March 2017
Uri Landes MD, Arthur Kerner MD, Amit Segev MD, Haim Danenberg MD, Yaron Shapira MD, Ariel Finkelstein MD and Ran Kornowski MD FESC FACC

Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery. 

Objectives: To report the multicenter TVIV experience in Israel.

Methods: We approached multiple centers and collected data regarding seven TVIV cases. 

Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up. 

Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk. 

 

August 2013
A. Segev, D. Spiegelstein, P. Fefer, A. Shinfeld, I. Hay, E. Raanani and V. Guetta

Background: Trans-catheter aortic valve implantation (TAVI) has emerged as a novel therapeutic approach for patients with severe tricuspid aortic stenosis (AS) not suitable for aortic valve replacement.

Objectives: To describe our initial single-center experience with TAVI in patients with "off-label" indications.

Methods: Between August 2008 and December 2011 we performed TAVI in 186 patients using trans-femoral, trans-axillary, trans-apical and trans-aortic approaches. In 11 patients (5.9%) TAVI was undertaken due to: a) pure severe aortic regurgitation (AR) (n=2), b) prosthetic aortic valve (AV) failure (n=5), c) bicuspid AV stenosis (n=2), and d) prosthetic valve severe mitral regurgitation (MR) (n=2).

Results: Implantation was successful in all: six patients received a CoreValve and five patients an Edwards-Sapien valve. In-hospital mortality was 0%. Valve hemodynamics and function were excellent in all patients except for one who received an Edwards-Sapien that was inside a Mitroflow prosthetic AV and led to consistently high trans-aortic gradients. No significant residual regurgitation in AR and MR cases was observed.
Conclusions: TAVI is a good alternative to surgical AV replacement in high risk or inoperable patients with severe AS. TAVI for non-classical indications such as pure AR, bicuspid AV, and failed prosthetic aortic and mitral valves is feasible and safe and may be considered in selected patients. 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel