August 2010
H. Danenberg, A. Finkelstein, R. Kornowski, A. Segev, D. Dvir, D. Gilon, G. Keren, A. Sagie, M. Feinberg, E. Schwammenthal, S. Banai, C. Lotan and V. Guetta

Background: The prevalence of aortic stenosis increases with advancing age. Once symptoms occur the prognosis in patients with severe aortic stenosis is poor. The current and recommended treatment of choice for these patients is surgical aortic valve replacement. However, many patients, mainly the very elderly and those with major comorbidities, are considered to be at high surgical risk and are therefore denied treatment. Recently, a transcatheter alternative to surgical AVR[1] has emerged.

Objectives: To describe the first year experience and 30 day outcome of transcatheter aortic self-expandable CoreValve implantation in Israel.

Methods: Transcatheter aortic valve implantation using the CoreValve system has been performed in Israel since September 2008. In the following year 55 patients underwent CoreValve TAVI[2] in four Israeli centers.

Results: Patients' mean age was 81.7 ± 7.1 years; there were 35 females and 20 males. The mean valve area by echocardiogram was 0.63 ± 0.16 cm2. The calculated mean logistic Euroscore was 19.3 ± 8%. Following TAVI, mean transvalvular gradient decreased from baseline levels of 51 ± 13 to 9 ± 3 mmHg. The rate of procedural success was 98%. One patient died on the first day post-procedure (1.8%) and all-cause 30 day mortality was 5.5% (3 of 55 patients). One patient had a significant post-procedural aortic regurgitation of > grade 2. Symptomatic improvement was evident in most patients, with reduction in functional capacity grade from 3.2 ± 0.6 at baseline to 1.4 ± 0.7. The most common post-procedural complication was complete heart block, which necessitated permanent pacemaker implantation in 37% of patients.

Conclusions: The Israeli first year experience of transcatheter aortic valve implantation using the CoreValve self-expandable system demonstrates an effective and safe procedure for the treatment of severe aortic stenosis in patients at high surgical risk.






[1] AVR = aortic valve replacement



[2] TAVI = transcatheter aortic valve implantation


F. Shibli, B. Chazan, O. Nitzan, E. Flatau, H. Edelstein, O. Blondheim, R. Raz and R. Colodner

Background: Community-acquired pneumonia is a common infection and is associated with high rates of morbidity and mortality. Most patients with CAP[1] are treated empirically.

Objectives: To identify common pathogens causing CAP in hospitalized patients in northern Israel and to evaluate the correlation between etiology and disease severity.

Methods: We conducted a prospective study of patients with CAP hospitalized at HaEmek Medical Center, Afula. We collected demographic, clinical and laboratory data (blood and sputum cultures, serology, pneumococcal urinary antigen test, and respiratory multiplex-polymerase chain reaction from nasopharyngeal swab), and radiologic evaluation was performed.

Results: A total of 126 patients and 24 controls were enrolled. At least one pathogen was identified in 84 cases (66.7%), more than one in 43 patients (34.1%), and no pathogens in 42 (33.3%). Typical bacteria were found in 23 (18.3%), atypical bacteria in 66 (52.4%), and viruses in 42 (33.3%). The number (%) of patients with pathogens isolated was: Chlamydophila pneumoniae 26 (20.6%), Streptococcus pneumoniae 23 (18.3%), Mycoplasma pneumoniae 23 (18.3%), influenza virus A-B 20 (15.9%), Coxiella burnetti 8 (6.3%), and parainfluenza and adenovirus 13 (10.3%) each. A correlation was found only between a high PORT score on admission and S. pneumoniae, although atypical pathogens did not show class predominance.

Conclusions: S. pneumoniae, M. pneumoniae and C. pneumoniae were the most common pathogens isolated, while co-infection was very frequent. PORT score did not predict any of the pathogens involved. The choice of empiric antimicrobial treatment for CAP should be made according to local epidemiologic data.






[1] CAP = community-acquired pneumonia


C. Vigder, Y. Ben Israel, S.R. Meisel, E. Kaykov, S. Gottlieb and A. Shotan

Background: Guidelines are frequently under-implemented in older patients with heart failure. Octogenerians are often excluded from clinical trials.

Objectives: To characterize the clinical profile of the oldest-old (age ≥ 80 years) heart failure patients hospitalized in a subacute geriatric hospital and to evaluate their management and 1 year outcome.

Methods: Patient characteristics and in-hospital course were retrospectively collected. Diagnosis of heart failure was based mainly on clinical evaluation in addition to chest X-ray results and echocardiographic findings when available.

Results: The study population comprised 96 consecutive unselected heart failure patients hospitalized from January to June 2003. The patients were predominantly women (67%), aged 85 ± 5 years, fully dependent or frail with a high rate of comorbidities. Adherence to guidelines and recommended heart failure medications was poor. Their 1 year mortality was 57%. According to logistic regression analysis, predictors of 1 year mortality were lower body mass index (odds ratio 0.86, 95% confidence interval 0.78–0.96) and high urea levels (OR[1] 1.04, 95% CI[2] 1.02–1.06).

Conclusions: Our study confirms that the management of oldest-old heart failure patients hospitalized in a subacute geriatric hospital was suboptimal and their mortality was exceptionally high.






[1] OR = odds ratio



[2] CI = confidence interval


J. Malyszko, H. Bachorzewska-Gajewska, J. Malyszko, N. Levin-Iaina, A. Iaina and S. Dobrzycki

Background: Kidney disease and cardiovascular disease seem to be lethally synergistic and both are approaching the epidemic level. A reduced glomerular filtration rate is associated with increased mortality risk in patients with heart failure. Many patients with congestive heart failure are anemic. Anemia is very often associated with chronic kidney disease.

Objectives: To assess – in relation to New York Heart Association class – the prevalence of anemia and chronic kidney disease in patients with normal serum creatinine in a cohort of 526 consecutive patients with coronary artery disease undergoing percutaneous coronary interventions.

Methods: GFR[1] was estimated using the simplified MDRD formula, the Cockcroft-Gault formula, the Jeliffe and the novel CKD-EPI formula.

Results: According to the WHO definition the prevalence of anemia in our study was 21%. We observed a progressive decline in GFR and hemoglobin concentration together with a rise in NYHA[2] class. Significant correlations were observed between eGFR[3] and systolic blood pressure, diastolic blood pressure, age, NYHA class, complications of PCI[4], including bleeding, and major adverse cardiac events.

Conclusions: The prevalence of anemia and chronic kidney disease is high in patients undergoing PCI despite normal serum creatinine, particularly in higher NYHA class. Lower eGFR and hemoglobin are associated with more complications, including bleeding after PCI and higher prevalence of major adverse cardiac events. In patients with risk factors for cardiovascular disease, GFR should be estimated since renal dysfunction and subsequent anemia are important risk factors for cardiovascular morbidity and mortality.






[1] GFR = glomerular filtration rate



[2] NYHA = New York Heart Association



[3] eGFR = estimated GFR



[4] PCI = percutaneous coronary intervention


R. Nevzorov, E. Shleyfer, A. Gourevitch, A. Jotkowitz, A. Porath and L. Barski
July 2010
O. Halshtok, O. Goitein, R. Abu Sham'a, H. Granit, M. Glikson and E. Konen
Background: Until recently, cardiac pacemakers and implantable cardioverter defibrillators were considered an absolute contraindication for magnetic resonance imaging. Given the significant increase in implanting such devices, these contraindications will preclude MRI scanning in a large patient population. Several recent reports have addressed the safety and feasibility of MRI in the presence of cardiac implantable devices.

Objectives: To summarize our experience with MRI scanning in the presence of pacemakers and implantable cardioverter defibrillators.

Methods: Eighteen patients (15 males and 3 females, median 59) were scanned using a 1.5 T MRI scanner. A clinical discussion was held to verify the absolute medical necessity of the study before performing the scan. Scan supervision included device interrogation and programming beforehand, patient monitoring during, and device interrogation and reprogramming after the scan. Full resuscitation equipment was available outside the MRI suite.

Results: Thirty-four scans were performed, and all but one were of diagnostic quality. Anatomic regions included the brain (N=26), cervical spine (N=2), lumbar spine (N=1), cardiac (N=2), abdomen (N=1), abdomen and pelvis (N=1) and pelvis (N=1). None of the patients reported any side effects and no life-threatening events occurred during or following the scans. Five cases of device spontaneous reversion to backup mode were recorded (four in the same patient). Device replacement was not required in any patient.

Conclusions: In this small cohort of patients MRI scanning in the presence of cardiac implantable devices was safe. MRI in these patients is feasible although not recommended for routine scans. Scans should be considered on a case-to-case basis and performed in a dedicated specialized setup.

 

L. Barski, R. Nevzorov, J. Horowitz and S. Horowitz

Background: Clinical and epidemiologic features of coronary heart disease may not be explained solely by established risk factors. The role of infectious pathogens in the development and rupture of atherosclerotic plaques remains elusive but an association between Chlamydia pneumoniae, Mycoplasma pneumoniae and CHD[1] has been previously reported

Objectives: To determine whether there is an association between mycoplasmal infections and CHD.

Methods: We conducted a prospective cohort analysis of 150 consecutive hospitalized patients with CHD (85 with acute coronary syndrome and 65 admitted for unrelated reasons) and 98 healthy blood donors. Antibody titers for Mycoplasma pneumoniae, M. fermentans, M. hominis and Ureaplasma urealyticum were measured with the agglutination test or specific enzyme-linked immunosorbent assay in all three groups of patients.

Results: Analysis of the antibody titers did not reveal any significant difference in the presence of mycoplasmal antibodies between the patients with ACS[2], patients with known stable CHD hospitalized for non-CHD reasons, and healthy blood donors.

Conclusions: Determination of specific antibodies did not reveal a significant association among different types of mycoplasmal infection and CHD.





[1] CHD = coronary heart disease

[2] ACS = acute coronary syndrome

M. Haddad, G. Rubin, M. Soudry and N. Rozen

Background: There is controversy as to which is the preferred treatment for distal radius intra-articular fractures – anatomic reduction or external fixation.

Objectives: To evaluate the radiologic and functional outcome following external fixation of these fractures.

Methods: Between January 2003 and March 2005, 43 patients with distal radius intra-articular fractures were treated using a mini-external AO device. Follow-up of 38 of the patients included X-rays at 1 week, 6 weeks and 6 months postoperatively. The Visual Analogue Scale was used to assess pain levels, and the Lidstrom criteria scale to evaluate functional outcome and wrist motion. Clinical and radiographic results were correlated.

Results: According to the Lidstrom criteria, the results were excellent in 31%, good in 61% and fair in 5.5%; 2.5% had a poor outcome. The results of the VAS[1] were good. Thirty-five patients gained a good range of wrist movement, but 3 had a markedly reduced range. We found statistical correlation between the radiographic and clinical results, emphasizing the value of good reduction. There was no correlation between fracture type (Frykman score) and radiologic results or clinical results.

Conclusions: External fixation seems to be the preferred method of treatment for distal radius intra-articular fractures, assuming that good reduction can be achieved. The procedure is also quick, the risk of infection is small, and there is little damage to the surrounding tissues.

 






[1] VAS = Visual Analogue Scale


D.I. Nassie, M. Berkowitz, M. Wolf, J. Kronenberg and Y.P. Talmi
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel