Danny Alon MD, Gideon Y. Stein MD PhD, Vered Hadas-Golan RN, Luba Tau MD, Tal Brosh MD and Dan Turner MD
Background: Guidelines recommend hepatitis B virus (HBV) vaccination of all adults positive for human immunodeficiency virus (HIV). Immune responses to single-antigen HBV vaccine among HIV-positive patients are low when compared with HIV-negative adults. Sci-B-Vac™ is a recombinant third-generation HBV that may be advantageous in this population.
Objectives: To examine the immune responses to Sci-B-Vac among HIV-positive adults.
Methods: We conducted a prospective cohort study involving HIV-positive adults who had negative HBV serology (HBSAg, HBSAb, HBcoreAb). Sci-B-Vac at 10 µg/dose was administered intramuscularly upon recruitment and after 1 and 6 months. HBSAb levels were checked 1 month after each dose; a level > 10 mlU/ml was considered protective. Data regarding age, gender, CD4 level, and viral load were collected.
Results: The study group comprised 31 patients. Average CD4 count was 503 ± 281 cells/ml, and average viral load was 44 copies/ml. Median interquartile range (IQR) HBVAb titers after the first, second and third immunizations were 0 (0, 3.5), 30 (6, 126) and 253 (81, 408) mlU/ml. Significant titer elevations were found between the second and third immunizations (P = 0.0003). The rate of patients considered protected was 16% after the first, 65% after the second (P < 0.0001), and 84% after the third dose (P = 0.045). No adverse events were reported. More patients under the age of 40 years responded to the first immunization (28% vs. 0%, P = 0.038). CD4 level had no influence on immunization rates.
Conclusions: Sci-B-Vac might achieve better immunization rates among HIV-positive adults compared to the single-antigen vaccine and thus deserves further evaluation in a randomized, double-blind study in this population.
Dan Carter MD and Rami Eliakim MD
Background: Bowel ultrasound has several possible uses in inflammatory bowel disease (IBD), including the initial evaluation of suspected IBD, monitoring of therapeutic response, detection of relapse, and diagnosis of complications as well as of extra-intestinal manifestations. However, its use has been limited mainly to countries where it is performed by the attending physician.
Objectives: To investigate the feasibility and sensitivity of bedside bowel ultrasound performed by a gastroenterologist for assessing disease activity and complications in IBD.
Methods: We performed a feasibility study to compare the results of bowel ultrasound examination with those of another cross-sectional imaging modality (computed tomographic enterography or magnetic resonance enterography) in Crohn's disease, or with colonoscopy in ulcerative colitis.
Results: Between May 2015 and March 2016, 178 bowel ultrasound examinations were performed in 178 patients with suspected or established diagnosis of IBD. In 79 cases the results of another cross-sectional imaging or endoscopic examination performed within 3 months prior to the ultrasound exam were available. The sensitivity for detection of intestinal bowel thickening (a surrogate of inflammation) was 90%, and for detection of Crohn's disease complications, namely bowel stenosis and inflammatory mass, was 94% and 75%, respectively.
Conclusions: Bowel ultrasound is a useful and feasible bedside imaging tool for the detection of inflammation and complications in IBD patients. Bedside bowel ultrasound can be a valuable non-invasive tool to assess disease activity and complications in IBD patients when performed by the attending physician.
Uri Landes MD, Arthur Kerner MD, Amit Segev MD, Haim Danenberg MD, Yaron Shapira MD, Ariel Finkelstein MD and Ran Kornowski MD FESC FACC
Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery.
Objectives: To report the multicenter TVIV experience in Israel.
Methods: We approached multiple centers and collected data regarding seven TVIV cases.
Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up.
Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk.
Shira Rosenberg Bezalel MD, Daniel Elbirt MD, Hana Leiba MD and Zev Moshe Sthoeger MD