techniques enabled the repair of more than 80% of pure MR cases.

Conclusions: MV repair provides good perioperative and mid-term results, and supports the preference for MV repair over replacement, when feasible. Multiple valve repair techniques tailored to different pathologies increases the feasibility of mitral repair.







[1] MV = mitral valve

[2] NYHA = New York Heart Association

[3] MR = mitral regurgitation


December 2006
June 2006
K. Mahlab, M. Katz, S. Shimoni, M. Zborovsky and Z.M. Sthoeger
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel