September 2013
S. Schwartzenberg, V. Meledin, L. Zilberman, S. Goland, J. George and S. Shimoni

Background: The pathophysiology of aortic stenosis (AS) involves inflammatory features including infiltration of the aortic valve (AV) by activated macrophages and T cells, deposition of lipids, and heterotopic calcification.

Objectives: To evaluate the correlation between white blood cell (WBC) differential count and the occurrence and progression of AS.

Methods: We identified in our institutional registry 150 patients with AS who underwent two repeated echo studies at least 6 months apart. We evaluated the association between the average of repeated WBC differential counts sampled during the previous 3 years and subsequent echocardiographic AS indices.

Results: There was no significant difference in total WBC, lymphocyte or eosinophil count among mild, moderate or severe AS groups. There was a progressive decrease in monocyte count with increasing AS severity (P = 0.046), more prominent when comparing the mild and severe groups. There was a negative correlation between AV peak velocity or peak or mean gradient and monocyte count in the entire group (r = -0.31, -0.24, and -0.25 respectively, all P ≤ 0.01). Similar partial correlations controlling for age, gender, hypertension, smoking, dyslipidemia and ejection fraction remained significant. The median changes over time in peak velocity and peak gradients in AS patients were 0.44 (0–1.3) m/sec/year and 12 (0–39) mmHg/year, respectively. There was no correlation between any of the WBC differential counts and the change in peak velocity or peak gradient per year.

Conclusions: Severe AS is associated with decreased total monocyte count. These findings may provide further clues to the mechanism underlying the pathogenesis of aortic stenosis.

August 2013
A. Segev, D. Spiegelstein, P. Fefer, A. Shinfeld, I. Hay, E. Raanani and V. Guetta

Background: Trans-catheter aortic valve implantation (TAVI) has emerged as a novel therapeutic approach for patients with severe tricuspid aortic stenosis (AS) not suitable for aortic valve replacement.

Objectives: To describe our initial single-center experience with TAVI in patients with "off-label" indications.

Methods: Between August 2008 and December 2011 we performed TAVI in 186 patients using trans-femoral, trans-axillary, trans-apical and trans-aortic approaches. In 11 patients (5.9%) TAVI was undertaken due to: a) pure severe aortic regurgitation (AR) (n=2), b) prosthetic aortic valve (AV) failure (n=5), c) bicuspid AV stenosis (n=2), and d) prosthetic valve severe mitral regurgitation (MR) (n=2).

Results: Implantation was successful in all: six patients received a CoreValve and five patients an Edwards-Sapien valve. In-hospital mortality was 0%. Valve hemodynamics and function were excellent in all patients except for one who received an Edwards-Sapien that was inside a Mitroflow prosthetic AV and led to consistently high trans-aortic gradients. No significant residual regurgitation in AR and MR cases was observed.
Conclusions: TAVI is a good alternative to surgical AV replacement in high risk or inoperable patients with severe AS. TAVI for non-classical indications such as pure AR, bicuspid AV, and failed prosthetic aortic and mitral valves is feasible and safe and may be considered in selected patients. 

E. Nachum, A. Shinfeld, A. Kogan, S. Preisman, S. Levin and E. Raanani
 Background: Patients with Marfan syndrome are referred for cardiac surgery due to root aneurysm with or without aortic valve regurgitation. Because these patients are young and frequently present with normal-appearing aortic cusps, valve sparing is often recommended. However, due to the genetic nature of the disease, the durability of such surgery remains uncertain.

Methods:  Between February 2004 and June 2012, 100 patients in our department suffering from aortic aneurysm with aortic valve regurgitation underwent elective aortic valve-sparing surgery. Of them, 30 had Marfan syndrome, were significantly younger (30 ± 13 vs. 53 ± 16 years), and had a higher percentage of root aneurysm, compared with ascending aorta aneurysm in their non-Marfan counterparts. We evaluated the safety, durability, clinical and echocardiographic mid-term results of these patients.

Results: While no early deaths were reported in either group, there were a few major early complications in both groups. At follow-up (ranging up to 8 years with a mean of 34 ± 26 months) there were no late deaths, and few major late complications in the Marfan group. Altogether, 96% and 78% of the patients were in New York Heart Association functional class I-II in the Marfan and non-Marfan groups respectively. None of the Marfan patients needed reoperation on the aortic valve. Freedom from recurrent aortic valve regurgitation > 3+ was 94% in the Marfan patients.

Conclusions: Aortic valve-sparing surgery in Marfan symdrome patients is safe and yields good mid-term clinical outcomes.

July 2013
N. Roguin Maor
 Background: Smoking is a serious health issue worldwide. Smoking trends among physicians predict similar trends in the general population. Little is known about current smoking rates among physicians.

Objectives: To investigate current smoking trends among Israeli physicians.

Methods: All practicing physicians at a tertiary university-affiliated medical center in central Israel were invited to complete a Web-based questionnaire on smoking habits and smoking-related issues via the institutional email. Findings were compared to those in the general population and between subgroups.

Results: Of the 90 responders (53 male, 88 Jewish), 54 (60%) had never smoked, 21 (23.3%) were past smokers, and 15 (16.7%) were current smokers. The rate of current smokers was lower than in the general population. The proportion of current smokers was higher among residents than attending physicians and among physicians in surgical compared to medical specialties. Past smokers accounted for 17.9% of the residents (average age at quitting 26.2 years) and 28.1% of the attending physicians (average age at quitting 33.0 years). Non-smokers more frequently supported harsh anti-smoking legislation.

Conclusions: The rate of smoking is lower in physicians than in the general population but has not changed over the last 15 years. Anti-smoking programs should particularly target physicians in surgical specialties. 

August 2010
H. Danenberg, A. Finkelstein, R. Kornowski, A. Segev, D. Dvir, D. Gilon, G. Keren, A. Sagie, M. Feinberg, E. Schwammenthal, S. Banai, C. Lotan and V. Guetta

Background: The prevalence of aortic stenosis increases with advancing age. Once symptoms occur the prognosis in patients with severe aortic stenosis is poor. The current and recommended treatment of choice for these patients is surgical aortic valve replacement. However, many patients, mainly the very elderly and those with major comorbidities, are considered to be at high surgical risk and are therefore denied treatment. Recently, a transcatheter alternative to surgical AVR[1] has emerged.

Objectives: To describe the first year experience and 30 day outcome of transcatheter aortic self-expandable CoreValve implantation in Israel.

Methods: Transcatheter aortic valve implantation using the CoreValve system has been performed in Israel since September 2008. In the following year 55 patients underwent CoreValve TAVI[2] in four Israeli centers.

Results: Patients' mean age was 81.7 ± 7.1 years; there were 35 females and 20 males. The mean valve area by echocardiogram was 0.63 ± 0.16 cm2. The calculated mean logistic Euroscore was 19.3 ± 8%. Following TAVI, mean transvalvular gradient decreased from baseline levels of 51 ± 13 to 9 ± 3 mmHg. The rate of procedural success was 98%. One patient died on the first day post-procedure (1.8%) and all-cause 30 day mortality was 5.5% (3 of 55 patients). One patient had a significant post-procedural aortic regurgitation of > grade 2. Symptomatic improvement was evident in most patients, with reduction in functional capacity grade from 3.2 ± 0.6 at baseline to 1.4 ± 0.7. The most common post-procedural complication was complete heart block, which necessitated permanent pacemaker implantation in 37% of patients.

Conclusions: The Israeli first year experience of transcatheter aortic valve implantation using the CoreValve self-expandable system demonstrates an effective and safe procedure for the treatment of severe aortic stenosis in patients at high surgical risk.






[1] AVR = aortic valve replacement



[2] TAVI = transcatheter aortic valve implantation


April 2009
D. Dvir, A. Assali, H. Vaknin, A. Sagie, Y. Shjapira, A. Battler, E. Porat and R. Kornowski

The incidence of aortic valve stenosis is growing rapidly in the elderly. Nonetheless, many symptomatic patients are not referred for surgery usually because of high surgical risk. Unfortunately, percutaneous balloon valvuloplasty is unsatisfactory due to high recurrence rates. In 2002, Cribier and colleagues were the first to describe percutaneous aortic valve implantation, opening a new era of aortic stenosis management. In the present review we report a patient treated by this novel method, discuss and assess how it is implanated, report the findings of studies conducted to date, and suggest future directions for percutaneous treatment of aortic valve disease.
 

July 2003
A. Shinfeld, E. Kachel, Y. Paz, S. Praisman and A.K. Smolinsky

Background:  After the introduction of endoscopic techniques to other surgical fields, like general surgery, gynecology and thoracic surgery, cardiac surgeons sought their own methods of using minimally invasive techniques.

Objectives:  To examine whether this approach is less invasive and yields better results, more desirable cosmetic results, and a more rapid and complete rehabilitation, maintaining safety, efficacy, and outcome equivalent to those of more established procedures, such as median sternotomy.

Methods:  From January 2000 to July 2001, 22 patients underwent video-assisted port-access mitral or aortic valve repair or replacement with the Heartport system in our department, and one underwent closure of atrial septal defect.

Results:  Intraoperative transesophageal echocardiography revealed excellent functional results. Total operating room time, perfusion time, and cross-clamp time in this technique decreased with our growing experience, and remains stable. There were no intraoperative reversals to mid-steronomy, no mortalities, and only one complication 24 hours after surgery.

Conclusions:  Thoracoscopic assisted cardiac surgery (via port access) provides all the advantages of minimally invasive surgery, accelerates recovery, decreases pain, and maintains overall surgical efficacy, while avoiding the complications and pathology of mid-sternotomy.  For appropriate patients, this is the method of choice in our department.

January 2003
S. Goland, G. Loutaty, A. Arditi, E. Snir, I. Abend and A. Caspi

Background: Concomitant mitral valve regurgitation is often present in patients with aortic stenosis. The additional MV[1] replacement is associated with high operative risk. Previous studies have shown an amelioration of MV regurgitation after aortic valve replacement but most of the patient groups were heterogenous.

Objectives: To determine whether AV[2] replacement for aortic stenosis has any effect on MV regurgitation.

Methods: We reviewed two-dimensional echocardiography and color flow Doppler assessment of both aortic stenosis and MV regurgitation severity in 30 patients. Patients with previous MV surgery, organic MV disease, occlusive carotid artery disease, ejection fraction < 50%, and coexisting significant AV regurgitation were excluded. Preoperatively, MV regurgitation was mild in 23 patients (77%) and moderate in 7 (23%); in no patient was the condition severe. All patients had severe atrial stenosis (peak average aortic gradient was 86  ± 22 mmHg in the mild MV regurgitation group, and 83 ± 26 mmHg in the moderate group). The patients were divided into two groups according to the severity of MV regurgitation (associated mild, and moderate). Group 2, with moderate MV regurgitation, was the most problematic in terms of decision making for concomitant MV surgery. Therefore, additional assessment of several parameters was required.

Results: There was a significant decrease in MV regurgitation area (7.6 ± 1.9 vs. 3.0 ± 1.2 cm2, P £ 0.012) and percent (28 ± 5% vs. 12 ± 6%, P £ 0.001) between pre- and postoperative evaluation. Thus, the severity of the condition in all patients with moderate MV regurgitation decreased after AV replacement; in the mild group it remained unchanged in 53% or improved in 47%. There was no association between the preoperative gradient on the aortic valve and the degree of MV regurgitation.

Conclusions: In our population of patients with severe atrial stenosis there were no patients with coexisting severe MV regurgitation. The decision to repair or replace a severely leaking mitral valve is an easy one, as in mild MV regurgitation. The clinical problem often presents in patients with severe aortic stenosis and moderate MV regurgitation. We believe that additional MV surgery is not necessary, at least in patients with preserved left ventricular function and without organic MV disease.






[1] MV = mitral valve



[2] AV = aortic valve