IMAJ | volume 15
Journal 11, November 2013
pages: 682-687
Summary
Background: Contrast-induced nephropathy (CIN) is one of the major causes of new-onset renal failure in hospitalized patients. Although renin-angiotensin-aldosterone system (RAAS) blocking agents are widely used among patients requiring contrast studies, data on the effect of these agents on the development of CIN are sparse and inconsistent.
Objectives: To evaluate in a randomized control trial whether uninterrupted administration of angiotensin II (AngII) blockade medications influence estimated glomerular filtration rate (eGFR) in patients undergoing non-emergent coronary angiography.
Methods: Patients receiving treatment with angiotensin-converting enzyme inhibitors/angiotensin receptor blockers (ACE-I/ARB) were recruited consecutively. The enrolled subjects were randomized into three groups at a 1:1:1 ratio: group A (ACE/ARB stopped 24 hours prior to the procedure and restarted immediately after the procedure), group B (ACE/ARB stopped 24 hours prior to the procedure and restarted 24 hours after the procedure), and group C (ACE/ARB continued throughout the study period). Plasma creatinine was measured and eGFR was calculated according to the Cockroft-Gault equation before and 48 hours after the coronary angiography. The primary endpoint was a change in eGFR at 48 hours.
Results: Groups A, B and C comprised 30, 31 and 33 patients respectively. The mean age of the study population was 65 ± 12 years and 67% were males. Fifty percent of the subjects had diabetes mellitus. The primary endpoint analysis showed that at 48 hours after the procedure there was no difference in ΔeGFR between groups A and C (4.25 ± 12.19 vs. 4.65 ± 11.76, P = 0.90) and groups B and C (3.72 ± 17.42 vs. 4.65 ± 11.76, P = 0.82). In post-hoc analysis the patients were clustered according to the following groups: medical alternation (group A and B) versus control (group C) and to baseline eGFR ≥ 60 ml/min vs. eGFR < 60 ml/min. In patients with baseline eGFR < 60 ml/min the ΔeGFR (baseline eGFR-eGFR 48 hours post-angiography) was significantly different between the intervention vs. control group (median 5.61 vs. median -2.19, P = 0.03 respectively). While in patients with baseline eGFR ≥ 60 ml/min there was no significant difference in ΔeGFR between the intervention and control groups.
Conclusions: ACE-I and ARB can safely be used before and after coronary angiography in patients with eGFR ≥ 60 ml/min.