• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


November 2024
Tamar Slobodov MD, Gergana Marincheva MD, Michael Rahkovich MD, Andrei Valdman MD, Yonatan Kogan MD, Avishag Laish-Farkash MD PhD

Background: Cardiac implantable electronic devices (CIEDs) with endocardial leads crossing the tricuspid valve can lead to or worsen tricuspid regurgitation (TR), causing substantial morbidity and mortality. Despite a recent randomized controlled study revealing a low short-term incidence of device-related TR (DRT) post-CIED implantation, uncertainties persist regarding the efficacy of intra-procedural 2-dimensional transthoracic echocardiography (2DTTE) in preventing long-term TR.

Objectives: To conduct a long-term follow-up study on patients with CIED implants based on a previous study conducted at our hospital.

Methods: In a retrospective study at Assuta Ashdod Medical Center (2018–2019), patients undergoing de-novo CIED implantation with (n=39, group 1) or without (n=51, group 2) intra-procedural 2DTTE were analyzed. Clinical, demographic, and long-term (> 1 year) echocardiographic data were collected and compared.

Results: The study included 90 patients (mean age 72.3 ± 11.0 years, 63% male, 23% ICD, 50% active leads, follow-up 32.8 ± 11 months). TR aggravation was found in 25% of patients (13 in group 1, 10 in group 2), with no statistical difference between groups. Multivariate analysis identified a history of atrial fibrillation (AF) as the sole significant factor in long-term TR deterioration (OR=3.44, 95%CI 1.13–10.43, P = 0.029). Other clinical, demographic, echocardiographic, and device-related factors did not significantly contribute to long-term DRT.

Conclusions: After one-year post-CIED implantation, the incidence of DRT significantly increases. Intra-procedural 2DTTE does not effectively reduce long-term DRT, suggesting that implantation-related mechanisms are less likely the primary cause. AF likely plays a major role in the pathogenesis of long-term TR in this subset post-CIED implantation.

October 2023
Zach Rozenbaum MD FACC FSCAI

Infectious endocarditis (IE) remains challenging to treat, with substantial morbidity and mortality rates. Antibiotics are the mainstay of treatment; however, patients with large vegetations often do not respond to antibiotics. Moreover, large vegetations carry an increased risk of embolization. In such cases, guidelines recommend considering surgical treatment [1]. Surgery itself introduces potential complications and high mortality rates [2], and if performed during active infection, the technical possibilities are hindered by a catastrophic recurrence on prosthetic material. Emerging percutaneous solutions to large IE vegetations have been described in recent years to overcome the surgical limitations. Currently, several devices are available. The different debulking mechanisms are based on percutaneous mechanical, either motor or manual aspiration. While becoming more available, percutaneous treatment options are not mentioned in guidelines and data are limited. This report describes a case of percutaneous tricuspid valve (TV) vegetation aspiration using Inari Flowtriever (Inari Medical, Irvine, CA, USA). The case is followed by a review of the literature.

February 2023
Gassan Moady MD MPH, Alexander Shturman MD, Elias Daud MD, Gal Rubinstein MD, Dror Leviner MD, Shaul Atar MD

Takotsubo syndrome (TTS) often develops following stressors such as cardiac surgery. It may be fatal in rare cases. Our 70-year-old female patient presented with a rare case of tricuspid valve papillary fibroelastoma, which was complicated by fatal TTS after successful resection. The patient had a right atrial mass that was investigated with computed tomography and transesophageal echocardiography (TTE). She was scheduled for surgery. Pathology findings were consistent with papillary fibroelastoma of the tricuspid valve. Three weeks after successful surgery, the patient was admitted due to cardiogenic shock with echocardiographic findings of apical ballooning and left ventricular outflow tract obstruction consistent with TTS. The patient died one hour after her admission despite optimal medical therapy.

January 2022
Gergana Marincheva MD, Tal Levi MD, Olga Perelshtein Brezinov MD, Andrei Valdman MD, Michael Rahkovich MD, Yonatan Kogan MD, and Avishag Laish-Farkash MD PhD

Background: Endocardial leads of permanent pacemakers (PPM) and implantable defibrillators (ICD) across the tricuspid valve (TV) can lead to tricuspid regurgitation (TR) or can worsen existing TR with subsequent severe morbidity and mortality.

Objectives: To evaluate prospectively the efficacy of intraprocedural 2-dimentional-transthoracic echocardiography (2DTTE) in reducing/preventing lead-associated TR.

Methods: We conducted a prospective randomized controlled study comparing echocardiographic results in patients undergoing de-novo PPM/ICD implantation with intraprocedural echo-guided right ventricular (RV) lead placement (Group 1, n=56) versus non-echo guided implantation (Group 2, n=55). Lead position was changed if TR grade was more than baseline in Group 1. Cohort patients underwent 2DTTE at baseline and 3 and/or 6 months after implantation. Excluded were patients with baseline TR > moderate or baseline ≥ moderate RV dysfunction.

Results: The study comprised 111 patients (74.14 ± 11 years of age, 58.6% male, 19% ICD, 42% active leads). In 98 patients there was at least one follow-up echo. Two patients from Group 1 (3.6%) needed intraprocedural RV electrode repositioning. Four patients (3.5%, 2 from each group, all dual chamber PPM, 3 atrial fibrillation, 2 RV pacing > 40%, none with intraprocedural reposition) had TR deterioration during 6 months follow-up. One patient from Group 2 with baseline mild-moderate aortic regurgitation (AR) had worsening TR and AR within 3 months and underwent aortic valve replacement and TV repair.

Conclusions: The rate of mechanically induced lead-associated TR is low; thus, a routine intraprocedural 2DTTE does not have a significant role in reducing/preventing it

December 2021
Ben Sadeh MD, Tamar Itach MD, Ilan Merdler MD MHA, Shir Frydman MD, Samuel Morgan BSc, David Zahler MD, Yogev Peri MD, Aviram Hochstadt MD MPH, Yotam Pasternak MD MSc, Yan Topilsky MD,Shmuel Banai MD, and Yacov Shacham MD

Background: Tricuspid regurgitation (TR) is associated with adverse prognosis in various patient populations, but currently no data is available about the prevalence and prognostic implication of TR in ST-segment elevation myocardial infarction (STEMI) patients.

Objectives: To investigate the possible implication of TR among STEMI patients.

Methods: We conducted a retrospective study of STEMI patients undergoing primary percutaneous coronary intervention (PCI) and its relation to major clinical and echocardiographic parameters. Patient records were assessed for the prevalence and severity of TR, its relation to the clinical profile, key echocardiographic parameters, in-hospital outcomes, and long-term mortality. Patients with previous myocardial infarction or known previous TR were excluded.

Results: The study included 1071 STEMI patients admitted between September 2011 and May 2016 (age 61 ± 13 years; predominantly male). A total of 205 patients (19%) had mild TR while another 32 (3%) had moderate or greater TR. Patients with significant TR demonstrated worse echocardiographic parameters, were more likely to have in-hospital complications, and had higher long-term mortality (28% vs. 6%; P < 0.001). Following adjustment for significant clinical and echocardiographic parameters, mortality hazard ratio of at least moderate to severe TR remained significant (hazard ratio 2.44; 95% confidence interval 1.06–5.62; P = 0.036) for patients with moderate-severe TR.

Conclusions: Among STEMI patients after primary PCI, the presence of moderate-severe TR was independently associated with adverse outcomes and significantly lower survival rate

July 2021
Ben Sadeh MD, Tamar Itach MD, Ilan Merdler MD MHA, Shir Frydman MD, Samuel Morgan BSc, David Zahler MD, Yogev Peri MD, Aviram Hochstadt MD, Yotam Pasternak MD MSc, Yan Topilsky MD, Shmuel Banai MD, and Yacov Shacham MD

Background: Tricuspid regurgitation (TR) is associated with adverse prognosis in various patient populations but currently no data is available about the prevalence and prognostic implication of TR in ST-segment elevation myocardial infarction (STEMI) patients.

Objectives: To investigate the possible implication of TR among STEMI patients.

Methods: We conducted a retrospective study of STEMI patients undergoing primary percutaneous coronary intervention (PCI), and its relation to major clinical and echocardiographic parameters. Patient records were assessed for the prevalence and severity of TR as well as the relation to the clinical profile, key echocardiographic parameters, in-hospital outcomes, and long-term mortality. Patients with previous myocardial infarction or known previous TR were excluded.

Results: The study included 1071 STEMI patients admitted between September 2011 and May 2016 (age 61 ± 13 years; predominantly male). A total of 205 patients (19%) had mild TR while another 32 (3%) had moderate or greater TR. Patients with significant TR demonstrated worse echocardiographic parameters, were more likely to have in-hospital complications, and had higher long-term mortality (28% vs. 6%, P < 0.001). Following adjustment for significant clinical and echocardiographic parameters, mortality hazard ratio of at least moderate to severe TR remained significant (2.44, 95% confidence interval 1.06–5.6, P = .036) for patients with moderate to severe TR.

Conclusions: Among STEMI patients after primary PCI, the presence of moderate to severe TR was independently associated with adverse outcomes and significantly lower survival rate

March 2017
Uri Landes MD, Arthur Kerner MD, Amit Segev MD, Haim Danenberg MD, Yaron Shapira MD, Ariel Finkelstein MD and Ran Kornowski MD FESC FACC

Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery. 

Objectives: To report the multicenter TVIV experience in Israel.

Methods: We approached multiple centers and collected data regarding seven TVIV cases. 

Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up. 

Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk. 

 

January 2016
Amir Givon MD, Natalia Vedernikova MD, David Luria MD, Ori Vatury MD, Rafael Kuperstein MD, Micha S. Feinberg MD, Michael Eldar MD, Michael Glikson MD and Eyal Nof MD

Background: Transvenous lead extraction can lead to tricuspid valve damage. 

Objectives: To assess the incidence, risk factors and clinical outcome of tricuspid regurgitation (TR) following lead extraction.

Methods: We prospectively collected data on patients who underwent lead extraction at the Sheba Medical Center prior to laser use (i.e., before 2012). Echocardiography results before and following the procedure were used to confirm TR worsening, defined as an echocardiographic increase of at least one TR grade. Various clinical and echocardiographic parameters were analyzed as risk factors for TR. Clinical and echocardiographic follow-up was conducted to assess the clinical significance outcome of extraction-induced TR.

Results: Of 152 patients who underwent lead extraction without laser before 2012, 86 (56%) (192 electrodes) had echocardiography results before and within one week following the procedure. New or worsening TR was discovered in 13 patients (15%). Use of mechanical tools and younger age at extraction were found on multivariate analysis to be factors for TR development (P = 0.04 and P = 0.03 respectively). Average follow-up was 22.25 ± 21.34 months (range 8–93). There were no significant differences in the incidence of right-sided heart failure (50% vs. 23%, P = 0.192) or hospitalizations due to heart failure exacerbations (37.5% vs. 11%, P = 0.110). No patient required tricuspid valve repair or replacement. Death rates were similar in the TR and non-TR groups (20% vs. 33%).

Conclusions: TR following lead extraction is not uncommon but does not seem to affect survival or outcomes such as need for valve surgery. Its long-term effects remain to be determined. 

 

December 2006
April 2001
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel