November 2020
Hezzy Shmueli MD, Arie Steinvil MD, Galit Aviram MD, Sileman Moaad MD, Adam Sharon MD, Achiude Bendet MD, Simon Biner MD, Yacov Shacham MD, Jack Sherez MD, Ricki Megidish MD, Yifat Hasin MD, Ester Elazar MD, Sevan Letourneau-Shesaf MD, Gad Keren MD ,Shlomo Berliner MD, and Yan Topilsky MD

Background: Acute pulmonary embolism (PE) is considered to be one of the most common cardiovascular diseases with considerable mortality. Conflicting data imply possible role for echocardiography in assessing this disease.

Objectives: To determine which of the echo parameters best predicts short-term and long-term mortality in patients with PE.

Methods: We prospectively enrolled 235 patients who underwent computed tomography of pulmonary arteries (CTPA) and transthoracic Echocardiography (TTE) within < 24 hours. TTE included a prospectively designed detailed evaluation of the right heart including right ventricular (RV) myocardial performance index (RIMP), RV end diastolic and end systolic area, RV fractional area change, acceleration time (AT) of pulmonary flow and visual estimation. Interpretation and performance of TTE were blinded to the CTPA results.

Results: Although multiple TTE parameters were associated with PE, all had low discriminative capacity (AUC < 0.7). Parameters associated with 30-day mortality in univariate analysis were acceleration time (AT) < 81 msec (P = 0.04), stroke volume < 44 cc (P = 0.005), and RIMP > 0.42 (P = 0.05). The only RV independent echo parameter associated with poor long-term prognosis (adjusted for significant clinical, and routine echo associates of mortality) was RIMP (hazard ratio 3.0, P = 0.04). The only independent RV echo parameters associated with mortality in PE patients were RIMP (P = 0.05) and AT (P = 0.05). Addition of RIMP to nested models eliminated the significance of all other parameters assessing RV function.

Conclusions: Doppler-based parameters like pulmonary flow AT, RIMP, and stroke volume, have additive value in addition to visual RV estimation to assess prognosis in patients with PE.

October 2015
March 2015
Olga Reitblat MD, Tsahi T. Lerman MD, Olga Grisko MD, Anna Gelfand MD, Azaria Simonovich MD, Galina Novokhatko MD, Doron Zamir MD and Tatiana Reitblat MD
June 2008
D. Sharif, G. Rofe, A. Sharif-Rasslan, E. Goldhammer, N. Makhoul, A. Shefer, A. Hassan, S. Rauchfleisch and U. Rosenschein

Background The temporal behavior of the coronary microcirculation in acute myocardial infarction may affect outcome. Diastolic deceleration time and early systolic flow reversal derived from coronary artery blood flow velocity patterns reflect microcirculatory function.

Objectives To assess left anterior descending coronary artery flow velocity patterns using Doppler transthoracic echocardiography after primary percutaneous coronary intervention, in patients with anterior AMI[1].

Methods Patterns of flow velocity patterns of the LAD[2] were obtained using transthoracic echocardiography-Doppler in 31 consecutive patients who presented with anterior AMI. Measurements were done at 6 hours, 36–48 hours, and 5 days after successful PPCI[3]. Measurements of DDT[4] and pressure half times (Pt½), as well as observation for ESFR[5] were performed.

Results In the first 2 days following PPCI, the average DDT, 600 ± 340 msec, were shorter than on day 5, 807 ± 332 msec (P < 0.012). FVP[6] in the first 2 days were dynamic and bidirectional: from short DDT (< 600 msec) to long DDT (> 600 msec) and vice versa. On day 5 most DDTs became longer. Pt½ at 6 hours was not different than at day 2 (174 ± 96 vs. 193 ± 99 msec, P = NS) and became longer on day 5 (235 ± 98 msec, p = 0.012). Bidirectional patterns were also observed in the ESFR in 6 patients (19%) at baseline, in 4 (13%) at 36 hours, and in 2 (6.5%) on day 5 after PPCI.






[1] AMI = acute myocardial infarction

[2] LAD = left anterior descending

[3] PPCI = primary percutaneous coronary intervention

[4] DDT = diastolic deceleration time

[5] ESFR = early systolic flow reversal  

[6] FVP = flow velocity pattern


October 2007
V. Rathaus and M. Werner

Background: Acute focal nephritis is an inflammatory process of the renal parenchyma affecting principally the cortex of the kidney. It is considered a midpoint in the spectrum of upper urinary tract infections, ranging from uncomplicated pyelonephritis to intrarenal abscesses, and until recently the hyperechoic sonographic appearance of this lesion was considered uncommon.  

Objectives: To determine the relative prevalence of hyperechoic and hypoechoic sonographic appearance of focal renal lesions in patients with the clinical diagnosis of acute pyelonephritis and to correlate the findings with those of the color Doppler examinations.

Methods: We reviewed the sonograms of 367 patients hospitalized with the clinical diagnosis of acute pyelonephritis. The sonograms were reviewed for acute renal inflammatory changes. When a focal lesion was detected, we noted the echogenicity, side, form, location and color Doppler characteristics.

Results: Abnormal sonographic findings related to the infection were found in 78 cases. In 52 patients a focal lesion was diagnosed. Forty-seven focal lesions appeared hyperechoic related to the adjacent parenchyma. These lesions were more frequently located at the upper pole and were wedge-shaped in most of the cases. The areas appeared hypo/avascular on the color Doppler examination.

Conclusions: Our data suggest that the most common appearance of acute focal nephritis is an area of increased echogenicity in the parenchyma of the affected kidney.
 

February 2007
N. Slijper,,I. Sukhotnik, A. urora Toubi, J. Mogilner

Background: Testicular torsion associated with undescended testis is uncommon but requires immediate treatment. Ultrasound Doppler is recognized as the preferred imaging modality for testicular torsion due to its high specificity, sensitivity and availability.

Objectives: To determine the accuracy of ultrasound Doppler in diagnosis of torsion of undescended testis.

Methods: We describe three patients with known undescended testis who were admitted with groin pain and had preoperative ultrasound Doppler. The discrepancy between these and the intraoperative findings is discussed.

Results: In two patients incarcerated inguinal hernia was diagnosed with ultrasound Doppler; however, surgery revealed torsion of an undescended testis. In the third patient ultrasound Doppler diagnosed torsion of undescended testis, but at surgery incarcerated inguinal hernia was found, without evidence of testicular torsion.

Conclusions: Torsion of undescended testis should be a clinical rather than radiologic diagnosis.
 

November 2005
N. Sharon, J. Schachter, R.T. Talnir, J. First, U. Rubinstein and R. Bilik
February 2004
Y. Schwammenthal, M.J. Drescher, O. Merzeliak, R. Tsabari, B. Bruk, M. Feibel, C. Hoffman, M. Bakon, Z. Rotstein, J. Chapman and D. Tanne

Background: Intravenous recombinant tissue plasminogen activator therapy within 3 hours of stroke onset is a proven effective treatment for acute ischemic stroke.

Objectives: To assess the feasibility and safety of rt-PA[1] therapy for reperfusion in routine clinical practice in Israel, in a setting of a dedicated stroke unit.

Methods: Consecutive patients presenting within less than 3 hours of stroke onset were evaluated by an emergency physician and the neurology stroke team. After brain computerized tomography eligible patients were treated with intravenous rt-PA (0.9 mg/kg; maximum dose 90 mg) according to an in-hospital protocol corresponding to recommended criteria. Patients were admitted to the acute stroke unit. Safety and clinical outcome were routinely assessed. Re-canalization was assessed by serial transcranial Doppler.

Results: The study group comprised 16 patients, mean age 61 years (range 47–80 years), male to female ratio 10:6, whose median baseline National Institutes of Health stroke scale was 13 (range 6–24). They were treated within a mean door-to-CT time of 39 minutes (range 17–62 min), door-to-drug time 101 minutes (range 72–150), and stroke onset-to-drug time 151 minutes (range 90–180). There was an early improvement within 24 hours (of ≥ 4 points in the NIHSS[2] score) in 7 patients (44%) and no early deteriorations. There were no protocol deviations, no symptomatic intracranial hemorrhages, and no major systemic hemorrhage within 36 hours of rt-PA treatment. Three asymptomatic hemorrhagic transformations of the infarct were noted on routine follow-up brain CT associated with neurologic improvement. Outcome data were comparable to the National Institute of Neurological Disorders and Stroke rt-PA Stroke Study.

Conclusion: Intravenous rt-PA treatment within 3 hours of stroke onset in routine clinical practice in Israel is feasible and appears safe in the setting of a neurology stroke unit and team. Careful implementation of rt-PA therapy for selected patients in Israel is encouraged.






[1] rt-PA = recombinant tissue plasminogen activator



[2] NIHSS = National Institutes of Health stroke scale


January 2004
N. Hod, Z Maizlin, S. Strauss and T. Horne

Background: Since the early 1970s testicular scintigraphy has been used to diagnose the cause of acute scrotal pain. The advent of Doppler sonography further enhances diagnosis by  providing simultaneous real-time scrotal imaging with superimposed testicular blood flow information.

Objectives: To assess the diagnostic value of Doppler sonography in patients with acute scrotal pain and scintigraphic findings suggestive of testicular torsion.

Methods: Seventy-five patients with acute scrotal pain underwent testicular scintigraphy and Doppler sonography. All patients who had scintigraphic findings suggestive of testicular torsion were included in the study and their files were retrospectively reviewed.

Results: Twenty-seven patients had scintigraphic findings suggestive of testicular torsion. Radionuclide scintigraphy accurately detected all cases of testicular torsion. However, abscess, hematoma, hydrocele and other conditions simulated testicular torsion on scintigraphy, lowering the test specificity. These pathologies were clarified by Doppler sonography that was 95% specific and 86% sensitive for testicular torsion.

Conclusions: Doppler sonography should be used as the first-line modality in the evaluation of patients with suspected testicular torsion. Scintigraphy should be performed only in certain settings of equivocal sonographic findings to prevent false negative sonographic diagnosis.
 

December 2003
G.N. Bachar, A. Belensky, F. Greif, E. Atar, Y. Gat, M. Itkin and A. Verstanding

Background: Ovarian vein embolization was recently suggested as the preferred treatment for chronic pelvic pain syndrome.

Objective: To evaluate the technical feasibility, complications and early clinical and radiographic results of ovarian vein embolization in women with pelvic pain syndrome.

Methods: Percutaneous transcatheter ovarian vein embolization with coils was performed in six patients aged 27–53 years who presented with pelvic pain syndrome. All had lower abdominal pain, and pelvic varicosities were found on Doppler ultrasound and retrograde ovarian vein venography. Embolization was done unilaterally in three patients (on the left side) and bilaterally in three. Mean follow-up by telephone questionnaire was 7.3 months.

Results: The procedure was technically successful in all patients. Two patients reported partial relief of symptoms (33.3%) and three had complete relief (50%), for a total of 5 patients (83.3%) with some measure of improvement. There were no complications following the procedure.

Conclusions: Percutaneous transcatheter ovarian vein embolization seems to be safe and feasible for the treatment of pelvic pain syndrome. The procedure is performed on an outpatient basis and is well tolerated by patients.