• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


March 2013
A. Ber and D.S. Seidman
 Background: The insertion of a levonorgestrel-releasing intrauterine system (LNG-IUS) requires experience and is associated with a low failure rate.

Objectives: To assess the reasons given by gynecologists why they failed to insert a LNG-IUS.

Methods: We obtained data from the sole distributor in Israel that prospectively recorded these cases when contacted by gynecologists following an insertion failure.

Results: The mean rate of failed insertions was 0.95% (range 0.77–1.03%) for the 5 year study period 2006–2010. The most common reasons reported by gynecologists for LNG-IUS insertion failure were loss of sterility of the device, inability to insert the device due to a stenotic cervical canal, accidental removal of the device following a successful insertion due to hasty removal of the inserter or the use of blunt scissors, and removal of the newly inserted LNG-IUS following ultrasound evidence that it was misplaced.

Conclusions:  Gynecologists should be aware of the common pitfalls associated with insertion of an LNG-IUS. Several techniques that may aid in avoiding these mishaps are described.

July 2010
D.S. Seidman, A. Yeshaya, A. Ber, I. Amodai, I. Feinstein, I. Finkel, N. Gordon, N. Porat, D. Samuel, E. Shiran-Makler and I. Wolman

Background: Continuous use of combined oral contraceptives is currently attracting growing interest as a means of improving menstrual related symptoms and reducing the number of bleeding days.

Objectives: To evaluate bleeding patterns, menstrual symptoms and quality of life with an extended 84/7 oral contraceptive regimen versus 21/7 cycles.

Methods: In two consecutive run-in cycles, 30 µg ethinyl estradiol and 3 mg drospirenone tablets taken on days 1–21 were followed by a tablet-free period from days 22 to 28 of each cycle and then by two 84 day cycles of pill use with a 7 day tablet-free interval. The primary outcome was the total number of bleeding/spotting days. Secondary outcomes were severity of daily symptoms, general well-being determined by the PGWBI questionnaire, and overall treatment satisfaction.

Results: Of the 137 women invited to participate in the study 109 (aged 18–40 years) were enrolled. The number of bleeding days decreased by about one-third from a calculated 31.8 days of bleeding under a cyclic 21/7 regimen to an expected total of 21.8 days for the extended 84/7 regimen. The incidence of menorrhagia, intermenstrual bleeding, dysmenorrhea, abdominal bloating, breast tenderness, depressive moods and irritability – when compared at enrollment and at the end of the second extended study period – was significantly lower (P < 0.005) among women on the continuous pill regimen. The median (range) global PGWBI scores were not substantially different before and after the extended use cycles: 78.2 (39.1–96.4) and 77.3 (30.9–96.4), respectively. Body weight and skin condition also remained constant. At the completion of the study: 65.5% of the women were either highly satisfied (41.4%) or satisfied (24.1%) with the extended regimen.

Conclusions: The extended 84/7 regimen was found to be satisfactory for the majority of participants and was associated with a decrease in the number of bleeding days and an improvement in menstrual symptoms compared to 21/7 cycles.
 

 

 
 

 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel