• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sun, 24.11.24

Search results


December 2023
Ron Ben Elyahu MD, Basel Khateeb MD, Eyal Yaacobi MD, Ezequiel Palmanovich MD, Omer Marom MD, David Segal MD, Michael Markushevich MD, Nissim Ohana MD, Yaron S. Brin MD

Background: Hip fractures are a public health problem that disproportionately affects the elderly. Displaced femoral neck fractures were treated historically with hemiarthroplasty, but the use of total hip arthroplasty (THA) is increasing showing superior long-term results.

Objectives: To assess whether THA has superior short-term results compared to bipolar hemiarthroplasty for displaced femoral neck fractures.

Methods: Two groups of active older patients underwent either cementless bipolar hemiarthroplasty or THA for displaced femoral neck fracture. All patients were operated on using the direct lateral approach to the hip joint. Patients were assessed using the Harris Hip Score at hospital discharge and at 6 weeks follow-up.

Results: We included 40 patients ages 65–85 years; 18 underwent bipolar hemiarthroplasty and 22 THA. The number of women in each group was similar, as was mean age: 73.1 ± 4.2 years in the hemiarthroplasty group and 71.0 ± 3.7 in THA. Harris Hip Score on hospital discharge was similar in both groups. Walking ability at discharge was better in the THA cohort and they were discharged sooner: 5.2 ± 1.3 vs. 6.4 ± 1.7 days following hemiarthroplasty (P = 0.021). At 6 weeks follow-up, the mean Harris Hip Score was higher in the THA group (78.6 ± 11 vs. 61.5 ± 17 for hemiarthroplasty, P < 0.001). Patients in the THA group walked longer distances, needed less support while walking, and reported less pain.

Conclusions: Better short-term results at hospital discharge and at 6 weeks follow-up after THA contributed to earlier patient independence and shorter hospital stays.

August 2023
Michal M. Amitai MD, Nadin Kanaan MD, Shelly Soffer MD, Lee Alper, Noa Rozendorn MD, Daniel Jacob Harrington, Uri Kopylov MD, Adi Lahat MD, Doron Yablecovitch MD, Rami Eliakim MD, Shomron Ben-Horin MD, Eyal Klang MD

Background: Jejunal disease is associated with worse prognosis in Crohn's disease. The added value of diffusion weighted imaging for evaluating jejunal inflammation related to Crohn's Disease is scarce.

Objectives: To compare diffusion weighted imaging, video capsule endoscopy, and inflammatory biomarkers in the assessment of Crohn's disease involving the jejunum.

Methods: Crohn's disease patients in clinical remission were prospectively recruited and underwent magnetic resonance (MR)-enterography and video capsule endoscopy. C-reactive protein and fecal-calprotectin levels were obtained. MR-enterography images were evaluated for restricted diffusion, and apparent diffusion coefficient values were measured. The video capsule endoscopy-based Lewis score was calculated. Associations between diffusion weighted imaging, apparent diffusion coefficient, Lewis score, and inflammatory biomarkers were evaluated.

Results: The study included 51 patients, and 27/51 (52.9%) with video capsule endoscopies showed jejunal mucosal inflammation. Sensitivity and specificity of restricted diffusion for video capsule endoscopy mucosal inflammation were 59.3% and 37.5% for the first reader, and 66.7% and 37.5% for the second reader, respectively. Diffusion weighted imaging was not statistically associated with jejunal video capsule endoscopy inflammation (P = 0.813).

Conclusions: Diffusion weighted imaging was not an effective test for evaluation of jejunal inflammation as seen by video capsule endoscopy in patients with quiescent Crohn's disease.

August 2022
Anton Bermont MD, Daniel L Cohen MD, Vered Richter MD, Efrat Broide MD, and Haim Shirin MD

Background: One of the main causes of iron deficiency anemia (IDA) is chronic gastrointestinal blood loss. The use of video capsule endoscopy (VCE) after negative bidirectional endoscopy in patients with IDA is controversial.

Objectives: To evaluate the effect of VCE in the management and long-term outcomes of IDA patients.

Methods: A retrospective case-control study was performed on all patients with IDA undergoing VCE over a 5-year period. We compared those with positive findings on VCE to those with normal findings. All participants previously underwent a negative bidirectional endoscopy

Results: We performed 199 VCE examinations; median follow-up time was 4 years (IQR 2–5). Positive findings were identified in 66 patients (diagnostic yield 33.2%). Double balloon enteroscopy or push enteroscopy was performed in eight patients (18.6%); only one was therapeutic. The main therapy in both groups was iron supplementation. There were no significant differences in iron treatment before and after VCE in each group and between groups. Anemia improved in both groups. There was no difference in the level of hemoglobin change between the groups during each year of follow-up compared to the baseline level prior to VCE. Anemia resolved in 15 patients (35%) in the positive VCE group and in 19 (45%) in the negative VCE group (P = 0.33).

Conclusions: Positive findings on VCE led to subsequent endoscopic interventions only in a small percentage of patients with IDA. Anemia improved and resolved equally whether or not there were VCE findings. The main intervention that appears to help IDA is iron supplementation.

November 2021
Elizaveta Kouniavski MD, Eran Hadad MD, and Lior Heller MD

Background: Breast implant illness (BII) is a rising concern among many patients. Although not fully understood, a connection between silicone breast implants and systemic diseases may be present. This connection may influence the types of breast surgeries performed.

Objectives: To evaluate changing trends in breast surgeries in Israel over time, with regard to implantation, explantation, and implant exchange surgeries.

Methods: In this ecological study, we presented data from four private medical centers in Israel regarding the number of breast implant surgeries performed in the years 2018–2019. Data were collected bi-yearly. The types of surgeries included breast implantation, explantation, and breast implant exchange.

Results: When we summed and compared the yearly data, we saw that the number of implantations in 2018 was 2267 (80.1% of breast implant procedures that year), and 1929 (68.9%) in 2019. The number of implant exchanges in 2018 and 2019 was 482 (17.0%) and 608 (21.7%), respectively. In 2018, 80 (2.8%) explantations were performed and 262 (9.4%) in 2019.

Conclusions: There appears to be a trend in the rise of implant removal surgeries in addition to a decrease in breast implantations. One possible reason may be patient concerns of BII. Another reason may be the increased public interest and discussion about systemic effects of breast implants. More research is needed in this field to achieve better understanding of the phenomenon, the reasons behind it, and the possible solutions and ways of treatment

February 2020
June 2017
Ohad Ben-Nun MD, Nir Bitterman MD, Tamar Tadmor MD, Jacob Bejar MD, Adel Shalata MD, PhD , Hadid Yarin PhD and Noam Calderon MD
September 2016
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel