Background: Trans-aortic pressure gradient in patients with aortic stenosis and left ventricular systolic dysfunction is typically low but occasionally high.
Objectives: To examine the distribution of trans-aortic PG in patients with severe AS and severe LV dysfunction and compare the clinical and echocardiographic characteristics and outcome of patients with high versus low PG.
Methods: Using the echocardiographic laboratory database at our institution, 72 patients with severe AS (aortic valve area ≤ 1.0 cm2) and severe LV dysfunction (LV ejection fraction ≤ 30%) were identified. The characteristics and outcome of these patients were compared.
Results: PG was high (mean PG ≥ 35 mmHg) in 32 patients (44.4%) and low (< 35 mmHg) in 40 (55.6%). Aortic valve area was slightly smaller in patients with high PG (0.63 ± 0.15 vs. 0.75 ± 0.16 cm2 in patients with low PG, P = 0.003), and LV ejection fraction was slightly higher in patients with high PG (26 ± 5 vs. 22 ± 5% in patients with low PG, P = 0.005). During a median follow-up period of 9 months 14 patients (19%) underwent aortic valve replacement and 46 patients (64%) died. Aortic valve replacement was associated with lower mortality (age and gender-adjusted hazard ratio 0.19, 95% confidence interval 0.05–0.82), whereas trans-aortic PG was not (P = 0.41).
Conclusions: A large proportion of patients with severe AS have relatively high trans-aortic PG despite severe LV dysfunction, a finding partially related to more severe AS and better LV function. Trans-aortic PG is not related to outcome in these patients.