• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Thu, 18.07.24

Search results


October 2016
Michal M. Amitai MD, Eldad Katorza MD, Larisa Guranda MD, Sara Apter MD, Orith Portnoy MD, Yael Inbar MD, Eli Konen MD, Eyal Klang MD and Yael Eshet MD

Background: Pregnant women with acute abdominal pain pose a diagnostic challenge. Delay in diagnosis may result in significant risk to the fetus. The preferred diagnostic modality is magnetic resonance imaging (MRI), since ultrasonography is often inconclusive, and computed tomography (CT) would expose the fetus to ionizing radiation

Objectives: To describe the process in setting up an around-the-clock MRI service for diagnosing appendicitis in pregnant women and to evaluate the contribution of abdominal MR in the diagnosis of acute appendicitis.

Methods: We conducted a retrospective study of consecutive pregnant women presenting with acute abdominal pain over a 6 year period who underwent MRI studies. A workflow that involved a multidisciplinary team was developed. A modified MRI protocol adapted to pregnancy was formulated. Data regarding patients' characteristics, imaging reports and outcome were collected retrospectively. 

Results: 49 pregnant women with suspected appendicitis were enrolled. Physical examination was followed by ultrasound: when positive, the patients were referred for MR scan or surgery treatment; when the ultrasound was inconclusive, MR scan was performed. In 88% of women appendicitis was ruled out and surgery was prevented. MRI diagnosed all cases with acute appendicitis and one case was inconclusive. The overall statistical performance of the study shows a negative predictive value of 100% (95%CI 91.9–100%) and positive predictive value of 83.3% (95%CI 35.9–99.6%).

Conclusions: Creation of an around-the-clock imaging service using abdominal MRI with the establishment of a workflow chart using a dedicated MR protocol is feasible. It provides a safe way to rule out appendicitis and to avoid futile surgery in pregnant women.

Naseem Shadafny MD, Samuel N. Heyman MD, Michael Bursztyn MD, Anna Dinaburg MD, Ran Nir-Paz MD and Zvi Ackerman MD
September 2016
Doron Rimar MD, Itzhak Rosner MD, Gleb Slobodin MD, Michael Rozenbaum MD, Lisa Kaly MD, Nina Boulman MD and Zahava Vadasz MD
Dimosthenis Chochlakis MD, Elpis Mantadakis MD, Stavros Thomaidis MD, Yannis Tselenti MD, Athanassios Chatzimichael MD and Anna Psaroulaki MD
June 2016
Doron Goldberg MD MHA, Avi Tsafrir MD, Naama Srebnik MD, Michael Gal MD PhD, Ehud J. Margalioth MD, Pnina Mor CNM PHD, Rivka Farkash MPH, Arnon Samueloff MD and Talia Eldar-Geva MD PhD

Background: Fertility treatments are responsible for the rise in high order pregnancies in recent decades and their associated complications. Reducing the number of embryos returned to the uterus will reduce the rate of high order pregnancies.     

Objectives: To explore whether obstetric history and parity have a role in the clinician’s decision making regarding the number of embryos transferred to the uterus during in vitro fertilization (IVF).

Methods: In a retrospective study for the period August 2005 to March 2012, data were collected from twin deliveries > 24 weeks, including parity, mode of conception (IVF vs. spontaneous), gestational age at delivery, preeclampsia, birth weight, admission to the neonatal intensive care unit (NICU), and Apgar scores. 

Results: A total of 1651 twin deliveries > 24 weeks were recorded, of which 959 (58%) were at term (> 37 weeks). The early preterm delivery (PTD) rate (< 32 weeks) was significantly lower with increased parity (12.6%, 8.5%, and 5.6%, in women with 0, 1, and ≥ 2 previous term deliveries, respectively). Risks for PTD (< 37 weeks), preeclampsia and NICU admission were significantly higher in primiparous women compared to those who had one or more previous term deliveries. Primiparity and preeclampsia, but not IVF, were significant risk factors for PTD. 

Conclusions: The risk for PTD in twin pregnancies is significantly lower in women who had a previous term delivery and decreases further after two or more previous term deliveries. This finding should be considered when deciding on the number of embryos to be transferred in IVF.  

 

Einat Hertzberg-Bigelman MsC, Rami Barashi MD, Ran Levy PhD, Lena Cohen MSc, Jeremy Ben-Shoshan MD PhD, Gad Keren MD and Michal Entin-Meer PhD

Background: Chronic kidney disease (CKD) is often accompanied by impairment of cardiac function that may lead to major cardiac events. Erythropoietin (EPO), a kidney-produced protein, was shown to be beneficial to heart function. It was suggested that reduced EPO secretion in CKD may play a role in the initiation of heart damage. 

Objectives: To investigate molecular changes in the EPO/erythropoietin receptor (EPO-R) axis in rat cardiomyocytes using a rat model for CKD.

Methods: We established a rat model for CKD by kidney resection. Cardiac tissue sections were stained with Masson’s trichrome to assess interstitial fibrosis indicating cardiac damage. To evaluate changes in the EPO/EPO-R signaling cascade in the myocardium we measured cardiac EPO and EPO-R as well as the phosphorylation levels of STAT-5, a downstream element in this cascade.

Results: At 11 weeks after resection, animals presented severe renal failure reflected by reduced creatinine clearance, elevated blood urea nitrogen and presence of anemia. Histological analysis revealed enhanced fibrosis in cardiac sections of CKD animals compared to the sham controls. Parallel to these changes, we found that although cardiac EPO levels were similar in both groups, the expression of EPO-R and the activated form of its downstream protein STAT-5 were significantly lower in CKD animals.

Conclusions: CKD results in molecular changes in the EPO/EPO-R axis. These changes may play a role in early cardiac damage observed in the cardiorenal syndrome.

 

Ely L. Steinberg MD, Eitan Segev MD, Michael Drexler MD, Tomer Ben-Tov MD and Snir Nimrod MD

The progression from standard celluloid films to digitalized technology led to the development of new software programs to fulfill the needs of preoperative planning. We describe here preoperative digitalized programs and the variety of conditions for which those programs can be used to facilitate preparation for surgery. A PubMed search using the keywords “digitalized software programs”, “preoperative planning” and “total joint arthroplasty” was performed for all studies regarding preoperative planning of orthopedic procedures that were published from 1989 to 2014 in English. Digitalized software programs are enabled to import and export all picture archiving communication system (PACS) files (i.e., X-rays, computerized tomograms, magnetic resonance images) from either the local working station or from any remote PACS. Two-dimension (2D) and 3D CT scans were found to be reliable tools with a high preoperative predicting accuracy for implants.  The short learning curve, user-friendly features, accurate prediction of implant size, decreased implant stocks and low-cost maintenance makes digitalized software programs an attractive tool in preoperative planning of total joint replacement, fracture fixation, limb deformity repair and pediatric skeletal disorders.

Michal Fertouk MD, Shahar Grunner MD, Zvi Peled MD, Zvi Adler MD, Oz M. Shapira MD and Gil Bolotin MD PhD
May 2016
Keren Kremer MD, Michal Dekel MD, Avi Gadoth MD, Jacob Giris MD DSc and Jacob N. Ablin MD
February 2016
Michal Laufer Perl MD, Ariel Finkelstein MD, Miri Revivo MHA, Shlomo Berliner MD, Itzhak Herz MD, Itay Rabinovich MD, Tomer Ziv-Baran PhD, Dalit Gotler, Gad Keren MD, Shmuel Bana MD and Yaron Arbel MD

Background: Atherosclerosis is a systemic disease. Nevertheless, the role of specific biomarkers as indicators for both coronary and carotid diseases is debatable.

Objectives: To evaluate the association of biomarkers with coronary and carotid disease.

Methods: We studied 522 consecutive patients with stable angina. All underwent coronary angiography and carotid duplex study on the same day. Patients with no apparent carotid plaques were evaluated for carotid intima-media thickness (CIMT) using an automated system that sampled over 100 samples in each carotid artery. Biochemical markers of cardiovascular disease risk were obtained at the time of coronary angiography, including serum lipid levels, hemoglobin A1C (HbA1c), white blood cell count, fibrinogen and high sensitivity C-reactive protein (hs-CRP).

Results: The mean age of the patients was 66 ± 11; 73% were males. Significant carotid stenosis was associated with higher hs-CRP (9.4 ± 17 vs. 6.3 ± 13 mg/L, P = 0.001), while high HbA1c (6.7 ± 1.6 vs. 5.8 ± 0.8%, P < 0.001) and low high density lipoprotein levels (40 ± 9 vs. 47 ± 14 mg/dl, P < 0.001) were linked with advanced coronary artery disease severity. In contrast, CIMT was not related to any of the biomarkers evaluated.

Conclusions: Although atherosclerosis is considered a systemic disease, different biomarkers are associated with coronary and carotid artery disease. Identifying the specific biomarkers for each disease is important for both prevention and for exposing the underlying pathophysiologic mechanism.

 

Alisher Tashbayev MD, Alexander Belenky MD, Sergey Litvin MD, Michael Knizhnik MD, Gil N. Bachar MD and Eli Atar MD

Background: Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). 

Objectives: To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature.

Methods: During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complications rate were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature.

Results: Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18–99) and was noted to be significantly higher compared to similar studies (53–56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. 

Conclusions: In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.

 

Avi Moscovici MD, Michael Kogan MD, Iris Kliers MD, Olga Kukuy MD and Gad Segal MD
January 2016
Amir Givon MD, Natalia Vedernikova MD, David Luria MD, Ori Vatury MD, Rafael Kuperstein MD, Micha S. Feinberg MD, Michael Eldar MD, Michael Glikson MD and Eyal Nof MD

Background: Transvenous lead extraction can lead to tricuspid valve damage. 

Objectives: To assess the incidence, risk factors and clinical outcome of tricuspid regurgitation (TR) following lead extraction.

Methods: We prospectively collected data on patients who underwent lead extraction at the Sheba Medical Center prior to laser use (i.e., before 2012). Echocardiography results before and following the procedure were used to confirm TR worsening, defined as an echocardiographic increase of at least one TR grade. Various clinical and echocardiographic parameters were analyzed as risk factors for TR. Clinical and echocardiographic follow-up was conducted to assess the clinical significance outcome of extraction-induced TR.

Results: Of 152 patients who underwent lead extraction without laser before 2012, 86 (56%) (192 electrodes) had echocardiography results before and within one week following the procedure. New or worsening TR was discovered in 13 patients (15%). Use of mechanical tools and younger age at extraction were found on multivariate analysis to be factors for TR development (P = 0.04 and P = 0.03 respectively). Average follow-up was 22.25 ± 21.34 months (range 8–93). There were no significant differences in the incidence of right-sided heart failure (50% vs. 23%, P = 0.192) or hospitalizations due to heart failure exacerbations (37.5% vs. 11%, P = 0.110). No patient required tricuspid valve repair or replacement. Death rates were similar in the TR and non-TR groups (20% vs. 33%).

Conclusions: TR following lead extraction is not uncommon but does not seem to affect survival or outcomes such as need for valve surgery. Its long-term effects remain to be determined. 

 

Etty Daniel-Spiegel MD, Micha Mandel PhD, Daniel Nevo MA, Avraham Ben-Chetrit MD, Ori Shen MD, Eliezer Shalev MD and Simcha Yagel MD

Background: Selection of appropriate reference charts for fetal biometry is mandatory to ensure an accurate diagnosis. Most hospitals and clinics in Israel use growth curves from the United States. Charts developed in different populations do not perform well in the Israeli population.

Objectives: To construct new reference charts for fetal biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), using a large sample of fetuses examined at 14–42 weeks gestational age in a medical center and a community ultrasound unit located in two different regions of Israel. 

Methods: Data from the medical center and the community clinic were pooled. The mean and standard error of each measure for each week was calculated. Based on these, reference charts were calculated using quantiles of the normal distribution. The performance of the reference charts was assessed by comparing the new values to empirical quantiles.

Results: Biometric measurements were obtained for 79,328 fetuses. Growth charts were established based on these measurements. The overall performance of the curves was very good, with only a few exceptions among the higher quantiles in the third trimester in the medical center subsample.

Conclusions: We present new local reference charts for fetal biometry, derived from a large and minimally selected Israeli population. We suggest using these new charts in routine daily obstetric practice.

 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel