        אוגוסט 1999

        סנטיאגו ריכטר, רחל חג'אג', משה שלו וישראל ניסנקורן
        עמ'

        Measuring Residual Urine by Portable Ultrasound Scanner

         

        Santiago Richter, Rachel Hag'ag, Moshe Shalev, Israel Nissenkorn

         

        Urology Dept. and Outpatient Clinic, Meir Hospital, Kfar Saba and Sackler Faculty of Medicine, Tel Aviv University

         

        Urethral catheterization, the standard method of measuring residual urine, is uncomfortable and associated with risk of infection and trauma to the urethra. It has also been reported as inaccurate to a certain extent. We compared catheterization with ultrasound scanning in a prospective study of 52 men and 3 women.

        100 measurements of postvoiding residual urine by portable ultrasound scanner, were each followed immediately by urethral catheterization (both procedures performed by an experienced nurse in our outpatient clinic). A difference of >25€ml between measurements by scanner and by catheter was considered significant.

        The range of residual urine measured by scanner was 1-425 ml, and by catheter 1-410 ml. There was good matching between the 2 methods in 85 of 100 measurements (scanning accuracy 85%). In 30/85 matching was excellent while in 55 cases the mean difference was 8.5±6.2 ml, range 1-24 ml. The accuracy of scanning was 85%; there was perfect matching between the 2 methods in 30 cases. In the remaining 15 cases the mean difference was 41.8±13.6 (range 25-56).

         

        Each catheterization took 4-5 minutes and scanning 30 seconds. There were no complications after catheterization, but all reported discomfort and dysuria for 1-2 hours thereafter. Scanning was absolutely uneventful in all.

        The cost per catheterization, including medication, disposable materials and personnel time was approximately 80 NIS. Our 80-90 measurements of residual urine a month require annually about 80 hours and a budget of about NIS 80,000. Scanning requires only 8 hours, while the cost of the portable scanner is significantly less than NIS 80,000 and it can be used for more than a year.

        We conclude that measuring urine residual with the noninvasive scanner instead of by catheterization is easier, more accurate, and more cost-effective.

        מאי 1999

        הראל גילוץ, אהרון גבריאל ושמואל יורפסט
        עמ'

        Accidental Severance of a Venous Catheter: Diagnostic and Therapeutic Approach

         

        Harel Gilutz, Aharon Gavriel, Shmuel Yurfest

         

        Cardiology, Heart and Lung, and Vascular Surgery Depts., Soroka Medical Center and Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer Sheba

         

        The most common invasive procedure performed in hospitals ithe insertion of a vascular access device. This procedure has the rare complication ofcatheter emboli. Accidental cutting of a peripheral catheter, the use of duplex ultrasound to locate the cut and the extraction of the catheter through a venesection is described. If peripheral extraction fails, percutaneous extraction or thoracotomy should be tried, in that order. The immediate precautions have an impact on the final results.

        בנימין זאבי, גלית בר-מור ומיכאל ברנט
        עמ'

        1000 Cardiac Catheterizations in Congenital Heart Disease

         

        Benjamin Zeevi, Galit Bar-Mor, Michael Berant

         

        Cardiac Catheterization Unit, Schneider Children's Medical Center, and Sackler School of Medicine, Tel Aviv University

         

        Over the past 15 years, percutaneous therapeutic cardiac catheterization has become increasingly important in the treatment of congenital heart disease. We describe our experience in 1000 such catheterizations between 1993-1997. 55% were in 1-12-year-olds; only 20% were in patients younger than 1 year old and 11.3% were in adults with congenital heart defects. In about 50% it was at least a second cardiac catheterization. Overall, there were 425 therapeutic cardiac catheterizations, increasing from 33% in the first 200 procedures, to 63% in the last 200.

        We performed 30 different types of therapeutic catheterizations: 23.3% were valvular dilations, 21.4% vessel angioplasties, 36.9% closure procedures, 9.2% electrophysiological procedures, and 9.2% miscellaneous. In 31.3% of therapeutic catheterizations we used 12 new procedures. Minor complications occurred in 8.5% and major in 0.6%; most complications were successfully treated or were self-limited and there was no residual damage.

        In this report the current role of each type of major catheterization is discussed on the basis of our experience. Further development of technology for lesions not amenable to currently available transcatheter methods, and longer follow-up for current techniques will consolidate the role of therapeutic cardiac catheterization in congenital heart disease.

        מרץ 1999

        בנימין זאבי, גלית בר-מור ומיכאל ברנט
        עמ'

        Balloon Angioplasty of Native Coarctation of the Aorta

         

        Benjamin Zeevi, Galit Bar-Mor, Michael Berant

         

        Cardiac Catheterization Unit, Schneider Children's Medical Center, Petah Tikva, and Sackler School of Medicine, Tel Aviv University

         

        The use of balloon dilatation to treat native coarctation of the aorta is gaining acceptance among interventional pediatric cardiologists, but is still controversial. We describe our experience with this procedure in 21 children, mean age 5.6 years and mean weight 21.1 kg. Most had an additional congenital heart defect, most commonly a bicuspid aortic valve. 17 were asymptomatic, 3 had tachypnea and 1 infant had severe congestive heart failure and was ventilated. The mean systolic blood pressure was 129.7 mm Hg.

         

        Balloon dilatation was successful in 90% (19), decreasing the mean maximal systolic gradient from 35.3 to 9 mm Hg (p<0.001), and increasing the narrowest area from 3.9 to 8.2 mm (p<0.001), with a mean balloon-to-coarctation width-ratio of 2.8. There were no complications. Of 15 who underwent repeat cardiac catheterization at a mean interval of 10.6 months, 2 had a maximal systolic gradient of more than 20 mm Hg. 1 of these underwent successful repeat angioplasty and the other, who also had a small aneurysm, underwent surgical repair successfully. 2 others had small aneurysms and they are being followed clinically.

         

        All patients were seen again after a mean interval of 31 months. The mean systolic blood pressure was 104 mm Hg, significantly lower than before intervention (p<0.002). 1 had an increased pressure gradient between right arm and leg of 35 mm Hg at later follow-up, and repeat cardiac catheterization demonstrated a good result 13 months after the initial procedure. She is awaiting a third catheterization. Overall, 90% had good mid-term results.

         

        Based on our experience and recent reports, balloon angioplasty is safe and effective in most children older than 7 months and should be considered a viable alternative to operation for discrete aortic coarctation. Further long-term evaluation is needed.

        דצמבר 1998

        יהונתן פינטהוס, יורם מור ויעקב רמון
        עמ'

        The Mitrofanoff Pouch in Lower Urinary Tract Reconstruction

         

        J.H. Pinthus, Y. Mor, J. Ramon

         

        Urology Dept., Chaim Sheba Medical Center, Tel Hashomer

         

        The Mitrofanoff principle, first described in 1980, consists of implanting a tubular organ such as the appendix, ureter, or fallopian tube into the wall of the bladder (or urinary reservoir) to create a non-refluxing, catherizable urinary conduit. Between 1993-1996, 7 men and 1 woman (aged 48-64, average 59) underwent radical cystectomy and urethrectomy combined with the creation of a MAINZ I urinary reservoir (based on the Mitrofanoff principle). In men the indication for the procedure was the diagnosis of invasive transitional cell carcinoma of the bladder with involvement of the prostatic urethra. All patients had refused urinary diversion to an ileal conduit because of its deleterious effect on the quality of life.

         

        In all patients the postoperative course was uneventful, apart from intraperitoneal urinary leakage from the reservoir in 1, successfully managed conservatively. The patients have gained full control of urinary drainage, performing intermittent self-catheterizations every 4-5 hours. In 3 patients there were difficulties with catheterization due to stenosis of the conduit, usually at the skin level. None have suffered leakage from the reservoir, during the day, even when it was full.

        Our experience shows that creation of a continent urinary reservoir according to the MAINZ I technique is an excellent surgical solution for patients in whom the creation of an orthotopic reservoir is impractical. The use of the umbilicus as a stomal site preserves normal body image and thus does not interfere with quality of life as in those undergoing radical cystectomy.

        אוקטובר 1998

        שחר צימנד, עינת בירק, מירה פרנד, פטרישה בנימין ויוליוס הגש
        עמ'

        Transcatheter Closure of Atrial Septal Defects: Initial Clinical Applications

         

        Shahar Zimand, Einat Birk, Mira Frand, Patricia Benjamin, Julius Hegesh

         

        Dept. of Pediatric Cardiology, Sheba Medical Center, Tel Hashomer and Schneider Medical Center, Petah Tikva

         

        The incidence of congenital heart defects is 0.8% of live-born infants. Of these 13% are ostium secundum atrial septal defects (ASD) which can be successfully repaired by open heart surgery with less than 1% mortality. However, morbidity associated with cardiac surgery is universal. Transcatheter closure of ASDs was introduced 2 decades ago to decrease surgical complications, hospital stay and cost. Few devices have undergone clinical trials but all of them have been associated with instances of failure and complications. The most important mechanism for acute failure was selection of cases with too large a defect or selection of a defective device. In the past decade great progress has been made with the aid of transesophageal echocardiography (TEE) and modifications of the device. We present our experience in our first 5 patients. They ranged in age from 4 to 27 years; the ASD diameter was 11-15 mm and the device diameter was 17-33 mm. All transcatheter closures were performed on the same day without any complications, and all patients were discharged home after 2 days of hospitalization. We conclude that transcatheter occlusion of ASDs up to 15 mm is feasible, relatively safe and effective. This transcatheter method appears to be a viable alternative to surgery for some patients with secundum atrial septal defects.

        בנימין זאבי, מיכאל ברנט, רמי פוגלמן, גלית בר-מור ולאונרד בלידן
        עמ'

        Transcatheter Closure of Atrial Septal Defect

         

        Benjamin Zeevi, Michael Berant, Rami Fogelman, Galit Bar-Mor, Leonard Blieden

         

        Cardiology Institute, Schneider Children's Medical Center, Petah Tikva and Sackler School of Medicine, Tel Aviv University

         

        Isolated secundum atrial septal defect is one of the most common congenital heart defects. Surgical closure is the treatment of choice but is associated with a chest scar, some morbidity and a relatively long recovery and the use of cardiopulmonary bypass. Transcatheter closure of secundum atrial septal defect is therefor an attractive approach.

        3 children, aged 5-10 years, underwent successful transcatheter closure of moderate to large central atrial septal defects with the Cardioseal device. The procedures were performed under x-ray and transesophageal echocardiographic guidance.

        Our initial experience, and that of others, indicates that transcatheter occlusion of secundum atrial septal defects is safe and effective and can be an appropriate alternative in approximately 60% of patients.

        מאי 1998

        אלברטו הנדלר ואורן אגרנט
        עמ'

        Emergency Stenting for Acute Left Main Coronary Artery Closure during Cardiac Catheterization

         

        Alberto Hendler, Oren Agranat

         

        Catheterization Laboratory, Rama Marpeh Hospital, Petah Tikva

         

        We report a case of acute closure of the left main coronary artery, a rare complication of diagnostic cardiac catheterization, treated by emergency stenting prior to aorto-coronary by-pass surgery. We suggest encroachment of the Judkins catheter into a calcified left main ostium, with dissection and acute thrombosis of this segment, as the possible mechanism.

        Clinically, the patient's condition deteriorated to cardiogenic shock and loss of consciousness. Remarkably, there was no angiographic evidence of significant left main coronary artery disease, besides the presence of calcification in the proximal part of the left coronary system and ventricularization of coronary pressure at the time of engagement. We chose to slide quickly the angioplasty guidewire through the left main coronary artery, which allowed prompt mechanical recanalization and rapid restoration of coronary flow, with dramatic clinical and hemodynamic improvement. This relatively simple procedure allowed stenting the left main artery after brief predilation, and the patient came to by-pass surgery in excellent condition. The rationale for surgery in this case was the need for complete coronary revascularization because of significant 3-vessel coronary artery disease.

        ינואר 1998

        צבי שטיינר, יפים קנדליס, ג'ורג' מוגילנר, דינה אטיאס ויצחק סרוגו
        עמ'

        Conservative Approach in Children with Central Line Infection 


        Zvi Steiner, Yafim Kandelis, George Mogilner, Dina Atias, Isaac Srugo

         

        Dept. of Pediatric Surgery, and Hematology and Clinical Microbiology Units, Bnei-Zion Medical Center, and Bruce Rappaport Faculty of Medicine, The Technion, Haifa

         

        In 1994-1995, central venous lines were placed in 47 children. All except 1 were of the Broviac type, with subcutaneous tunneling via the internal or external jugular vein. Ages were between 7 days and 16 years. Indications for central venous cannulation were chemotherapy (35 cases), TPN (5), prolonged parenteral antibiotics (4), and repeated blood transfusions (3). The catheter was the source of infection in 13 children (28%), 11 of whom were immunocompromised. The commonly identified bacteria were Staphylococcus aureus (4 cases), Pseudomonas aeruginosa (4), coagulase-negative Staphylococcus (2), and various gram-negative rods (3). All cases were treated with antibiotics through the catheter. The most commonly used were oxacillin (4), ceftazidime (4), and amikacin (4). In 10, treatment succeeded without having to remove the line. In 2 others, tunnel infection developed and the catheter had to be removed. 1 child forcefully removed his catheter before treatment could be started. There were no further complications in the group treated conservatively, except for a case of superior vena cava thrombosis in a girl with recurrent infection of the tunnel. In 7 out of 13 treatment was continued and completed at home. This saved 65 days of hospitalization out of 210. We conclude that the conservative approach to treatment is feasible in most cases of infection when the source is the central venous catheter itself. However, when the tunnel is infected, conservative treatment may be ineffective. Treatment can be carried out in the home, with economy in cost and in use of hospital beds, and is preferred by patients and their parents.

        אפריל 1997

        אלי קונן, אלכס גרניאק, בנימינה מורג, יזהר הרדן וזלמן רובינשטיין ז"ל
        עמ'

        Insertion of Hickman Catheters in an Interventional Radiology Suite

         

        Eli Konen, Alex Garniak, Binyamina Morag, Izhar Hardan, Zalman Rubinstein

         

        Depts. of Radiology and Hemato-oncology, Chaim Sheba Medical Center, Tel Hashomer

         

        In the past 20 years Hickman catheters have gained increasing acceptance for many uses, including bone marrow transplantation, long-term chemotherapy, total parenteral nutrition, dialysis, and administration of antibiotics and fluids. Until the past decade these catheters were inserted in the operating room. We present our experience in the percutaneous placement of 203 Hickman catheters in an interventional radiology suite in 190 consecutive patients within a period of 30 months. Catheter placement was successful in 202 (99.5%). The main complications were infections, necessitating removal of the catheter in 11 cases (5.4%) and unintentional dislodgement of the catheter in 8 (3.9%) - all in women and most on the right side. Pneumothorax and thrombosis in the catheter each occurred once. In another patient the guide wire broke during insertion and had to be percutaneously removed from the pulmonary artery. Late fracture of the catheter occurred in 2 others in whom the intravascular fragment was removed percutaneously. We believe that percutaneous Hickman catheter placement in the radiology suite offers advantages over traditional surgical placement.

        הבהרה משפטית: כל נושא המופיע באתר זה נועד להשכלה בלבד ואין לראות בו ייעוץ רפואי או משפטי. אין הר"י אחראית לתוכן המתפרסם באתר זה ולכל נזק שעלול להיגרם. כל הזכויות על המידע באתר שייכות להסתדרות הרפואית בישראל. מדיניות פרטיות
        כתובתנו: ז'בוטינסקי 35 רמת גן, בניין התאומים 2 קומות 10-11, ת.ד. 3566, מיקוד 5213604. טלפון: 03-6100444, פקס: 03-5753303