Arie Y. Nemet MD, Leena Asalee MD, Yaron Lang MD, Daniel Briscoe MD and Ehud I. Assia MD
Background: One of the most alarming ocular injury trends in recent years has been the proliferation of paintball guns and the proportional increase in the number of ocular eye injuries caused by paintballs.
Objectives: To describe five cases of paintball eye injuries that resulted in loss of functional vision in four of them.
Methods: We conducted a retrospective interventional case series of the clinical course of five patients with paintball eye injuries treated in the ophthalmology departments of two medical centers.
Results: Five young males were evaluated for paintball injuries caused by blunt trauma. There was one case of full-thickness laceration (globe rupture). Four patients required one to five surgical interventions: three of these involved the removal of traumatic cataract including two eyes with significant zonular dehiscence treated by lens capsule conservation using anchoring devices, one retinal surgery and two glaucoma filtration surgeries. However, final visual outcome was not favorable due to irreversible retinal damage.
Conclusions: Paintball trauma often results in significant ocular injury and loss of functional vision despite successful surgical interventions. Most injuries are easily preventable and occur in under-supervised settings. Improved safety measures, strict regulation enforcement and appropriate public education could prevent such serious damage.
Etty Daniel-Spiegel MD, Micha Mandel PhD, Daniel Nevo MA, Avraham Ben-Chetrit MD, Ori Shen MD, Eliezer Shalev MD and Simcha Yagel MD
Background: Selection of appropriate reference charts for fetal biometry is mandatory to ensure an accurate diagnosis. Most hospitals and clinics in Israel use growth curves from the United States. Charts developed in different populations do not perform well in the Israeli population.
Objectives: To construct new reference charts for fetal biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), using a large sample of fetuses examined at 14–42 weeks gestational age in a medical center and a community ultrasound unit located in two different regions of Israel.
Methods: Data from the medical center and the community clinic were pooled. The mean and standard error of each measure for each week was calculated. Based on these, reference charts were calculated using quantiles of the normal distribution. The performance of the reference charts was assessed by comparing the new values to empirical quantiles.
Results: Biometric measurements were obtained for 79,328 fetuses. Growth charts were established based on these measurements. The overall performance of the curves was very good, with only a few exceptions among the higher quantiles in the third trimester in the medical center subsample.
Conclusions: We present new local reference charts for fetal biometry, derived from a large and minimally selected Israeli population. We suggest using these new charts in routine daily obstetric practice.