• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sun, 24.11.24

Search results


August 2023
Michal M. Amitai MD, Nadin Kanaan MD, Shelly Soffer MD, Lee Alper, Noa Rozendorn MD, Daniel Jacob Harrington, Uri Kopylov MD, Adi Lahat MD, Doron Yablecovitch MD, Rami Eliakim MD, Shomron Ben-Horin MD, Eyal Klang MD

Background: Jejunal disease is associated with worse prognosis in Crohn's disease. The added value of diffusion weighted imaging for evaluating jejunal inflammation related to Crohn's Disease is scarce.

Objectives: To compare diffusion weighted imaging, video capsule endoscopy, and inflammatory biomarkers in the assessment of Crohn's disease involving the jejunum.

Methods: Crohn's disease patients in clinical remission were prospectively recruited and underwent magnetic resonance (MR)-enterography and video capsule endoscopy. C-reactive protein and fecal-calprotectin levels were obtained. MR-enterography images were evaluated for restricted diffusion, and apparent diffusion coefficient values were measured. The video capsule endoscopy-based Lewis score was calculated. Associations between diffusion weighted imaging, apparent diffusion coefficient, Lewis score, and inflammatory biomarkers were evaluated.

Results: The study included 51 patients, and 27/51 (52.9%) with video capsule endoscopies showed jejunal mucosal inflammation. Sensitivity and specificity of restricted diffusion for video capsule endoscopy mucosal inflammation were 59.3% and 37.5% for the first reader, and 66.7% and 37.5% for the second reader, respectively. Diffusion weighted imaging was not statistically associated with jejunal video capsule endoscopy inflammation (P = 0.813).

Conclusions: Diffusion weighted imaging was not an effective test for evaluation of jejunal inflammation as seen by video capsule endoscopy in patients with quiescent Crohn's disease.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel