• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sat, 23.11.24

Search results


June 2024
Yuval Avidan MD, Amir Aker MD, Vsevolod Tabachnikov MD

Late arrival ST-segment elevation myocardial infarction (STEMI) is defined as a patient-related delay > 12 hours. It is estimated to represent a significant portion of STEMI patients. As reflected by society guidelines, this group of patients impose great therapeutic challenge, namely due to controversy in the literature regarding optimal care, together with major adverse clinical outcomes [1]. In addition to a possible myocardial infarction (MI), mechanical complications include ventricular septal defect (VSD), left ventricular (LV) free wall, or papillary muscle rupture. Prompt diagnosis and intervention are crucial to improve outcomes as post-infarction ventricular septal defect (PIVSD) carries a high mortality rate. We describe the successful management of a large VSD complicated by cardiogenic shock in a latecomer STEMI patient with complex coronary artery disease (CAD).

November 2023
Gassan Moady MD, Moanis Serhan MD, Shaul Atar MD, Alexander Shturman MD

Background: The continuity equation (CE) used for evaluating aortic stenosis (AS) is based on values obtained from transthoracic echocardiography (TTE) with the assumption that the left ventricular outflow tract (LVOT) has a circular shape. Transesophageal echocardiography (TEE) may be used for accurate measurement of the LVOT cross-sectional area (CSA). Previous studies have focused on fusion from TEE for LVOT-CSA measurement and TTE for velocity time integrals (VTI) calculations.

Objectives: To assess aortic valve area (AVA) using parameters obtained exclusively from TEE as an alternative approach.

Methods: Thirty patients with equivocal AS based on TTE were evaluated using TEE for further assessment.

Results: The mean pressure gradient across the aortic valve (AV) was 38 ± 5.9 and 37.9 ± 7.6 mmHg in TTE and TEE, respectively, P = 0.42. LVOT-CSA was larger in TEE (3.6 ± 0.3 vs. 3.4 ± 0.3 cm2, P = 0.049). VTI over the AVA was similar (98.54 ± 22.8 and 99.52 ± 24.52 cm in TTE and TEE, respectively, P = 0.608), while VTI across the LVOT was higher when measured by TTE (24.06 ± 5.8 vs. 22.03 ± 4.3 cm, P < 0.009). Using the CE, AVA was 0.82 ± 0.3 vs. 0.83 ± 0.17 cm2 in TEE vs. TTE, respectively, P = 0.608. Definitive grading was achieved in all patients (26 patients defined with severe AS and 4 with moderate).

Conclusions: In equivocal cases of AS, full assessment using TEE may be a reliable modality for decision making.

August 2023
Maya Shina MD, Fabio Kusniec MD, Guy Rozen MD MHA, Shemy Carasso MD FESC FASE, David Planer MD, Ronny Alcalai MD, Liza Grosman-Rimon PhD, Gabby Elbaz-Greener MD MHA DRCPSC, Offer Amir MD FACC

Background: Among the most frequent complications following transcatheter aortic valve replacement (TAVR) is hemostasis imbalance that presents either as thromboembolic or bleeding. Deviations in platelet count (PC) and mean platelet volume (MPV) are markers of hemostasis imbalance.

Objectives: To determine the predictive value of pre- and post-procedural PC and MPV fL 1-year all-cause mortality in patients who underwent TAVR.

Methods: In this population-based study, we included 236 TAVR patients treated at the Tzafon Medical Center between 1 June 2015 and 31 August 2018. Routine blood samples for serum PC levels and MPV fL were taken just before the TAVR and 24-hour post-TAVR. We used backward regression models to evaluate the predictive value of PC and MPV in all-cause mortality in TAVR patients.

Results: In this study cohort, MPV levels 24-hour post-TAVR that were greater than the cohort median of 9 fL (interquartile range 8.5–9.8) were the strongest predictor of 1-year mortality (hazard ratio 1.343, 95% confidence interval 1.059–1.703, P-value 0.015). A statistically significant relationship was seen in the unadjusted regression model as well as after the adjustment for clinical variables.

Conclusions: Serum MPV levels fL 24-hour post-procedure were found to be meaningful markers in predicting 1-year all-cause mortality in patients after TAVR.

Roy Bitan MD, Ophir Freund MD, David Zeltser MD, Sivan Ebril MD

Acute or chronic aortic dissection is considered a rare emergency, with an estimated rate of 2.9 to 5 cases per 100,000 patients each year. This condition is most prevalent in males older than 65 years of age with a history of hypertension, atherosclerosis, and previous cardiac surgery [1,2]. To confirm the diagnosis, imaging is used, often by computed tomography angiography (CTA) of the chest. Although prompt treatment is required, patients often present with non-specific symptoms, such as abdominal pain or neurologic deficits, resulting in the early diagnosis of less than 20% and a high mortality rate [1].

April 2022
Ilan Merdler MD MHA, Shir Frydman MD, Svetlana Sirota MSc, Amir Halkin MD, Arie Steinvil MD, Ella Toledano MD, Maayan Konigstein MD, Batia Litmanowicz MD, Samuel Bazan MD, Atalia Wenkert BA, Sapir Sadon BA, Shmuel Banai MD, Ariel Finkelstein MD, and Yaron Arbel MD

Background: Neutrophil-to-lymphocyte ratio (NLR) is a simple and cost-effective marker of inflammation. This marker has been shown to predict cardiac arrhythmias, progression of valvular heart disease, congestive heart failure decompensation, acute kidney injury, and mortality in cardiovascular patients. The pathologic process of aortic stenosis includes chronic inflammation of the valve and therefore biomarkers of inflammation might offer additive prognostic value.

Objectives: To evaluate NLR and its association with long term mortality in transcatheter aortic valve implantation (TAVI) patients.

Methods: We evaluated data of 1152 consecutive patient from the Tel Aviv Medical Center TAVI registry who underwent TAVI. Data included baseline clinical, demographic, and echocardiographic findings; procedural complications; and post-procedure mortality. Patients were compared by using the median NLR value (4.1) and evaluated for long-term mortality.

Results: Patients with NLR above the median had higher mortality rates (26.4% vs. 16.3%, P < 0.001) at 3 years post-procedure. A multivariable analysis found NLR to be an independent risk factor for mortality (hazard ratio = 1.47, 95% confidence interval 1.09–1.99, P = 0.013). In addition, high NLR was linked to complicationsduring and after the procedure.

Conclusion: NLR is an independent prognostic marker among TAVI patients. This marker may represent an increased inflammatory response and should be added to previous known prognostic factors.

March 2022
Israel Mazin MD, Ori Vaturi MD, Rafael Kuperstein MD, Roy Beigel MD, Micha Feinberg MD, and Sagit Ben Zekry MD

Background: Estimated frequency of aortic stenosis (AS) in those over 75 years of age is 3.4%. Symptomatic patients with severe AS have increased morbidity and mortality and aortic valve replacement should be offered to improve life expectancy and quality of life.

Objectives: To identify whether systolic time intervals can identify severe AS.

Methods: The study comprised 200 patients (mean age 79 years, 55% men). Patients were equally divided into normal, mild, moderate, or severe AS. All patients had normal ejection fraction. Acceleration time (AT) was defined as the time from the beginning of systolic flow to maximal velocity; ejection time (ET) was the time from onset to end of systolic flow. The relation of AT/ET was calculated. Death or aortic valve intervention were documented.

AT increased linearly with the severity of AS, similar to ET and AT/ET ratio (P for trend < 0.05 for all). Receiver-operator characteristic curve analysis demonstrated that AT can identify severe AS with a cutoff ≥ 108 msec with 100% sensitivity and 98% specificity, while a cutoff of 0.34 when using AT/ET ratio can identify severe AS with 96% sensitivity and 94% specificity. Multivariate analysis adjusting to sex, stroke volume index, heart rate, and body mass index showed similar results. Kaplan-Meier curve for AT ≥ 108 and AT/ET ≥ 0.34 predicted death or aortic valve intervention in a 3-year follow-up.

Conclusions: Acceleration time and AT/ET ratio are reliable measurements for identifying patients with severe AS. Furthermore, AT and AT/ET were able to predict aortic valve replacement or death

Lian Bannon MD, Omer Shlezinger MD, Alexandra Nathan MD, Yan Topilsky MD, Ilan Merdler MD MHA, and Eihab Ghantous MD
April 2021
Maged Makhoul MD, Roberto Lorusso MD, Elham Bidar MD, Rashad Zayad MD, and Ehsan Natour MD
April 2020
Yael Peled MD, Eilon Ram MD and Yehuda Shoenfeld MD FRCP MACR

The innovation that has taken place in medicine, combined with state-of-the-art technological developments, provides therapeutic options for patients in conditions that were previously considered incurable. This promotion at the same time presents us with new ethical challenges. In this article, we review the journey through life of an advanced heart failure patient, covering a variety of potential clinical and ethics subjects in the field of heart failure treatment. We review the ethical principles of the Hippocratic Oath against the background of the realities of practicing medicine and of the enormous advances in therapeutics.  

January 2020
Daniel Silverberg MD, Ahmad Abu Rmeileh MD, Daniel Raskin MD, Uri Rimon MD and Moshe Halak MD

Background: Endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAA) is associated with decreased perioperative morbidity and mortality.

Objectives: To report the outcomes of EVAR among patients older than 80 years of age.

Methods: In this retrospective study, we reviewed patients older than 80 years of age who underwent elective EVAR at our institution between 2007 and 2017. The demographics, perioperative morbidity and mortality, and long-term results are reported.

Results: During the study period, 444 patients underwent elective EVAR for AAAs. Among them 128 patients (29%) were > 80 years of age. Mean age was 84 ± 3.4 (range 80–96) years, and 110 patients (86%) were male. The EVAR was technically successful in 127 patients (99%) and there were intraoperative mortalities. Within 30 days of the surgery, nine patients (7%) died. Major and minor adverse events occurred in 26 (20%) and 59 (46%) patients, respectively. Factors associated with increased risk of perioperative morbidity and mortality included chronic kidney disease, peripheral artery disease, and the existence of three or more co-morbidities.

Conclusions: EVAR in the elderly can be performed with a high rate of success; however, it is associated with a substantial rate of morbidity and mortality, particularly when patients present with multiple co-morbidities. When performing EVAR in this population group, the risk of rupture must be considered opposed to the life expectancy of these patients and the risk of perioperative morbidity and mortality.

December 2019
Oholi Tovia-Brodie MD, Sevan Letourneau-Shesaf MD, Aviram Hochstadt MD, Arie Steinvil MD, Raphael Rosso MD, Ariel Finkelstein MD and Yoav Michowitz MD

Background: Patients with right bundle branch block (RBBB) prior to transcatheter aortic valve implantation (TAVI) are at high risk for immediate post-procedural heart block and long-term mortality when discharged without a pacemaker.

Objectives: To test whether prophylactic permanent pacemaker implantation (PPI) is beneficial.

Methods: Of 795 consecutive patients who underwent TAVI, 90 patients had baseline RBBB. We compared characteristics and outcomes of the prophylactic PPI with post-TAVI PPI. Need for pacing was defined as  greater than 1% ventricular pacing.

Results: Forty patients with RBBB received a prophylactic PPI (group 1), and in 50 the decision was based on standard post-procedural indications (group 2). There were no significant differences in clinical baseline characteristics. One patient developed a tamponade after a PPI post-TAVI. A trend toward shorter hospitalization duration in group 1 patients was observed (P = 0.06). On long-term follow-up of 848 ± 56 days, no differences were found in overall survival (P = 0.77), the composite event-free survival of both mortality and hospitalizations (P = 0.66), or mortality and syncope (P = 0.65). On multivariate analysis, independent predictors of the need for pacing included baseline PR interval increase of 10ms (odds ratio [OR] 1.21 per 10 ms increment 95% confidence interval [95%CI] 1.02–1.44, P = 0.028), and the use of new generation valves (OR 3.92, 95%CI 1.23–12.46, P = 0.023).

Conclusions: In patients with baseline pre-TAVI RBBB, no outcome differences were found with prophylactic PPI. On multivariate analysis, predictors of the need for pacing included baseline long PR interval, and the use of newer generation valves.

September 2019
Arthur Shiyovich MD and Ran Kornowski MD FESC FACC

Aortic stenosis (AS) is a common valvular pathology and is increasing in prevalence. Severe symptomatic AS is associated with serious outcomes if left untreated. Transcatheter aortic valve implantation (TAVI) is an innovative modality, which has revolutionized the treatment of AS. With growing experience and technological upgrades, TAVI has become a valid alternative to surgical valve replacement. However, TAVI is associates with increase non-negligible risks of mortality, stroke, physical disability, and healthcare expenditures. Furthermore, imaging modalities have shown new ischemic lesions in most patients following TAVI (silent strokes), which might be related to worse subsequent neurocognitive function. Embolic protective devices are emerging as a safe, technically feasible implements to reduce the burden of periprocedural thromboembolism, and have shown promising results of improved clinical outcomes.

May 2019
Hussein Sliman MD, Avinoam Shiran MD, Dallit Mannheim MD, Eyal Avraham MD, Ron Karmeli MD, Nader Khader MD, Barak Zafrir MD, Ronen Rubinshtein MD and Ronen Jaffe MD

Background: Access-site bleeding is a common complication of transfemoral transcatheter aortic valve implantation (TAVI). Percutaneous stent-graft implantation within the femoral artery may achieve hemostasis and avert the need for more invasive surgical vascular repair; however, failure to advance a guidewire antegradely via the injured vessel may preclude stent delivery. While retrograde stent-graft delivery from the distal vasculature may potentially enable percutaneous control of bleeding, this approach has not been reported.

Objectives: To assess the feasibility of a retrograde approach for stent-graft implantation in the treatment of access-site bleeding following transfemoral TAVI.

Methods: A prospective TAVI registry was analyzed. Of 349 patients who underwent TAVI, transfemoral access was used in 332 (95%). Access-site injury requiring stent-graft implantation occurred in 56 (17%). In four patients (7%), antegrade wiring across the site of vascular injury was not possible and a retrograde approach for stent delivery was used.

Results: Distal vascular access was achieved via the superficial femoral or profunda artery. Retrograde advancement of a polymer-coated 0.035” wire to the abdominal aorta, followed by stent-graft delivery to the common femoral artery, achieved hemostasis in all cases. During a median (interquartile range) follow-up period of 198 (618) days (range 46–2455) there were no deaths and no patient required additional vascular interventions.

Conclusions: A retrograde approach for stent-graft delivery is feasible and allows percutaneous treatment of a common femoral artery injury following TAVI in patients who are not suitable for the conventional antegrade approach.

July 2018
Eilon Ram MD, Leonid Sternik MD, Alexander Lipey MD, Sagit Ben Zekry MD, Ronny Ben-Avi MD, Yaron Moshkovitz MD and Ehud Raanani MD

Background: Unicuspid and bicuspid aortic valve (BAV) are congenital cardiac anomalies associated with valvular dysfunction and aortopathies occurring at a young age.

Objectives: To evaluate our experience with aortic valve repair (AVr) in patients with bicuspid or unicuspid aortic valves.

Methods: Eighty patients with BAV or unicuspid aortic valve (UAV) underwent AVr. Mean patient age was 42 ± 14 years and 94% were male. Surgical technique included: aortic root replacement with or without cusp repair in 43 patients (53%), replacement of the ascending aorta at the height of the sino-tubular junction with or without cusp repair in 15 patients (19%), and isolated cusp repair in 22 patients (28%).

Results: The anatomical structure of the aortic valve was bicuspid in 68 (85%) and unicuspid in 12 patients (15%). Survival rate was 100% at 5 years of follow-up. Eleven patients (13.7%) underwent reoperation, 8 of whom presented with recurrent symptomatic aortic insufficiency (AI). Late echocardiography in the remaining 69 patients revealed mild AI in 63 patients, moderate recurrent AI in 4, and severe recurrent AI in 2. Relief from recurrent severe AI or reoperations was significantly lower in patients who underwent cusp repair compared with those who did not (P = 0.05). Furthermore, the use of pericardial patch augmentation for the repair was a predictor for recurrence (P = 0.05).

Conclusions: AVr in patients with BAV or UAV is a safe procedure with low morbidity and mortality rates. The use of a pericardial patch augmentation was associated with higher repair failure.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel