• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Wed, 17.07.24

Search results


November 2023
Gassan Moady MD, Moanis Serhan MD, Shaul Atar MD, Alexander Shturman MD

Background: The continuity equation (CE) used for evaluating aortic stenosis (AS) is based on values obtained from transthoracic echocardiography (TTE) with the assumption that the left ventricular outflow tract (LVOT) has a circular shape. Transesophageal echocardiography (TEE) may be used for accurate measurement of the LVOT cross-sectional area (CSA). Previous studies have focused on fusion from TEE for LVOT-CSA measurement and TTE for velocity time integrals (VTI) calculations.

Objectives: To assess aortic valve area (AVA) using parameters obtained exclusively from TEE as an alternative approach.

Methods: Thirty patients with equivocal AS based on TTE were evaluated using TEE for further assessment.

Results: The mean pressure gradient across the aortic valve (AV) was 38 ± 5.9 and 37.9 ± 7.6 mmHg in TTE and TEE, respectively, P = 0.42. LVOT-CSA was larger in TEE (3.6 ± 0.3 vs. 3.4 ± 0.3 cm2, P = 0.049). VTI over the AVA was similar (98.54 ± 22.8 and 99.52 ± 24.52 cm in TTE and TEE, respectively, P = 0.608), while VTI across the LVOT was higher when measured by TTE (24.06 ± 5.8 vs. 22.03 ± 4.3 cm, P < 0.009). Using the CE, AVA was 0.82 ± 0.3 vs. 0.83 ± 0.17 cm2 in TEE vs. TTE, respectively, P = 0.608. Definitive grading was achieved in all patients (26 patients defined with severe AS and 4 with moderate).

Conclusions: In equivocal cases of AS, full assessment using TEE may be a reliable modality for decision making.

August 2023
Maya Shina MD, Fabio Kusniec MD, Guy Rozen MD MHA, Shemy Carasso MD FESC FASE, David Planer MD, Ronny Alcalai MD, Liza Grosman-Rimon PhD, Gabby Elbaz-Greener MD MHA DRCPSC, Offer Amir MD FACC

Background: Among the most frequent complications following transcatheter aortic valve replacement (TAVR) is hemostasis imbalance that presents either as thromboembolic or bleeding. Deviations in platelet count (PC) and mean platelet volume (MPV) are markers of hemostasis imbalance.

Objectives: To determine the predictive value of pre- and post-procedural PC and MPV fL 1-year all-cause mortality in patients who underwent TAVR.

Methods: In this population-based study, we included 236 TAVR patients treated at the Tzafon Medical Center between 1 June 2015 and 31 August 2018. Routine blood samples for serum PC levels and MPV fL were taken just before the TAVR and 24-hour post-TAVR. We used backward regression models to evaluate the predictive value of PC and MPV in all-cause mortality in TAVR patients.

Results: In this study cohort, MPV levels 24-hour post-TAVR that were greater than the cohort median of 9 fL (interquartile range 8.5–9.8) were the strongest predictor of 1-year mortality (hazard ratio 1.343, 95% confidence interval 1.059–1.703, P-value 0.015). A statistically significant relationship was seen in the unadjusted regression model as well as after the adjustment for clinical variables.

Conclusions: Serum MPV levels fL 24-hour post-procedure were found to be meaningful markers in predicting 1-year all-cause mortality in patients after TAVR.

February 2023
Gassan Moady MD MPH, Alexander Shturman MD, Elias Daud MD, Gal Rubinstein MD, Dror Leviner MD, Shaul Atar MD

Takotsubo syndrome (TTS) often develops following stressors such as cardiac surgery. It may be fatal in rare cases. Our 70-year-old female patient presented with a rare case of tricuspid valve papillary fibroelastoma, which was complicated by fatal TTS after successful resection. The patient had a right atrial mass that was investigated with computed tomography and transesophageal echocardiography (TTE). She was scheduled for surgery. Pathology findings were consistent with papillary fibroelastoma of the tricuspid valve. Three weeks after successful surgery, the patient was admitted due to cardiogenic shock with echocardiographic findings of apical ballooning and left ventricular outflow tract obstruction consistent with TTS. The patient died one hour after her admission despite optimal medical therapy.

April 2022
Ilan Merdler MD MHA, Shir Frydman MD, Svetlana Sirota MSc, Amir Halkin MD, Arie Steinvil MD, Ella Toledano MD, Maayan Konigstein MD, Batia Litmanowicz MD, Samuel Bazan MD, Atalia Wenkert BA, Sapir Sadon BA, Shmuel Banai MD, Ariel Finkelstein MD, and Yaron Arbel MD

Background: Neutrophil-to-lymphocyte ratio (NLR) is a simple and cost-effective marker of inflammation. This marker has been shown to predict cardiac arrhythmias, progression of valvular heart disease, congestive heart failure decompensation, acute kidney injury, and mortality in cardiovascular patients. The pathologic process of aortic stenosis includes chronic inflammation of the valve and therefore biomarkers of inflammation might offer additive prognostic value.

Objectives: To evaluate NLR and its association with long term mortality in transcatheter aortic valve implantation (TAVI) patients.

Methods: We evaluated data of 1152 consecutive patient from the Tel Aviv Medical Center TAVI registry who underwent TAVI. Data included baseline clinical, demographic, and echocardiographic findings; procedural complications; and post-procedure mortality. Patients were compared by using the median NLR value (4.1) and evaluated for long-term mortality.

Results: Patients with NLR above the median had higher mortality rates (26.4% vs. 16.3%, P < 0.001) at 3 years post-procedure. A multivariable analysis found NLR to be an independent risk factor for mortality (hazard ratio = 1.47, 95% confidence interval 1.09–1.99, P = 0.013). In addition, high NLR was linked to complicationsduring and after the procedure.

Conclusion: NLR is an independent prognostic marker among TAVI patients. This marker may represent an increased inflammatory response and should be added to previous known prognostic factors.

March 2022
Zahi Abu Ghosh MD, Mony Shuvy MD, Ronen Beeri MD, Israel Gotsman MD, Batla Falah MD, Mahsati Ibrahimli MD, and Dan Gilon MD

Background: Cancer patients with heart failure (HF) and severe mitral regurgitation (MR) are often considered to be at risk for surgical mitral valve repair/replacement. Severe MR inducing symptomatic HF may prevent delivery of potentially cardiotoxic chemotherapy and complicate fluid management with other cancer treatments.

Objectives: To evaluate the outcome of percutaneous mitral valve repair (PMVR) in oncology patients with HF and significant MR.

Methods: Our study comprised 145 patients who underwent PMVR, MitraClip, at Hadassah Medical Center between August 2015 and September 2019, including 28 patients who had active or history of cancer. Data from 28 cancer patients were compared to 117 no-cancer patients from the cohort.

Results: There was no significant difference in the mean age of cancer patients and no-cancer patients (76 vs. 80 years, P = 0.16); 67% of the patients had secondary (functional) MR. Among cancer patients, 21 had solid tumor and 7 had hematologic malignancies. Nine patients (32%) had active malignancy at the time of PMVR. The mean short-term risk score of the patients was similar in the two groups, as were both 30-day and 1-year mortality rates (7% vs. 4%, P = 0.52) and (29% vs. 16%, P = 0.13), respectively.

Conclusion: PMVR in cancer patients is associated with similar 30-day and 1-year survival rate compared with patients without cancer. PMVR should be considered for cancer patients presenting with HF and severe MR and despite their malignancy. This approach may allow cancer patients to safely receive planned oncological treatment

Lian Bannon MD, Omer Shlezinger MD, Alexandra Nathan MD, Yan Topilsky MD, Ilan Merdler MD MHA, and Eihab Ghantous MD
December 2019
Oholi Tovia-Brodie MD, Sevan Letourneau-Shesaf MD, Aviram Hochstadt MD, Arie Steinvil MD, Raphael Rosso MD, Ariel Finkelstein MD and Yoav Michowitz MD

Background: Patients with right bundle branch block (RBBB) prior to transcatheter aortic valve implantation (TAVI) are at high risk for immediate post-procedural heart block and long-term mortality when discharged without a pacemaker.

Objectives: To test whether prophylactic permanent pacemaker implantation (PPI) is beneficial.

Methods: Of 795 consecutive patients who underwent TAVI, 90 patients had baseline RBBB. We compared characteristics and outcomes of the prophylactic PPI with post-TAVI PPI. Need for pacing was defined as  greater than 1% ventricular pacing.

Results: Forty patients with RBBB received a prophylactic PPI (group 1), and in 50 the decision was based on standard post-procedural indications (group 2). There were no significant differences in clinical baseline characteristics. One patient developed a tamponade after a PPI post-TAVI. A trend toward shorter hospitalization duration in group 1 patients was observed (P = 0.06). On long-term follow-up of 848 ± 56 days, no differences were found in overall survival (P = 0.77), the composite event-free survival of both mortality and hospitalizations (P = 0.66), or mortality and syncope (P = 0.65). On multivariate analysis, independent predictors of the need for pacing included baseline PR interval increase of 10ms (odds ratio [OR] 1.21 per 10 ms increment 95% confidence interval [95%CI] 1.02–1.44, P = 0.028), and the use of new generation valves (OR 3.92, 95%CI 1.23–12.46, P = 0.023).

Conclusions: In patients with baseline pre-TAVI RBBB, no outcome differences were found with prophylactic PPI. On multivariate analysis, predictors of the need for pacing included baseline long PR interval, and the use of newer generation valves.

September 2019
Arthur Shiyovich MD and Ran Kornowski MD FESC FACC

Aortic stenosis (AS) is a common valvular pathology and is increasing in prevalence. Severe symptomatic AS is associated with serious outcomes if left untreated. Transcatheter aortic valve implantation (TAVI) is an innovative modality, which has revolutionized the treatment of AS. With growing experience and technological upgrades, TAVI has become a valid alternative to surgical valve replacement. However, TAVI is associates with increase non-negligible risks of mortality, stroke, physical disability, and healthcare expenditures. Furthermore, imaging modalities have shown new ischemic lesions in most patients following TAVI (silent strokes), which might be related to worse subsequent neurocognitive function. Embolic protective devices are emerging as a safe, technically feasible implements to reduce the burden of periprocedural thromboembolism, and have shown promising results of improved clinical outcomes.

May 2019
Hussein Sliman MD, Avinoam Shiran MD, Dallit Mannheim MD, Eyal Avraham MD, Ron Karmeli MD, Nader Khader MD, Barak Zafrir MD, Ronen Rubinshtein MD and Ronen Jaffe MD

Background: Access-site bleeding is a common complication of transfemoral transcatheter aortic valve implantation (TAVI). Percutaneous stent-graft implantation within the femoral artery may achieve hemostasis and avert the need for more invasive surgical vascular repair; however, failure to advance a guidewire antegradely via the injured vessel may preclude stent delivery. While retrograde stent-graft delivery from the distal vasculature may potentially enable percutaneous control of bleeding, this approach has not been reported.

Objectives: To assess the feasibility of a retrograde approach for stent-graft implantation in the treatment of access-site bleeding following transfemoral TAVI.

Methods: A prospective TAVI registry was analyzed. Of 349 patients who underwent TAVI, transfemoral access was used in 332 (95%). Access-site injury requiring stent-graft implantation occurred in 56 (17%). In four patients (7%), antegrade wiring across the site of vascular injury was not possible and a retrograde approach for stent delivery was used.

Results: Distal vascular access was achieved via the superficial femoral or profunda artery. Retrograde advancement of a polymer-coated 0.035” wire to the abdominal aorta, followed by stent-graft delivery to the common femoral artery, achieved hemostasis in all cases. During a median (interquartile range) follow-up period of 198 (618) days (range 46–2455) there were no deaths and no patient required additional vascular interventions.

Conclusions: A retrograde approach for stent-graft delivery is feasible and allows percutaneous treatment of a common femoral artery injury following TAVI in patients who are not suitable for the conventional antegrade approach.

July 2018
Eilon Ram MD, Leonid Sternik MD, Alexander Lipey MD, Sagit Ben Zekry MD, Ronny Ben-Avi MD, Yaron Moshkovitz MD and Ehud Raanani MD

Background: Unicuspid and bicuspid aortic valve (BAV) are congenital cardiac anomalies associated with valvular dysfunction and aortopathies occurring at a young age.

Objectives: To evaluate our experience with aortic valve repair (AVr) in patients with bicuspid or unicuspid aortic valves.

Methods: Eighty patients with BAV or unicuspid aortic valve (UAV) underwent AVr. Mean patient age was 42 ± 14 years and 94% were male. Surgical technique included: aortic root replacement with or without cusp repair in 43 patients (53%), replacement of the ascending aorta at the height of the sino-tubular junction with or without cusp repair in 15 patients (19%), and isolated cusp repair in 22 patients (28%).

Results: The anatomical structure of the aortic valve was bicuspid in 68 (85%) and unicuspid in 12 patients (15%). Survival rate was 100% at 5 years of follow-up. Eleven patients (13.7%) underwent reoperation, 8 of whom presented with recurrent symptomatic aortic insufficiency (AI). Late echocardiography in the remaining 69 patients revealed mild AI in 63 patients, moderate recurrent AI in 4, and severe recurrent AI in 2. Relief from recurrent severe AI or reoperations was significantly lower in patients who underwent cusp repair compared with those who did not (P = 0.05). Furthermore, the use of pericardial patch augmentation for the repair was a predictor for recurrence (P = 0.05).

Conclusions: AVr in patients with BAV or UAV is a safe procedure with low morbidity and mortality rates. The use of a pericardial patch augmentation was associated with higher repair failure.

March 2017
Uri Landes MD, Arthur Kerner MD, Amit Segev MD, Haim Danenberg MD, Yaron Shapira MD, Ariel Finkelstein MD and Ran Kornowski MD FESC FACC

Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery. 

Objectives: To report the multicenter TVIV experience in Israel.

Methods: We approached multiple centers and collected data regarding seven TVIV cases. 

Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up. 

Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk. 

 

February 2016
Amjad Shalabi MD, Ehud Raanani MD, Amihai Shinfeld MD, Rafael Kuperstein MD, Alexander Kogan MD, Alexander Lipey MD, Eyal Nachum MD and Dan Spiegelstein MD

Background: Prolonged life expectancy has increased the number of elderly high risk patients referred for surgical aortic valve replacement (AVR). These referred high risk patients may benefit from sutureless bioprosthesis procedures which reduce mortality and morbidity.

Objectives: To present our initial experience with sutureless aortic bioprotheses, including clinical and echocardiographic results, in elderly high risk patients referred for AVR. 

Methods: Forty patients (15 males, mean age 78 ± 7 years) with symptomatic severe aortic stenosis underwent AVR with the 3F Enable™ or Perceval™ sutureless bioprosthesis during the period December 2012 to May 2014. Mean logistic EuroScore was 10 ± 3%. Echocardiography was performed preoperatively, intraoperatively, at discharge and at follow-up.

Results: There was no in-hospital mortality. Nine patients (22%) underwent minimally invasive AVR via a right anterior mini-thoracotomy and one patient via a J-incision. Four patients underwent concomitant coronary aortic bypass graft, two needed intraoperative repositioning of the valve, one underwent valve exchange due to inappropriate sizing, three (7.5%) had a perioperative stroke with complete resolution of neurologic symptoms, and one patient (2.5%) required permanent pacemaker implantation due to complete atrioventricular block. Mean preoperative and postoperative gradients were 44 ± 14 and 13 ± 5 mmHg, respectively. At follow-up, 82% of patients were in New York Heart Association functional class I and II.

Conclusions: Sutureless AVR can be used safely in elderly high risk patients with relatively low morbidity and mortality. The device can be safely implanted via a minimally invasive incision. Mid-term hemodynamic results are satisfactory, demonstrating significant clinical improvement.

 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel