Eyal R. Nachum MD, Ehud Raanani MD, Amit Segev MD, Victor Guetta MD, Ilan Hai MD, Amihai Shinfeld MD, Paul Fefer MD, Hamdan Ashraf MD, Israel Barabash MD, Amjad Shalabi MD and Dan Spiegelstein MD
Background: The rate of mitral bioprosthesis implantation in clinical practice is increasing. Transcatheter valve-in-valve implantation has been described for high risk patients requiring redo valve surgery.
Objectives: To report our experience with transapical valve-in-valve implantation for failed mitral bioprosthesis.
Methods: Since 2010, 10 patients have undergone transapical valve-in-valve implantation for failed bioprosthesis in our center. Aortic valve-in-valve implantation was performed in one of them and mitral valve-in-valve implantation in nine. Mean age was 82 ± 4 years and 6 were female (67%). Mean time from original mitral valve (MV) replacement to valve-in-valve procedure was 10.5 ± 3.7 years. Follow-up was completed by all patients with a mean duration of 13 ± 12 months.
Results: Preoperatively, all patients presented with significant mitral regurgitation; two with mitral stenosis due to structural valve failure. All nine patients underwent successful transapical valve-in-valve implantation with an Edwards Sapien™ balloon expandable valve. There was no in-hospital mortality. Mean and median hospital duration was 15 ± 18 and 7 days respectively. Valve implantation was successful in all patients and there were no major complications, except for major femoral access bleeding in one patient. At last follow-up, all patients were alive and in NYHA functional class I or II. Echocardiography follow-up demonstrated that mitral regurgitation was absent or trivial in seven patients and mild in two. At follow-up, peak and mean gradients changed from 26 ± 4 and 8 ± 2 at baseline to 16.7 ± 3 and 7.3 ± 1.5, respectively.
Conclusions: Transcatheter transapical mitral valve-in-valve implantation for failed bioprosthesis is feasible in selected high risk patients. Our early experience with this strategy is encouraging. Larger randomized trials with long-term clinical and echocardiographic follow-up are recommended.
Arie Y. Nemet MD, Leena Asalee MD, Yaron Lang MD, Daniel Briscoe MD and Ehud I. Assia MD
Background: One of the most alarming ocular injury trends in recent years has been the proliferation of paintball guns and the proportional increase in the number of ocular eye injuries caused by paintballs.
Objectives: To describe five cases of paintball eye injuries that resulted in loss of functional vision in four of them.
Methods: We conducted a retrospective interventional case series of the clinical course of five patients with paintball eye injuries treated in the ophthalmology departments of two medical centers.
Results: Five young males were evaluated for paintball injuries caused by blunt trauma. There was one case of full-thickness laceration (globe rupture). Four patients required one to five surgical interventions: three of these involved the removal of traumatic cataract including two eyes with significant zonular dehiscence treated by lens capsule conservation using anchoring devices, one retinal surgery and two glaucoma filtration surgeries. However, final visual outcome was not favorable due to irreversible retinal damage.
Conclusions: Paintball trauma often results in significant ocular injury and loss of functional vision despite successful surgical interventions. Most injuries are easily preventable and occur in under-supervised settings. Improved safety measures, strict regulation enforcement and appropriate public education could prevent such serious damage.
Avinoam Nevler MD, Esther Shabtai MD, Danny Rosin MD, Aviad Hoffman MD, Mordechai Gutman MD and Moshe Shabtai MD
Background: High density breast mammography has been associated with a greater risk for breast cancer and an increased likelihood of false negative results.
Objectives: To assess whether the degree of mammographic breast density correlates with an increased risk for the presence of radiographic findings requiring further histological investigation.
Methods: Included in the study were 2760 consecutive screening mammograms performed in a large volume, early detection mammography unit. All mammograms were complemented by high resolution ultrasound and interpreted by a single expert radiologist. Breast density (BD) was evaluated using a semi-quantitative 5 grade scale and grouped into low breast density (LBD) and high breast density (HBD) mammograms. Demographic and all relevant obstetric, personal and family history of breast cancer data were recorded.
Results: Of the 2760 mammograms 2096 (76%) were LBD and 664 (24%) were HBD. Mean age of the LBD and HBD groups was 59 ± 10.5 and 50.9 ± 9.3 years respectively (P = 0.001). Breast density significantly correlated with presence of mammographic findings requiring further histological assessment (8.7% and 12.3% for LBD and HBD respectively, P < 0.01). In women younger than 60 years in whom histological assessment was required due to these findings, malignant pathology was significantly more prevalent in the HBD group (2.3% and 4.1% respectively, P = 0.03). Age, parity, patient history and HBD were identified as independent risk factors for any pathological mammographic finding.
Conclusions: Highly dense mammography, aside from being an indicator of higher risk for breast cancer, appears to be associated with a significantly higher incidence of findings that will prompt further investigation to achieve a definite diagnosis.
Etty Daniel-Spiegel MD, Micha Mandel PhD, Daniel Nevo MA, Avraham Ben-Chetrit MD, Ori Shen MD, Eliezer Shalev MD and Simcha Yagel MD
Background: Selection of appropriate reference charts for fetal biometry is mandatory to ensure an accurate diagnosis. Most hospitals and clinics in Israel use growth curves from the United States. Charts developed in different populations do not perform well in the Israeli population.
Objectives: To construct new reference charts for fetal biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), using a large sample of fetuses examined at 14–42 weeks gestational age in a medical center and a community ultrasound unit located in two different regions of Israel.
Methods: Data from the medical center and the community clinic were pooled. The mean and standard error of each measure for each week was calculated. Based on these, reference charts were calculated using quantiles of the normal distribution. The performance of the reference charts was assessed by comparing the new values to empirical quantiles.
Results: Biometric measurements were obtained for 79,328 fetuses. Growth charts were established based on these measurements. The overall performance of the curves was very good, with only a few exceptions among the higher quantiles in the third trimester in the medical center subsample.
Conclusions: We present new local reference charts for fetal biometry, derived from a large and minimally selected Israeli population. We suggest using these new charts in routine daily obstetric practice.