• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Thu, 21.11.24

Search results


September 2003
R. Greenberg, Y. Barnea, S. Schneebaum, H. Kashtan, O. Kaplan and Y. Skornik

Background: Drains are inserted in the dissected axilla of most patients during surgery for breast cancer.

Objective: To evaluate the presence and prognostic value of MUC1 and Met-HGF/SF in the axillary drainage of these patients.

Methods: The study group included 40 consecutive patients with invasive ductal carcinoma of the breast who were suitable for breast-conserving treatment; 20 malignant melanoma patients found to have negative axillary sentinel lymph node served as the control group. The output of the drains, which had been placed in the axilla during operation, was collected, and the presence of MUC1, Met-hepatocyte growth factor/scatter factor and b-actin were assessed in the lymphatic fluid by reverse transcription-polymerase chain reaction assays. The data were compared to the pathologic features of the tumor and the axillary lymph nodes, and to the estrogen and progesterone receptors status.

Results: RT-PCR[1] assays of the axillary lymphatic drainage were positive for MUC1 and Met-HGF/SF[2] in 15 (37.5%) and 26 (65%) of the patients, respectively. Patients in whom MUC1 and Met-HGF/SF were not found in the axillary fluid had smaller tumors and less capillary and lymphatic invasion, compared to patients with positive assays (P < 0.02 for all these comparisons). The lymph nodes were negative for metastases in all patients with negative assays (P < 0.001). The presence of MUC1 and Met-HGF/SF showed negative correlations with the estrogen and progesterone receptors (P < 0.05).

Conclusion: MUC1 and Met-HGF/SF can be detected in the axillary fluids of patients with breast cancer. The expression of both tumor markers in the axillary drainage is strongly associated with unfavorable tumor features and can be used as a prognostic factor.






[1] RT-PCR = reverse transcription-polymerase chain reaction



[2] HGF/SF = hepatocyte growth factor/scatter factor


June 2003
B. Nageris, D. Guttman, G. Bahar, M. Melloul, S. Schneebaum and R. Feinmesser

Background: Technetium-99m sestamibi scintigraphy has become one of the most popular techniques for localization of the parathyroid gland after failure of primary neck exploration.

Objective: To examine the efficacy of sestamibi with the hand-held gamma ray detecting probe for the identification of parathyroid adenomas during revision parathyroidectomy.

Methods: We reviewed six cases of probe-assisted neck exploration for parathyroid lesions following unsuccessful primary exploration.

Results: In all cases, the pathologic glands were successfully detected and removed.

Conclusions: With careful planning, a gamma ray detecting probe can be used optimally at 2–3 hours after technetium-99m sestamibi injection. The probe is efficient, easy and convenient to use.
 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel