• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Original Articles

IMAJ | volume 12

Journal 3, March 2010
pages: 144-149

Benefits of High Frequency Oscillatory Ventilation for Premature Infants

    Summary

    Background: High frequency oscillatory ventilation based on optimal lung volume strategy is one of the accepted modes of ventilatory support for respiratory distress syndrome in very low birth weight infants. In 1999 it was introduced in our unit as the primary ventilation modality for RDS[1].

    Objectives: To evaluate if the shift to HFOV[2] influenced the outcome of ventilated VLBW[3] infants in the neonatal intensive care unit of Carmel Medical Center.

    Methods: Data were obtained from the medical charts of VLBW infants born at Carmel Medical Center, and late mortality data were taken from the Israel Ministry of Internal Affairs records. A retrospective analysis and a comparison with a historical control group ventilated by the conventional method were performed.

    Results: A total of 232 VLBW infants with RDS were mechanically ventilated, from 1995 to 2003: 120 were ventilated using HFOV during the period 1999–2003 and 102 infants using CV[4] during 1995–1999. The mean gestational age of survivors was 27.4 ± 2 weeks in the HFOV group and 28.4 ± 2 in the conventional ventilation group (P = 0.03). The sub-sample of infants with birth weights <1000 g ventilated with HFOV showed higher survival rates than the infants in the conventional ventilation group, 53 vs. 25 (64.6% vs. 44.6%) respectively (P < 0.05). A trend for lower incidence of pulmonary interstitial emphysema was observed in the HFOV group.

    Conclusions: The introduction of HFOV based on optimal lung volume strategy proved to be an efficient and safe method of ventilation support for VLBW infants in our unit.



    [1] RDS = respiratory distress syndrome
    [2] HFOV = high frequency oscillatory ventilation
    [3] VLBW = very low birth weight
    [4] CV = conventional ventilation

    Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
    The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
    © All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

    2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel