Ada Rosen MD, Sorin Elias MD, Hadas Ganer Herman MD, Alexander Condrea MD, and Shimon Ginath MD

Background: The current approach to performing sacral neuromodulation consists of a two-stage procedure, the first of which includes insertion of the sacral electrode under fluoroscopic visualization of the S3 foramen. Alternatively, in certain situations computed tomography (CT)-guided insertion can be used.

Objectives: To evaluate the use of CT in cases of reinsertion of the electrode due to infection, dislocation, or rupture.

Methods: Medical records of patients who underwent neuromodulation device reinsertion between 2005 and 2016 for fecal incontinence were reviewed. Study outcomes included procedure course, successful placement, and long-term treatment success.

Results: During the study period, we inserted a neuromodulation device in 67 patients. A CT-guided insertion of a sacral electrode was performed in 10 patients. In nine patients, the insertion and the final location of the electrode were successful. In one patient, the electrode migrated upward due to a malformation of the S3 foramen on both sides and had to be placed in S4. In a mean follow-up of 68.4 ± 30.0 months following the re-insertion, there was a significant reduction in the number of incontinence episodes per day (P < 0.001) and the number of pads used per day (P = 0.002).

Conclusions: CT-guided insertion of a sacral electrode is a safe and promising option, especially in recurrent and or selected cases

March 2021
Moran Slavin MD, Shmuel Avital MD, Yael Einbinder MD, Barak Benjamin MD, and Roye Inbar MD

Background: Peritoneal dialysis (PD) is a treatment option for patients with end-stage renal disease (ESRD) and cardiorenal syndrome (CRS).

Objectives: To evaluate the outcome of this patient population.

Methods: A retrospective study was conducted of patients who underwent an open or laparoscopic insertion of a PD catheter at our institution between 2009 and 2017. Data included demographics, peri-operative parameters, and long-term outcome. Patient and technique survival curves are presented, including subgroup analysis by method of catheter insertion and techniques for infection prevention.

Results: The study population included 95 men and 42 women, aged 65.7 ± 12.4 years. Mean follow-up was 34.6 ± 27.3 months. Open insertion was performed in 113 cases, while 24 underwent laparoscopic insertion. There was no difference in technique survival between these groups (P = 0.943). Removal of the catheter was required in 66% of patients. Median technique survival was 12.1 months. Two-year technique survival was 37% and 5-year technique survival was 12%. The leading cause for catheter removal was infection (69%). Application of measures for prevention of infections were significantly associated with prolonged technique survival (P = 0.001). Technique survival after 2 years was 38% with the application of a single measure and 57% with the application of two measures (P = 0.001). CRS patients (n=24) had a significantly lower overall survival rate (2-year survival 20% vs. 74%, P = 0.001).

Conclusions: The method of catheter insertion has no effect on technique survival. Prevention of infections is the most significant factor for improving the technique survival rates.

March 2013
A. Ber and D.S. Seidman
 Background: The insertion of a levonorgestrel-releasing intrauterine system (LNG-IUS) requires experience and is associated with a low failure rate.

Objectives: To assess the reasons given by gynecologists why they failed to insert a LNG-IUS.

Methods: We obtained data from the sole distributor in Israel that prospectively recorded these cases when contacted by gynecologists following an insertion failure.

Results: The mean rate of failed insertions was 0.95% (range 0.77–1.03%) for the 5 year study period 2006–2010. The most common reasons reported by gynecologists for LNG-IUS insertion failure were loss of sterility of the device, inability to insert the device due to a stenotic cervical canal, accidental removal of the device following a successful insertion due to hasty removal of the inserter or the use of blunt scissors, and removal of the newly inserted LNG-IUS following ultrasound evidence that it was misplaced.

Conclusions:  Gynecologists should be aware of the common pitfalls associated with insertion of an LNG-IUS. Several techniques that may aid in avoiding these mishaps are described.

April 2011
R. Inbar, E. Santo, A. El-Abid Subchi, J. Korianski, Z. Halperin, R. Greenberg and S. Avital

 

Background: Esophageal perforations and postoperative esophageal leaks are associated with substantial morbidity and mortality and pose a difficult therapeutic challenge. 

Objectives: To evaluate the outcome of removable self-expanding metallic stents (SEMS) as a treatment for postoperative leaks and perforations of the esophagus and stomach.

Methods: We conducted a retrospective study of all patients in one medical center who underwent temporary insertion of a covered plastic stent for postoperative leaks and perforations of the esophagus and stomach from June 2009 to February 2010. Data were retrieved from hospital and outpatient clinical data charts. Data included indication for insertion, post-insertion outcome including stent complications, and follow-up after stent removal.

Results: The indications for stent insertion were postoperative leak in four patients and postoperative esophagopleural fistula in one patient. Three of the patients had a leak at the gastro-esophageal junction following laparoscopic sleeve gastrectomy. In all cases the stent insertion was completed successfully. In three patients the stent migrated distally. In two of these three it was repositioned or replaced endoscopically, and in the third it was excreted in the feces. Stents were removed electively after 6 to 7 weeks. All patients recovered fully and were discharged from the hospital.

Conclusions: SEMS insertion may have an important role in the management of postoperative leaks and perforations of the esophagus and stomach and should be considered in such cases.
 

October 2004
Y. Levy, O. Shovman, C. Granit, D. Luria, O. Gurevitz, D. Bar-Lev, M. Eldar, Y. Shoenfeld and M. Glikson

Background: The appearance of pericarditis following insertion of a permanent pacemaker is not widely acknowledged in the literature.

Objectives: To describe our experience with pericarditis following 395 permanent pacemaker implantations over 2 years.

Methods: We retrospectively reviewed the medical records of 395 consecutive patients in whom new pacing systems or pacemaker leads had been implanted over a 2 year period. We searched the records for pericarditis that developed within 1 month after pacemaker implantation according to the ICD-9 code. The incidence, clinical picture, response to treatment and relationship to lead design and location were studied.

Results: Eight cases (2%) of pericarditis following implantation were detected. Clinical manifestations in all patients were similar to those of post-pericardiotomy syndrome and included chest pain (n=7), friction rub (n=1), fever (n=2), fatigue (n=2), pleural effusion (n=2), new atrial fibrillation (n=2), elevated erythrocyte sedimentation rate (n=4) and echcardiographic evidence of pericardial effusion (n=8). All affected patients had undergone active fixation (screw-in) lead implantation in the atrial position. The incidence of pericarditis with screw-in atrial leads was 3% compared to 0% in other cases (P < 0.05).

Conclusions: Pericarditis is not uncommon following pacemaker implantation with active fixation atrial leads. Special attention should be paid to identifying pericardial complications following pacemaker implantation, especially when anticoagulant therapy is resumed or initiated. The use of passive fixation leads is likely to reduce the incidence of pericarditis but this issue should be further investigated.

November 2002
Ernest Beutler, MD and Carol West

Background: Gaucher disease results from the accumulation of glucosylceramide (glucocerebroside) in tissues of affected persons. Patients sharing the same genotype present with widely varying degrees of lipid storage and of clinical manifestations.

Objectives: To determine whether variation in the glucosylceramide synthase (UDPGlucose ceramide glucosyltransferase) gene, which encodes the enzyme that regulates the synthesis of glucocerebroside, could account for the variability and clinical manifestations.

Methods: Patients homozygous for the 1226G (N370S) mutation, the most common in the Ashkenazi Jewish population, were investigated. The exons and flanking sequences of the gene were sequenced using DNA derived from five very mild Gaucher disease patients and four patients with relatively severe Gaucher disease. Results: One polymorphism was found in the coding region, but this did not change any amino acids. Seven other polymorphisms were found in introns and in the 5' untranslated region. Some of these were single nucleotide polymorphisms; others were insertions. The mutations appear to be in linkage equilibrium and none were found with a significantly higher frequency in either severe or mildly affected individuals.

Conclusions: Mutations in the glucosylceramide synthase gene do not appear to count for the variability in expression of the common Jewish Gaucher disease mutation.
 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel