• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Gastroenterology

IMAJ | volume

Journal 2, February 2000
pages: 122-125

Comparison of Assays for Anti-endomysial and Anti- transglutaminase Antibodies for Diagnosis of Pediatric Celiac Disease

    Summary

    Background: Anti-endomysial antibodies are sensitive and specific markers for celiac disease. This antibody has recently been identified as an antibody to tissue transglutaminase, an enzyme that cross-links and stabilizes extracellular matrix proteins.

    Objectives: To evaluate the clinical usefulness of an enzyme-linked immunoassay for anti-transglutaminase antibodies, and to compare the results with those of AEA, the current gold standard serological test for celiac disease.

    Methods: Serum samples were collected from 33 patients with biopsy-proven celiac disease and AEA tests were performed. Control samples for anti-transglutaminase were obtained from 155 patients. An ELISA test for immunoglobulin A anti-transglutaminase utilizing guinea pig liver transglutaminase was developed and performed on all sera.  Cutoff values for the test were performed using logistic regression and receiver operating curves analysis.

    Results: An optical density cutoff value of 0.34 was established for the assay. The mean value was 0.18±0.19 optical density for controls, and 1.65±1.14 for patients with celiac disease (P<0.001). Sensitivity and specificity of the assay were both 90%, while AEA had a sensitivity and specificity of 100% and 94%, respectively.

    Conclusions: A tissue transglutaminase-based ELISA test is both sensitive and specific for  detection of celiac disease.

    __________________________________

     

    AEA = anti-endomysial antibody

    Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
    The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
    © All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

    2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel