Background: Open repair of the Achilles tendon is still the gold standard for treating rupture. This technique has the disadvantage of a long and problematic operative scar and thickly scarred Achilles tendon. To improve the surgical outcome minimally invasive techniques have been developed.
Objectives: To analyze our results of Achilles tendon repair using the Achillon® device and compare them with published studies.
Methods: We performed surgical repair of the Achilles tendon in 28 patients during a 4 year period (2004–2008): 14 patients were treated with the Achillon device, 12 with the open suture technique and 2 with the percutaneous method. Fourteen patients were available for follow-up: the tendon was repaired in 9 patients with the Achillon device, in 3 patients with open suturing and in 2 patients with the percutaneous technique. Follow-up ranged from 1 to 4 years.
Results: The average score of the AOFAS Ankle-Hindfoot Scale for the group treated with the Achillon device was 95.6 points (range 84–100) and for the group treated with the open method, 90 points (range 84–98). The length of the scar in patients operated with a minimally invasive technique was 3.81 cm (range 1–6 cm) as compared to 9.16 cm (range 8–10.5 cm) with the open suture.
Conclusions: This is the first review on this procedure in Israel. Excellent functional results were achieved with this technique. Our outcomes were similar to those of two other studies.