• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Original Articles

IMAJ | volume 16

Journal 1, January 2014
pages: 5-10

Endovascular Repair of Complex Aortic Aneurysms

    Summary

    Background: Surgery for complex aortic aneurysms (thoracoabdominal, juxtarenal and pseudoaneurysms) is associated with a high morbidity and mortality rate. Branched and fenestrated stent grafts constitute a new technology intended as an alternative treatment for this disease.

    Objectives: To describe a single-center experience with fenestrated and branched endografts for the treatment of complex aortic aneurysms.

    Methods: We reviewed all cases of complex aortic aneurysms treated with branched or fenestrated devices in our center. Data collected included device specifics, perioperative morbidity and mortality, re-intervention rates and mid-term results.

    Results: Between 2007 and 2012 nine patients were treated with branched and fenestrated stent grafts. Mean age was 73 years. Mean aneurysm size was 63 mm. Perioperative mortality was 22% (2/9). During the follow-up, re-interventions were required in 3 patients (33%). Of 34 visceral artery branches 33 remained patent, resulting in a patency rate of 97%. Sac expansion was seen in a single patient due to a large endoleak. No late aneurysm- related deaths occurred.

    Conclusions: Branched and fenestrated stent grafts are feasible and relatively safe alternatives for the treatment of complex aortic aneurysms involving the visceral segment. Further research is needed to determine the long-term durability of this new technology. 

    Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
    The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
    © All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

    2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel