• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Wed, 17.07.24

Search results


November 2023
Gassan Moady MD, Moanis Serhan MD, Shaul Atar MD, Alexander Shturman MD

Background: The continuity equation (CE) used for evaluating aortic stenosis (AS) is based on values obtained from transthoracic echocardiography (TTE) with the assumption that the left ventricular outflow tract (LVOT) has a circular shape. Transesophageal echocardiography (TEE) may be used for accurate measurement of the LVOT cross-sectional area (CSA). Previous studies have focused on fusion from TEE for LVOT-CSA measurement and TTE for velocity time integrals (VTI) calculations.

Objectives: To assess aortic valve area (AVA) using parameters obtained exclusively from TEE as an alternative approach.

Methods: Thirty patients with equivocal AS based on TTE were evaluated using TEE for further assessment.

Results: The mean pressure gradient across the aortic valve (AV) was 38 ± 5.9 and 37.9 ± 7.6 mmHg in TTE and TEE, respectively, P = 0.42. LVOT-CSA was larger in TEE (3.6 ± 0.3 vs. 3.4 ± 0.3 cm2, P = 0.049). VTI over the AVA was similar (98.54 ± 22.8 and 99.52 ± 24.52 cm in TTE and TEE, respectively, P = 0.608), while VTI across the LVOT was higher when measured by TTE (24.06 ± 5.8 vs. 22.03 ± 4.3 cm, P < 0.009). Using the CE, AVA was 0.82 ± 0.3 vs. 0.83 ± 0.17 cm2 in TEE vs. TTE, respectively, P = 0.608. Definitive grading was achieved in all patients (26 patients defined with severe AS and 4 with moderate).

Conclusions: In equivocal cases of AS, full assessment using TEE may be a reliable modality for decision making.

August 2023
Maya Shina MD, Fabio Kusniec MD, Guy Rozen MD MHA, Shemy Carasso MD FESC FASE, David Planer MD, Ronny Alcalai MD, Liza Grosman-Rimon PhD, Gabby Elbaz-Greener MD MHA DRCPSC, Offer Amir MD FACC

Background: Among the most frequent complications following transcatheter aortic valve replacement (TAVR) is hemostasis imbalance that presents either as thromboembolic or bleeding. Deviations in platelet count (PC) and mean platelet volume (MPV) are markers of hemostasis imbalance.

Objectives: To determine the predictive value of pre- and post-procedural PC and MPV fL 1-year all-cause mortality in patients who underwent TAVR.

Methods: In this population-based study, we included 236 TAVR patients treated at the Tzafon Medical Center between 1 June 2015 and 31 August 2018. Routine blood samples for serum PC levels and MPV fL were taken just before the TAVR and 24-hour post-TAVR. We used backward regression models to evaluate the predictive value of PC and MPV in all-cause mortality in TAVR patients.

Results: In this study cohort, MPV levels 24-hour post-TAVR that were greater than the cohort median of 9 fL (interquartile range 8.5–9.8) were the strongest predictor of 1-year mortality (hazard ratio 1.343, 95% confidence interval 1.059–1.703, P-value 0.015). A statistically significant relationship was seen in the unadjusted regression model as well as after the adjustment for clinical variables.

Conclusions: Serum MPV levels fL 24-hour post-procedure were found to be meaningful markers in predicting 1-year all-cause mortality in patients after TAVR.

April 2022
Ilan Merdler MD MHA, Shir Frydman MD, Svetlana Sirota MSc, Amir Halkin MD, Arie Steinvil MD, Ella Toledano MD, Maayan Konigstein MD, Batia Litmanowicz MD, Samuel Bazan MD, Atalia Wenkert BA, Sapir Sadon BA, Shmuel Banai MD, Ariel Finkelstein MD, and Yaron Arbel MD

Background: Neutrophil-to-lymphocyte ratio (NLR) is a simple and cost-effective marker of inflammation. This marker has been shown to predict cardiac arrhythmias, progression of valvular heart disease, congestive heart failure decompensation, acute kidney injury, and mortality in cardiovascular patients. The pathologic process of aortic stenosis includes chronic inflammation of the valve and therefore biomarkers of inflammation might offer additive prognostic value.

Objectives: To evaluate NLR and its association with long term mortality in transcatheter aortic valve implantation (TAVI) patients.

Methods: We evaluated data of 1152 consecutive patient from the Tel Aviv Medical Center TAVI registry who underwent TAVI. Data included baseline clinical, demographic, and echocardiographic findings; procedural complications; and post-procedure mortality. Patients were compared by using the median NLR value (4.1) and evaluated for long-term mortality.

Results: Patients with NLR above the median had higher mortality rates (26.4% vs. 16.3%, P < 0.001) at 3 years post-procedure. A multivariable analysis found NLR to be an independent risk factor for mortality (hazard ratio = 1.47, 95% confidence interval 1.09–1.99, P = 0.013). In addition, high NLR was linked to complicationsduring and after the procedure.

Conclusion: NLR is an independent prognostic marker among TAVI patients. This marker may represent an increased inflammatory response and should be added to previous known prognostic factors.

March 2022
Lian Bannon MD, Omer Shlezinger MD, Alexandra Nathan MD, Yan Topilsky MD, Ilan Merdler MD MHA, and Eihab Ghantous MD
December 2019
Oholi Tovia-Brodie MD, Sevan Letourneau-Shesaf MD, Aviram Hochstadt MD, Arie Steinvil MD, Raphael Rosso MD, Ariel Finkelstein MD and Yoav Michowitz MD

Background: Patients with right bundle branch block (RBBB) prior to transcatheter aortic valve implantation (TAVI) are at high risk for immediate post-procedural heart block and long-term mortality when discharged without a pacemaker.

Objectives: To test whether prophylactic permanent pacemaker implantation (PPI) is beneficial.

Methods: Of 795 consecutive patients who underwent TAVI, 90 patients had baseline RBBB. We compared characteristics and outcomes of the prophylactic PPI with post-TAVI PPI. Need for pacing was defined as  greater than 1% ventricular pacing.

Results: Forty patients with RBBB received a prophylactic PPI (group 1), and in 50 the decision was based on standard post-procedural indications (group 2). There were no significant differences in clinical baseline characteristics. One patient developed a tamponade after a PPI post-TAVI. A trend toward shorter hospitalization duration in group 1 patients was observed (P = 0.06). On long-term follow-up of 848 ± 56 days, no differences were found in overall survival (P = 0.77), the composite event-free survival of both mortality and hospitalizations (P = 0.66), or mortality and syncope (P = 0.65). On multivariate analysis, independent predictors of the need for pacing included baseline PR interval increase of 10ms (odds ratio [OR] 1.21 per 10 ms increment 95% confidence interval [95%CI] 1.02–1.44, P = 0.028), and the use of new generation valves (OR 3.92, 95%CI 1.23–12.46, P = 0.023).

Conclusions: In patients with baseline pre-TAVI RBBB, no outcome differences were found with prophylactic PPI. On multivariate analysis, predictors of the need for pacing included baseline long PR interval, and the use of newer generation valves.

September 2019
Arthur Shiyovich MD and Ran Kornowski MD FESC FACC

Aortic stenosis (AS) is a common valvular pathology and is increasing in prevalence. Severe symptomatic AS is associated with serious outcomes if left untreated. Transcatheter aortic valve implantation (TAVI) is an innovative modality, which has revolutionized the treatment of AS. With growing experience and technological upgrades, TAVI has become a valid alternative to surgical valve replacement. However, TAVI is associates with increase non-negligible risks of mortality, stroke, physical disability, and healthcare expenditures. Furthermore, imaging modalities have shown new ischemic lesions in most patients following TAVI (silent strokes), which might be related to worse subsequent neurocognitive function. Embolic protective devices are emerging as a safe, technically feasible implements to reduce the burden of periprocedural thromboembolism, and have shown promising results of improved clinical outcomes.

May 2019
Hussein Sliman MD, Avinoam Shiran MD, Dallit Mannheim MD, Eyal Avraham MD, Ron Karmeli MD, Nader Khader MD, Barak Zafrir MD, Ronen Rubinshtein MD and Ronen Jaffe MD

Background: Access-site bleeding is a common complication of transfemoral transcatheter aortic valve implantation (TAVI). Percutaneous stent-graft implantation within the femoral artery may achieve hemostasis and avert the need for more invasive surgical vascular repair; however, failure to advance a guidewire antegradely via the injured vessel may preclude stent delivery. While retrograde stent-graft delivery from the distal vasculature may potentially enable percutaneous control of bleeding, this approach has not been reported.

Objectives: To assess the feasibility of a retrograde approach for stent-graft implantation in the treatment of access-site bleeding following transfemoral TAVI.

Methods: A prospective TAVI registry was analyzed. Of 349 patients who underwent TAVI, transfemoral access was used in 332 (95%). Access-site injury requiring stent-graft implantation occurred in 56 (17%). In four patients (7%), antegrade wiring across the site of vascular injury was not possible and a retrograde approach for stent delivery was used.

Results: Distal vascular access was achieved via the superficial femoral or profunda artery. Retrograde advancement of a polymer-coated 0.035” wire to the abdominal aorta, followed by stent-graft delivery to the common femoral artery, achieved hemostasis in all cases. During a median (interquartile range) follow-up period of 198 (618) days (range 46–2455) there were no deaths and no patient required additional vascular interventions.

Conclusions: A retrograde approach for stent-graft delivery is feasible and allows percutaneous treatment of a common femoral artery injury following TAVI in patients who are not suitable for the conventional antegrade approach.

July 2018
Eilon Ram MD, Leonid Sternik MD, Alexander Lipey MD, Sagit Ben Zekry MD, Ronny Ben-Avi MD, Yaron Moshkovitz MD and Ehud Raanani MD

Background: Unicuspid and bicuspid aortic valve (BAV) are congenital cardiac anomalies associated with valvular dysfunction and aortopathies occurring at a young age.

Objectives: To evaluate our experience with aortic valve repair (AVr) in patients with bicuspid or unicuspid aortic valves.

Methods: Eighty patients with BAV or unicuspid aortic valve (UAV) underwent AVr. Mean patient age was 42 ± 14 years and 94% were male. Surgical technique included: aortic root replacement with or without cusp repair in 43 patients (53%), replacement of the ascending aorta at the height of the sino-tubular junction with or without cusp repair in 15 patients (19%), and isolated cusp repair in 22 patients (28%).

Results: The anatomical structure of the aortic valve was bicuspid in 68 (85%) and unicuspid in 12 patients (15%). Survival rate was 100% at 5 years of follow-up. Eleven patients (13.7%) underwent reoperation, 8 of whom presented with recurrent symptomatic aortic insufficiency (AI). Late echocardiography in the remaining 69 patients revealed mild AI in 63 patients, moderate recurrent AI in 4, and severe recurrent AI in 2. Relief from recurrent severe AI or reoperations was significantly lower in patients who underwent cusp repair compared with those who did not (P = 0.05). Furthermore, the use of pericardial patch augmentation for the repair was a predictor for recurrence (P = 0.05).

Conclusions: AVr in patients with BAV or UAV is a safe procedure with low morbidity and mortality rates. The use of a pericardial patch augmentation was associated with higher repair failure.

February 2016
Amjad Shalabi MD, Ehud Raanani MD, Amihai Shinfeld MD, Rafael Kuperstein MD, Alexander Kogan MD, Alexander Lipey MD, Eyal Nachum MD and Dan Spiegelstein MD

Background: Prolonged life expectancy has increased the number of elderly high risk patients referred for surgical aortic valve replacement (AVR). These referred high risk patients may benefit from sutureless bioprosthesis procedures which reduce mortality and morbidity.

Objectives: To present our initial experience with sutureless aortic bioprotheses, including clinical and echocardiographic results, in elderly high risk patients referred for AVR. 

Methods: Forty patients (15 males, mean age 78 ± 7 years) with symptomatic severe aortic stenosis underwent AVR with the 3F Enable™ or Perceval™ sutureless bioprosthesis during the period December 2012 to May 2014. Mean logistic EuroScore was 10 ± 3%. Echocardiography was performed preoperatively, intraoperatively, at discharge and at follow-up.

Results: There was no in-hospital mortality. Nine patients (22%) underwent minimally invasive AVR via a right anterior mini-thoracotomy and one patient via a J-incision. Four patients underwent concomitant coronary aortic bypass graft, two needed intraoperative repositioning of the valve, one underwent valve exchange due to inappropriate sizing, three (7.5%) had a perioperative stroke with complete resolution of neurologic symptoms, and one patient (2.5%) required permanent pacemaker implantation due to complete atrioventricular block. Mean preoperative and postoperative gradients were 44 ± 14 and 13 ± 5 mmHg, respectively. At follow-up, 82% of patients were in New York Heart Association functional class I and II.

Conclusions: Sutureless AVR can be used safely in elderly high risk patients with relatively low morbidity and mortality. The device can be safely implanted via a minimally invasive incision. Mid-term hemodynamic results are satisfactory, demonstrating significant clinical improvement.

 

January 2016
Eyal R. Nachum MD, Ehud Raanani MD, Amit Segev MD, Victor Guetta MD, Ilan Hai MD, Amihai Shinfeld MD, Paul Fefer MD, Hamdan Ashraf MD, Israel Barabash MD, Amjad Shalabi MD and Dan Spiegelstein MD

Background: The rate of mitral bioprosthesis implantation in clinical practice is increasing. Transcatheter valve-in-valve implantation has been described for high risk patients requiring redo valve surgery. 

Objectives: To report our experience with transapical valve-in-valve implantation for failed mitral bioprosthesis.

Methods: Since 2010, 10 patients have undergone transapical valve-in-valve implantation for failed bioprosthesis in our center. Aortic valve-in-valve implantation was performed in one of them and mitral valve-in-valve implantation in nine. Mean age was 82 ± 4 years and 6 were female (67%). Mean time from original mitral valve (MV) replacement to valve-in-valve procedure was 10.5 ± 3.7 years. Follow-up was completed by all patients with a mean duration of 13 ± 12 months. 

Results: Preoperatively, all patients presented with significant mitral regurgitation; two with mitral stenosis due to structural valve failure. All nine patients underwent successful transapical valve-in-valve implantation with an Edwards Sapien™ balloon expandable valve. There was no in-hospital mortality. Mean and median hospital duration was 15 ± 18 and 7 days respectively. Valve implantation was successful in all patients and there were no major complications, except for major femoral access bleeding in one patient. At last follow-up, all patients were alive and in NYHA functional class I or II. Echocardiography follow-up demonstrated that mitral regurgitation was absent or trivial in seven patients and mild in two. At follow-up, peak and mean gradients changed from 26 ± 4 and 8 ± 2 at baseline to 16.7 ± 3 and 7.3 ± 1.5, respectively.

Conclusions: Transcatheter transapical mitral valve-in-valve implantation for failed bioprosthesis is feasible in selected high risk patients. Our early experience with this strategy is encouraging. Larger randomized trials with long-term clinical and echocardiographic follow-up are recommended.

 

December 2015
Orly Goitein MD, Elio Di Segni MD, Yael Eshet MD, Victor Guetta MD, Amit Segev MD, Eyal Nahum MD, Ehud Raanani MD, Eli Konen MD and Ashraf Hamdan MD

Background: Trans-catheter valve implantation (TAVI) is a non-surgical alternative for patients with severe aortic stenosis (AS). Pre-procedural computed tomography angiography (CTA) allows accurate “road mapping,” aortic annulus sizing and the detection of incidental findings.

Objectives: To document the prevalence of non-valvular extra-cardiac findings on CTA prior to TAVI and the impact of these findings on the procedure.  

Methods: Ninety AS patients underwent CTA as part of pre-TAVI planning. Scans extended from the clavicles to the groin. Non-vascular non-valvular findings were documented and graded as follows: (A) significant findings causing TAVI cancellation or postponement, (B) significant findings leading to a change in the TAVI procedure approach, (C) non-significant findings not affecting the TAVI procedure. 

Results: TAVI was planned for 90 patients; their average age was 80.2 ± 7.5 years, 53% were females. Overall, non-valvular cardiac, extra-cardiac and extra-vascular significant and non-significant incidental findings were documented in 97% of scans (87/90). Significant pathologies causing TAVI cancellation or postponement (category A) were documented in 8%. Significant findings affecting the TAVI procedure (category B) were found in 16% of patients. 

Conclusions: Pre-TAVI CTA detected non-valvular extra-vascular pathologies leading to procedure cancellation/postponement or procedure modification in 8% and 16%, respectively. Comprehensive CTA evaluation that acknowledges the importance of such findings is of major importance since it might alter the TAVI procedure or even render it inappropriate. 

 

October 2013
A. Finkelstein, E.Y. Birati, Y. Abramowitz, A. Steinvil, N. Sheinberg, S. Biner, S. Bazan, Y. Ben Gal, A. Halkin, Y. Arbel, E. Ben-Assa, E. Leshem-Rubinow, G. Keren and S. Banai
 Background: Transcatheter aortic valve implantation (TAVI) has recently become an alternative to surgical aortic valve replacement in selected patients with high operative risk.

Objectives: To investigate the 30 day clinical outcome of the first 300 consecutive patients treated with transfemoral TAVI at the Tel Aviv Medical Center.

Methods: The CoreValve was used in 250 patients and the Edwards-Sapien valve in 50 patients. The mean age of the patients was 83 ± 5.3 years (range 63–98 years) and the mean valve area 0.69 ± 0.18 cm2 (range 0.3–0.9 cm2); 62% were women.

Results: The procedural success rate was 100%, and 30 day follow-up was done in all the patients. The average Euro-score for the cohort was 26 ± 13 (range 1.5–67). Total in-hospital mortality and 30 day mortality were both 2.3% (7 patients). Sixty-seven patients (22%) underwent permanent pacemaker implantation after the TAVI procedure, mostly due to new onset of left bundle brunch block and prolonged PR interval or to high degree atrioventricular block. The rate of stroke was 1.7% (5 patients). Forty-one patients (13.7%) had vascular complications, of whom 9 (3%) were defined as major vascular complications (according to the VARC definition).

Conclusions: The 30 day clinical outcome in the first 300 consecutive TAVI patients in our center was favorable, with a mortality rate of 2.3% and low rates of stroke (1.7%) and major vascular complications (3%).

 

 







 VARC = Valve Academic Research Consortium


September 2013
A. L. Schwartz, Y. Topilsky, G. Uretzky, N. Nesher, Y. Ben-Gal, S. Biner, G. Keren and A. Kramer

Background: Stentless aortic bioprostheses were designed to provide improved hemodynamic performance and potentially better survival.

Objectives: To report the outcomes of patients after aortic valve replacement with the Freestyle® stentless bioprosthesis in the Tel Aviv Medical Center followed for ≤ 15 years.

Methods and Results: Between 1997 and 2011, 268 patients underwent primary aortic valve replacement with a Freestyle bioprosthesis, 211 (79%) of them in the sub-coronary position. Mean age, Charlson comorbidity index and Euro-score were 71.0 ± 9.2 years, 4.2 ± 1.5 and 10.2 ± 11 respectively, and 156 (58%) were male. Peak and mean trans-aortic gradient decreased significantly (75.0 ± 29.1 vs. 22.8 ± 9.6 mmHg, P < 0.0001; and 43.4 ± 17.2 vs. 12.1 ± 5.4 mmHg, P < 0.0001 respectively) in 3 months of follow-up. Mean overall follow-up was 4.9 ± 3.1 years and was complete in all patients. In-hospital mortality was 4.1% (n=11) but differed significantly between the first 100 patients operated before 2006 and the last 168 patients operated after January 2006 (8 vs. 3 patients, 8.0% vs. 1.8%, P = 0.01). Overall, 5 and 10 year survival rates were 85 ± 2.5% and 57.2 ± 5.7%, respectively. Five year survival was markedly improved in patients operated after January 2006 compared to those operated in the early years of the experience (92.3 ± 2.3% vs. 76.0 ± 4.4%, P = 0.0009). All the 21 octogenarians operated after January 2006 survived surgery, with excellent 5 year survival (85.1 ± 7.9%). Six patients required reoperation during follow-up: structural valve deterioration in five and endocarditis in one.

Conclusions: Aortic valve replacement with the Freestyle bioprosthesis provides good long-term hemodynamic and clinical outcomes, even in octogenarians. Valve calcification is the major (and rare) mode of valve deterioration leading to reoperation in these patients. 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel