Tamar Slobodov MD, Gergana Marincheva MD, Michael Rahkovich MD, Andrei Valdman MD, Yonatan Kogan MD, Avishag Laish-Farkash MD PhD

Background: Cardiac implantable electronic devices (CIEDs) with endocardial leads crossing the tricuspid valve can lead to or worsen tricuspid regurgitation (TR), causing substantial morbidity and mortality. Despite a recent randomized controlled study revealing a low short-term incidence of device-related TR (DRT) post-CIED implantation, uncertainties persist regarding the efficacy of intra-procedural 2-dimensional transthoracic echocardiography (2DTTE) in preventing long-term TR.

Objectives: To conduct a long-term follow-up study on patients with CIED implants based on a previous study conducted at our hospital.

Methods: In a retrospective study at Assuta Ashdod Medical Center (2018–2019), patients undergoing de-novo CIED implantation with (n=39, group 1) or without (n=51, group 2) intra-procedural 2DTTE were analyzed. Clinical, demographic, and long-term (> 1 year) echocardiographic data were collected and compared.

Results: The study included 90 patients (mean age 72.3 ± 11.0 years, 63% male, 23% ICD, 50% active leads, follow-up 32.8 ± 11 months). TR aggravation was found in 25% of patients (13 in group 1, 10 in group 2), with no statistical difference between groups. Multivariate analysis identified a history of atrial fibrillation (AF) as the sole significant factor in long-term TR deterioration (OR=3.44, 95%CI 1.13–10.43, P = 0.029). Other clinical, demographic, echocardiographic, and device-related factors did not significantly contribute to long-term DRT.

Conclusions: After one-year post-CIED implantation, the incidence of DRT significantly increases. Intra-procedural 2DTTE does not effectively reduce long-term DRT, suggesting that implantation-related mechanisms are less likely the primary cause. AF likely plays a major role in the pathogenesis of long-term TR in this subset post-CIED implantation.

Yana Kakzanov MD, Yamama Alsana, Tal Brosh-Nissimov MD, Emanuel Harari MD, Michael Rahkovich MD, Yonatan Kogan MD, Emma Shvets RN MA, Gergana Marincheva MD, Lubov Vasilenko MD, Avishag Laish-Farkash MD PhD

Background: Cardiac implantable electronic devices (CIEDs) are associated with risks of device-related infections (DRI) impacting major adverse outcomes. Staphylococcus aureus (SA) is a leading cause of early pocket infection and bacteremia. While studies in other surgical contexts have suggested that nasal mupirocin treatment and chlorhexidine skin washing may reduce colonization and infection risk, limited data exist for CIED interventions.

Objectives: To assess the impact of SA decolonization on DRI rates.

Methods: We conducted a retrospective, single-center observational study on consecutive patients undergoing CIED interventions (March 2020–March 2022). All patients received pre-procedure antibiotics and chlorhexidine skin washing. Starting in March 2021, additional pre-treatment with mupirocin for SA decolonization was administered. DRI rates within 6 months post-implantation were compared between patients treated according to guidelines (Group 1) and those receiving mupirocin in addition to the recommended guidelines (Group 2).

Results: The study comprised 276 patients (age 77 ± 10 years; 60% male). DRI occurred in five patients (1.8%);80% underwent cardiac resynchronization therapy procedures. In Group 1 (n=177), four patients (2.2%) experienced DRI 11–48 days post-procedure; three with pocket infection (two with negative cultures and one with local Pseudomonas) and one with methicillin-sensitive SA endocarditis necessitating device extraction. In Group 2 (n=99), only one patient (1%) had DRI (Strep. dysgalactiae endocarditis) 135 days post-procedure (P = NS).

Conclusions: The routine decolonization of SA with mupirocin, in addition to guideline-directed protocols, did not significantly affect DRI rates. Larger prospective studies are needed to evaluate the preventive role of routine SA decolonization in CIED procedures.

June 2024
Ehud Jacobzon MD, Avital Lifschitz RN, Danny Fink MD, Tal Hasin MD

Background: Left ventricular assist devices (LVAD) are a staple element in contemporary treatment of advanced heart failure. LVAD surgeries are mostly done in heart transplantations centers, as a destination therapy or as a bridge to heart transplantation.

Objectives: To describe our step-by-step experience in establishing and implementing a new LVAD program in a non-heart transplant center. To give insight to our short- and long-term results of our first 25 LVAD patients.

Methods: Preliminary steps included identifying the need for a new program and establishing the leading team. Next is defining protocols for pre-operative evaluation, operating room, post-operative management, and outpatient follow-up. The leading team needs to educate other relevant units in the hospital that will be involved in the care of these patients. It is essential to work in collaboration with a heart transplant center from the very beginning. Patient selection is of major importance especially in the early experience. Initially “low risk” patients should be enrolled.

Results: We describe our first 25 LVAD patients. Our first five patients all survived beyond 2 years, with no major complications. Overall, there was one operative death due to massive GI bleeding. There were four late deaths due to septic events.

Conclusions: Establishing a new LVAD program can be successful also with small- and medium-size programs. With careful and meticulous planning LVAD implantation can be extended to more centers thus offering an excellent solution for advanced heart failure patients.

Shelly Tartakover Matalon PhD, Noa Rabinowicz PhD, Or Carmi MD, Tali Zitman-Gal PhD, Liat Drucker PhD, Yair Levy MD

Background: Immunoglobulin G4-related disease (IgG4-RD) is a chronic, immune-mediated condition characterized by fibro-inflammatory lesions with lymphoplasmacytic infiltration. Diagnosis traditionally relies on histopathological findings, including the presence of IgG4+ plasma cells. However, due to challenges in biopsy accessibility, additional measures are needed to facilitate diagnosis.

Objectives: To identify additional parameters for characterizing IgG4-RD patients.

Methods: We compared several circulating factors between a cohort of patients with IgG4-RD disease seen at our hospital between 2017 and 2023 and healthy controls.

Results: Among 16 suspected patients, 13 were confirmed to have IgG4-RD, and 3 were classified as highly likely. Comparison with controls revealed differences in white blood cell count (WBC) (Folf change (FC) 1.46, P < 0.05), plasmablasts (FC 3.76, P< 0.05), plasmablasts CD38 (FC 1.43, P < 0.05), and CD27 (FC 0.66, P = 0.054), thus highlighting potential markers for IgG4-RD diagnosis. Treatments with steroids/rituximab tend to reduce plasmablast (FC 0.6) and IgG4 (FC 0.28) levels and to increase Gal-3 levels.

Conclusions: Levels of plasmablasts are a significant diagnostic feature in IgG4-RD. Healthy individuals have a lower level of plasmablasts. Elevated Gal-3 in serum of patients with IgG4-RD suggests a role in plasmablast activation. CD38/CD27 expression by plasmablasts emerges as a potential marker. Further research on a larger cohort is needed to confirm these findings.

May 2024
Rabea Haddad MD, Edo Birati MD, Hiba Zayyad MD, Nizar Andria MD, Eyal Nachum MD, Erez Kachel MD, Ibrahim Marai MD

Background: Cardiac implantable electronic devices (CIEDs) are increasingly being used; thus, there is an increasing need for transvenous lead extraction (TLE).

Objectives: To summarize our experience with TLE at single referral center in northern Israel.

Methods: The study included all patients who underwent TLE at our center between 2019 and 2022, regardless of the indication.

Results: The cohort included 50 patients. The mean age was 69 ± 10.36 years; 78% were males. A total of 99 electrodes were targeted. The mean number of electrodes was 1.96 (range 1–4) per patient. The time between lead implantation and extraction ranged between 1.1 and 34 years with an average of 8.14 ± 5.71 years (median of 7.5 years). Complete lead removal was achieved in 98% of patients and in 98.99% of leads. The complete procedural success rate as well as the clinical procedural success rate was 96%. The procedural failure rate was 4% (1 patient died 2 days after the index procedure and 1 patient remained with large portion of lead). The indication for TLE was infection in 78% of the cohort group. Powered mechanical sheaths were used in 36 patients (72%), laser sheaths in 27 (54%), and a combination of laser and mechanical sheaths in 16 (32%).

Conclusions: The clinical and procedural success rates of TLE, primarily for CEID-related infection, were high. A combination of laser and mechanical sheaths was needed in one-third of patients.

April 2024
Dante Antonelli MD, Vladimir Poletaev MD, Vidal Essebag MD, Alexander Feldman MD

Inappropriate implantable cardiac defibrillator (ICD) shock due to electromagnetic interference (EMI) induced by electrocautery is a well-known theoretical association but is rarely reported [1]. We report a case of EMI induced by electrocautery causing inappropriate ICD shock, underlining that, with the use of monopolar cautery, not only the location of the surgery but also electrodispersive pad (EDP) placement may be important to avoid EMI.

February 2024
Nadav Loebl MSc, Eytan Wirtheim MD, Leor Perl MD

Background: The field of artificial intelligence (AI) is poised to significantly influence the future of medicine. With the accumulation of vast databases and recent advancements in computer science methods, AI's capabilities have been demonstrated in numerous areas, from diagnosis and morbidity prediction to patient treatment. Establishing an AI research and development unit within a medical center offers multiple advantages, particularly in fostering research and tapping into the immediate potential of AI at the patient's bedside.

Objectives: To outline the steps taken to establish a center for AI and big data within an innovation center at a tertiary hospital in Israel.

Methods: We conducted a retrospective analysis of projects developed in the field of AI at the Artificial Intelligence Center at the Rabin Medical Center, examining trends, clinical domains, and the predominant sectors over a specific period.

Results: Between 2019 and 2023, data from 49 AI projects were gathered. A substantial and consistent growth in the number of projects was observed. Following the inauguration of the Artificial Intelligence Center we observed an increase of over 150% in the volume of activity. Dominant sectors included cardiology, gastroenterology, and anesthesia. Most projects (79.6%) were spearheaded by physicians, with the remainder by other hospital sectors. Approximately 59.2% of the projects were applied research. The remainder were research-based or a mix of both.

Conclusions: Developing technological projects based on in-hospital medical data, in collaboration with clinicians, is promising. We anticipate the establishment of more centers dedicated to medical innovation, particularly involving AI.

October 2023
Susana Mikhail Mustafa MD, Raneen Abu Shqara MD, Maya Frank Wolf MD, Oleg Shnaider MD, Sari Nahir Biderman RN MA, Limor Sharabi MA, Lior Lowenstein MD

Background: The French AmbUlatory Cesarean Section (FAUCS) technique was introduced to the Galilee Medical Center in September 2021. FAUCS was performed electively for interested women who meet the criteria.

Objectives: To evaluate the learning curve of senior surgeons performing FAUCS, the procedure short-term outcomes, and complications.

Methods: This retrospective study included 50 consecutive women who underwent FAUCS from September 2021 until March 2022 at our facility. Preoperative, intraoperative, postoperative, and demographic data were retrieved from patient electronic charts.

Results: The mean duration of surgery was 53.26 ± 11.62 minutes. This time decreased as the surgical team's experience increased: from a mean 58.26 ± 12.25 minutes for the first 15 procedures to a mean 51.17 ± 9.73 minutes for subsequent procedures. The mean visual analogue scale score for 24 hours was 1.08 ± 0.84 (on a 10-point scale). The rate of neonatal cord pH < 7.2 was 6%, and there were 11.3% cases of vacuum assisted fetal extraction. In total, 44% of the women were able to mobilize and urinate spontaneously by 4–6 hours. Complications included bladder injury (n=1), endometritis (n=1), and incisional hematoma (n=1). Overall, the maternal satisfaction rate was high; 94% of the women would recommend FAUCS to others.

Conclusions: FAUCS is a feasible procedure with a high satisfaction rate. Following the first 15 procedures performed by one surgical team, the operative time decreased considerably. Further randomized controlled studies are needed to compare this procedure to regular cesarean section and evaluate neonatal outcomes.

George Shallufi MD, Suhair Hanna MD, Asaad Khoury MD, Tarek Saadi MD, Anat Ilivitzki MD, Michal Gur MD, Lea Bentur MD, Ronen Bar-Yoseph MD

Common variable immunodeficiency (CVID) is a heterogeneous primary immune deficiency disorder characterized mainly by defective B lymphocyte differentiation, leading to hypogammaglobinemia and defective antibody production. It is often combined with cellular immune defects. A minority of patients present during childhood and adolescence. Infections are most often sinopulmonary but can affect any system. The noninfectious complications include progressive lung disease, autoimmunity, gastrointestinal inflammatory disease, liver disease, granulomatous disease, lymphoid hyperplasia and infiltrative disease, and the development of lymphoma and other cancers. In addition to recurrent infections and bronchiectasis, patients may develop chronic interstitial lung disease, granulomatous lung disease, lymphoma, and pulmonary hypertension.

August 2023
Michal M. Amitai MD, Nadin Kanaan MD, Shelly Soffer MD, Lee Alper, Noa Rozendorn MD, Daniel Jacob Harrington, Uri Kopylov MD, Adi Lahat MD, Doron Yablecovitch MD, Rami Eliakim MD, Shomron Ben-Horin MD, Eyal Klang MD

Background: Jejunal disease is associated with worse prognosis in Crohn's disease. The added value of diffusion weighted imaging for evaluating jejunal inflammation related to Crohn's Disease is scarce.

Objectives: To compare diffusion weighted imaging, video capsule endoscopy, and inflammatory biomarkers in the assessment of Crohn's disease involving the jejunum.

Methods: Crohn's disease patients in clinical remission were prospectively recruited and underwent magnetic resonance (MR)-enterography and video capsule endoscopy. C-reactive protein and fecal-calprotectin levels were obtained. MR-enterography images were evaluated for restricted diffusion, and apparent diffusion coefficient values were measured. The video capsule endoscopy-based Lewis score was calculated. Associations between diffusion weighted imaging, apparent diffusion coefficient, Lewis score, and inflammatory biomarkers were evaluated.

Results: The study included 51 patients, and 27/51 (52.9%) with video capsule endoscopies showed jejunal mucosal inflammation. Sensitivity and specificity of restricted diffusion for video capsule endoscopy mucosal inflammation were 59.3% and 37.5% for the first reader, and 66.7% and 37.5% for the second reader, respectively. Diffusion weighted imaging was not statistically associated with jejunal video capsule endoscopy inflammation (P = 0.813).

Conclusions: Diffusion weighted imaging was not an effective test for evaluation of jejunal inflammation as seen by video capsule endoscopy in patients with quiescent Crohn's disease.

June 2023
Tal Bechor Ariel MD, Ben Ariel MD, Yuni Lahav MD, Moshe Yana BSc, Michael Ben-Acon MD, Nechama Sharon MD

Background: Infants younger than 6 months of age are not eligible for coronavirus disease 2019 (COVID-19) vaccinations. Maternal variables during pregnancy and the postnatal period may affect the clinical and laboratory course of COVID-19 positive infants.

Objective: To assess the clinical manifestation and laboratory differences in infants with three maternal variables: breastfeeding, vaccinated, and co-illness.

Methods: We conducted a single-center retrospective cohort study of positive COVID-19 infants with three subgroups of maternal variables. The population included infants under 6 months of age hospitalized due to COVID-19. Data about clinical features, laboratory tests, and maternal information including vaccination status, breastfeeding status and maternal positive COVID-19 infection was gathered. All variables were compared among the three subgroups.

Results: Breastfed infants had shorter hospitalization period (mean 2.61 ± 1.378 days) compared to non-breastfed infants (mean 3.8 ± 1.549) (P = 0.051). COVID-19 infants of positive COVID-19 mothers had a higher absolute neutrophil count (mean 4.4 ± 3.8) compared to infants of COVID-19 negative mothers (mean 2.7 ± 2.4) (P = 0.042).

Conclusion: Breastfeeding was associated with shorter periods of hospitalization in COVID-19 positive infants. In addition, positive COVID-19 infants of mothers who were positive for COVID-19 are likely to have a higher absolute neutrophils count.

Majdi Halabi MD, Hagar Drimer-Shabtai MD, Inna Rosenfeld MD, Adi Sharabi-Nov MA MPH, Mussa Saad MD, Ibrahim Marai MD, Ziad Abuiznait MD, Ayelet Armon-Omer PhD, Zippi Regev-Avraham PhD, Zeev Israeli MD

Background: Implantable loop recorders (ILRs) are a central tool in the evaluation of unexplained syncope. These devices record and store electrocardiograms, both automatically and on patient-dependent activation. Therefore, obtaining optimal diagnostic results relies on a patient's comprehension and collaboration.

Objectives: To evaluate the effect of ethnic background and mother-tongue language on the diagnostic yield (DY) of ILRs.

Methods: Patients at two medical centers in Israel, who had ILRs as part of syncope workup were included. Inclusion criteria were age over 18 years and an ILR for at least one year (or less if the cause of syncope was detected). Patient demographics, ethnic background, and previous medical history were recorded. All findings from ILR recordings, activation mode (manual vs. automatic), and treatment decisions (none, ablation, device implantation) were collected.

Results: The study comprised 94 patients, 62 Jews (i.e., ethnic majority) and 32 non-Jews (i.e., ethnic minority). While baseline demographic characteristics, medical history, and drug therapy were similar in both groups, Jewish patients were significantly older at the time of device implantation: 64.3 ± 16.0 years of age vs. 50.6 ± 16.9, respectively; (P < 0.001). Arrhythmias recorded in both groups as well as treatment decisions and device activation mode were similar. Total follow-up time from device implantation was longer in the non-Jewish vs. the Jewish group (17.5 ± 12.2 vs. 24.0 ± 12.4 months, respectively; P < 0.017).

Conclusions: The DY of ILR implanted for unexplained syncope did not seem to be influenced by patient's mother-tongue language or ethnicity.

Dante Antonelli MD, Vladimir Poletaev MD, Alexander Feldman MD

Inappropriate shocks are a serious and still unresolved problem associated with implantable cardioverter defibrillators (ICDs) that have been associated with increased mortality and impairment of quality of life [1] despite advances in device safety. We report a case of electromagnetic interference (EMI) while showering that resulted in an inappropriate ICD discharge.

March 2023
Batya Wizman MD, Moti Haim MD, Ido Peles, Roi Westreich MD, Amjad Abu-Salman MD, Gal Tsaban MD MPH, Natalie Yasoor, Orit Barrett MD, Yuval Konstantino MD

Background: Existing cardiac disease contributes to poor outcome in patients with coronavirus disease 2019 (COVID-19). Little information exists regarding COVID-19 infection in patients with a cardiac implantable electronic device (CIED).

Objectives: To assess the association between CIEDs and severity of COVID-19 infection.

Methods: We performed a retrospective analysis including 13,000 patients > 18 years old with COVID-19 infection between January and December 2020. Patients with COVID-19 who had a permanent pacemaker or defibrillator were matched 1:4 based on age and sex followed by univariate and multivariate analyses. Baseline characteristics and clinical outcomes were assessed.

Results: Forty patients with CIED and 160 patients without CIED were included in the current analysis. Mean age was 72.6 ± 13 years, and approximately 50% were females. Majority of the patients in the study arm had a pacemaker (63%), whereas only 15 patients (37%) had a defibrillator. Patients with COVID-19 and CIED presented more often with atrial fibrillation, coronary artery disease, heart failure, hypertension, diabetes, and chronic kidney disease. They were more likely to be hospitalized in the intensive care unit (ICU) and required more ventilatory support (35% vs. 18.3%). Thirty-day mortality (22.5% vs. 13.8%) and 1-year mortality (25% vs. 15%) were higher among patients with COVID-19 and CIED.

Conclusions: Patients with COVID-19 and CIED had a significantly higher prevalence of co-morbidities that were associated with increased mortality. Although,CIED by itself was not found as an independent risk factor for morbidity and mortality, it may serve as a warning for severe illness with COVID-19.

September 2022
Alex Sorkin MD, Avishai M. Tsur MD MHA, Roy Nadler MD, Ariel Hirschhorn MD, Ezri Tarazi BDes, Jacob Chen MD MHA, Noam Fink MD, Guy Avital MD, Shaul Gelikas MD MBA, and Avi Benov MD MHA

Background: The Israeli Defense Forces-Medical Corps (IDF-MC) focuses on reducing preventable death by improving prehospital trauma care. High quality documentation of care can serve casualty care and to improve future care. Currently, paper casualty cards are used for documentation. Incomplete data acquisition and inadequate data handover are common. To resolve these deficits, the IDF-MC launched the BladeShield 101 project.

Objectives: To assess the quality of casualty care data acquired by comparing standard paper casualty cards with the BladeShield 101.

Methods: The BladeShield 101 system consists of three components: a patient unit that records vital signs and medical care provided, a medical sensor that transmits to the patient unit, and a ruggedized mobile device that allows providers to access and document information. We compared all trauma registries of casualties treated between September 2019 and June 2020.

Results: The system was applied during the study period on 24 patients. All data were transferred to the military trauma registry within one day, compared to 72% (141/194) with a paper casualty card (P < 0.01). Information regarding treatment time was available in 100% vs. 43% (P < 0.01) of cases and 98% vs. 67% (P < 0.01) of treatments provided were documented comparing BladeShield 101 with paper cards, respectively.

Conclusions: Using an autonomous system to record, view, deliver, and store casualty information may resolve most current information flow deficits. This solution will ultimately significantly improve individual patient care and systematic learning and development processes.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel