Inappropriate implantable cardiac defibrillator (ICD) shock due to electromagnetic interference (EMI) induced by electrocautery is a well-known theoretical association but is rarely reported [1]. We report a case of EMI induced by electrocautery causing inappropriate ICD shock, underlining that, with the use of monopolar cautery, not only the location of the surgery but also electrodispersive pad (EDP) placement may be important to avoid EMI.

August 2001
Yehiel Ziv, MD, Tamar Brosh, PhD, Gili Lushkov, MSc and Ariel Halevy, MD, FACS,

Background: The method of midline Iaparotomy incision and closure remains a complex surgical problem.

Objective: To compare the mechanical properties at the interface of midline laparotomy incision made by scalpel versus electrocutting current in rats.

Methods: A sharp midline laparotomy incision was made in 60 Wistar female rats using a scalpel or electrocautery to open the fascia. The fascial and skin wounds were closed separately with a continuous nylon. Fascial specimens were analyzed for mechanical properties at the midline incision using a loading machine. The load-extension curve was recorded during tensile loading at a steady extension rate of 15 mm/mm.

Results: There was no statistically significant difference between the two groups in either wound-bursting force (PPEAK) or the strain energy spent until the point of measured PPEAK. Each load-extension curve showed a characteristic pattern in all rats. Tissue stiffness was greater in the scalpel group than in the electrocautery group (P= 0.02). Correlations were found between tissue stiffness and strain energy, between tissue stiffness and bursting force, and between bursting force and strain energy.

Conclusions: While tissue stiffness was greater when a scalpel was used compared to electrocutting to incise the midline abdominal fascia in rats, there was no difference in the bursing force required to disrupt the wound.