• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Thu, 21.11.24

Search results


June 2017
Noam Shohat MD, Dror Lindner MD, Eran Tamir MD, Yiftah Beer MD and Gabriel Agar MD

Background: The debate continues regarding the best way to manage partial anterior cruciate ligament (ACL) tears.

Objectives: To prospectively compare the clinical outcomes of remnant-preserving augmentation (RPA) and double-bundle reconstruction (DBR) in patients with ACL tears.

Methods: In this prospective study, we included 13 cases of RPA and 30 cases of DBR with a follow-up period of 6 months, 12 months and 24 months. We clinically compared the preoperative and postoperative range of motion, Knee Society Score (KSS), Visual Analog Scale (VAS), Lysholm score, Tegner activity score, Short Form Health Survey (SF-36), thigh and calf circumference and anterior translation (Using the KT-1000 knee arthrometer). 

Results: There were no significant differences in Lysholm score, Tegner score, VAS or KSS within the two groups at any time. The KT-1000 arthrometer results were higher in the RPA group at 6 months than in the DBR group; however, it did not reach statistical significance. 

Conclusions: We found no significant differences between the two specific groups leading us to believe that RPA may play a role in reconstruction when only a single bundle is injured.

 

October 2000
Valentin Fulga MD, Ben-Ami Sela PhD and Michael Belkin MA MD

Background: Most corneal damage induced by contact lenses is due to interference with corneal oxygenation.

Objective: To investigate the effect on the rabbit cornea of a rigid gas-permeable contact lens with a newly designed periphery.

Method: We fitted New Zealand white rabbits (n=12) with RGP[1] contact lenses that were identical in all respects except for the design of the periphery. In each animal, one contact lens had an innovative periphery consisting of a microscopic diffractive relief lathed on the back surface; the other contact lens was of a conventional design. The lenses were worn continuously for 7 days. During this experimental period and for 1 additional week we assessed the corneal damage by daily testing lactic dehydrogenase activity in the tears.

Results: On the last day of the experimental week and the first 3 days of the healing period, mean tear LDH[2] activity was significantly lower in the eyes with the new contact lens design than in eyes with the conventional lenses.

Conclusions: The novel periphery design reduces corneal damage resulting from contact lens wear, as reflected by LDH levels in the tears. The new design probably facilitates the flow and exchange of tears under the contact lens, resulting in improved metabolism of the cornea. These findings may also prove applicable to soft contact lenses.






[1] RGP = rigid gas permeable



[2] LDH = lactic dehydrogenase


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel