February 2020
Gideon Charach MD, Eli Karniel MD, Itamar Grosskopf MD and Lior Charach MD

Background: Internal thoracic impedance (ITI) measurement is a sensitive method for detecting preclinical pulmonary edema and pleural effusion.

Objectives: To investigate the efficacy of this non-invasive method for detecting early pleural effusion among geriatric patients and to monitor increased ITI during its resolution.

Methods: This prospective, controlled study was conducted between July 2012 and August 2015. The study comprised 70 patients aged 65 to 94 years; and 39 of the patients had pleural effusion. ITI was measured continuously with a RS-207 monitor. The predictive value of ITI monitoring was determined based on a total of eight measurements taken at 12-hour intervals over 84 hours.

Results: As a result of medical treatment, the median ITI of the study group increased from 31 (interquartile range [IQR] 28–33 ohms) to 41 ohms (IQR 38–41 ohms; P < 0.001) compared to non-significant changes in the control group. Average respiratory rate (per minute) in the study group decreased from 29 (IQR 28–34) to 19 (IQR 18–20).

Conclusions: ITI monitoring is efficient for diagnosis and for ongoing clinical evaluation of the treatment of elderly patients with pleural effusion. Timely treatment may prevent serious complications of effusions avoiding extended hospitalization.

October 2005
E. Zimlichman, A. Lahad, A. Aron-Maor, A. Kanevsky and Y. Shoenfeld.
 Background: As complementary and alternative medicine is gaining popularity among health consumers, diagnostic screening tools based on neuroreflexology are also being developed. These techniques, which are based on the rationale that measurement of electrical impedance of specific dermatomes reflects corresponding internal organ pathologies, have not yet been the subject of conventional scientific research.

Objectives: To determine the effectiveness of a neuroreflexology-based screening test, specifically the Medex device (Medex Screen Ltd.), for diagnosing patients undergoing conventional internal organ assessment, in a hospital setting.

Methods: Patients admitted to an internal medicine department, who met the inclusion criteria and agreed to participate, underwent conventional medical evaluation that included past medical history and physical examination. Another examination was conducted by a second physician using the Medex device to determine internal organ pathologies. A third researcher compared the actual “conventional” diagnosis with the Medex device output using standard statistical analysis.   

Results: Overall, 150 patients participated in the study. Correlation was significant for all categories (P < 0.01) except for blood and lymphatic disease. A high sensitivity (>70%) was measured for cardiovascular, respiratory, gastrointestinal and genitourinary diseases. The highest measure of agreement, as represented by the Cohen-Kappa factor, was found for respiratory disease (0.57).

Conclusions: Although the exact mechanism is not entirely clear, measurement of electroskin impedance of dermal-visceral zones has the potential to serve as a screening tool for inner organ pathologies. Further research should be conducted to create more evidence to support or dispute the use of this technique as a reliable diagnostic tool.