• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Wed, 17.07.24

Search results


May 2024
Rabea Haddad MD, Edo Birati MD, Hiba Zayyad MD, Nizar Andria MD, Eyal Nachum MD, Erez Kachel MD, Ibrahim Marai MD

Background: Cardiac implantable electronic devices (CIEDs) are increasingly being used; thus, there is an increasing need for transvenous lead extraction (TLE).

Objectives: To summarize our experience with TLE at single referral center in northern Israel.

Methods: The study included all patients who underwent TLE at our center between 2019 and 2022, regardless of the indication.

Results: The cohort included 50 patients. The mean age was 69 ± 10.36 years; 78% were males. A total of 99 electrodes were targeted. The mean number of electrodes was 1.96 (range 1–4) per patient. The time between lead implantation and extraction ranged between 1.1 and 34 years with an average of 8.14 ± 5.71 years (median of 7.5 years). Complete lead removal was achieved in 98% of patients and in 98.99% of leads. The complete procedural success rate as well as the clinical procedural success rate was 96%. The procedural failure rate was 4% (1 patient died 2 days after the index procedure and 1 patient remained with large portion of lead). The indication for TLE was infection in 78% of the cohort group. Powered mechanical sheaths were used in 36 patients (72%), laser sheaths in 27 (54%), and a combination of laser and mechanical sheaths in 16 (32%).

Conclusions: The clinical and procedural success rates of TLE, primarily for CEID-related infection, were high. A combination of laser and mechanical sheaths was needed in one-third of patients.

Jonathan Eisenberger BSc, Shmuel Somer BSc, Eyal Nachum MD, Eilon Ram MD, Jacob Lavee MD, Leonid Sternik MD, Jeffrey Morgan MD

Background: Long-term support with a HeartMate 3 (HM3) left ventricular assist device (LVAD) has improved outcomes of patients with end-stage heart failure. However, there is a paucity of data on the outcomes of patients who underwent concomitant cardiac surgical procedure (CCSP) during HM3-LVAD implantation.

Objectives: To assess our single-center experience with patients who underwent CCSP during the implantation of an HM3-LVAD.

Methods: From December 2016 until April 2022, 131 adult patients underwent HM3-LVAD implantation. A total of 23 patients underwent CCSP during the HM3-LVAD implantation+CCSP, and 108 underwent only HM3-LVAD implantation (HM3-only).

Results: The median age was 59 ± 11 years (range 54-67), 82% (n=108) were male, and 76% (n=100) were implanted as a bridge-to-transplant. The concomitant procedures performed during the implantation included 8 aortic valve repairs/replacements, 14 tricuspid valve repairs, 4 patent foramen ovales or atrial septal defect closures, and 3 other cardiac procedures. The mean cardiopulmonary bypass time was 113 ± 58 minutes for the HM3-only group and 155 ± 47 minutes for the HM3+CCSP group (P = 0.007). The mortality rates at 30 days, 6 months, and 12 months post-implantation were 2 (9%), 5 (22%), and 6 (26%) respectively for the HM3+CCSP group, and 7 (6%), 18 (17%), and 30 (28%) for the HM3-only group (P = 0.658, 0.554, and 1.000).

Conclusions: Our experience demonstrated no significant difference in the 30-day, 6-month, and 12-month mortality rates for patients who underwent a CCSP during HM3-LVAD implantation compared to patients who did not undergo CCSP during HM3-LVAD implantation.

November 2023
Jonathan Eisenberger BSc, Shmuel Somer BSc, Eilon Ram MD, Eyal Nachum MD, Jonathan Frogal MD, Shany Levin MA, Jacob Lavee MD, Leonid Sternik MD, Jeffrey Morgan MD

Background: Unfractionated heparin is the preferred anticoagulant used during open heart surgeries, including left ventricular assist device (LVAD) implantation. In cases in which patients are heparin-induced thrombocytopenia positive (HIT+), the accepted practice has been to substitute heparin with bivalirudin. This practice may be associated with significant bleeding and adverse outcomes.

Objectives: To review our experience with HIT+ patients who were heparin-induced thrombocytopenia with thrombosis negative (HITT-) and who underwent HeartMate 3 LVAD implantation using heparin intraoperatively rather than bivalirudin.

Methods: From 2016 to 2022, 144 adult patients were implanted with HeartMate 3 LVAD at our center. Among them, 7 were detected as HIT+ but HITT- and therefore were prescribed intraoperatively with heparin and treated pre- and postoperatively with bivalirudin. We reviewed the preoperative, intraoperative, and postoperative characteristics as well as short-term mortality and the complication rates of these HIT+ patients.

Results: The median age of our cohort was 56 years (51–60), 71% were male (n=5), all were INTERMACS Level 1, and most were bridged to transplant (n=6, 86%). The 30-day mortality rate post-implantation was 0%. The average 24-hour chest drain postoperative output was 1502.86 ± 931.34 ml. There were no intraoperative pump thromboses, perioperative thromboses, cerebrovascular accidents, or gastrointestinal bleeding within the first 24 hours postoperative. One patient required a revision due to bleeding.

Conclusions: Intraoperative unfractionated heparin may be administered to patients who are HIT+ and HITT- while undergoing LVAD implantation. However, further investigation is required.

September 2018
Yael Peled MD, Dov Freimark MD, Yedael Har-Zahav MD, Eyal Nachum MD, Alexander Kogan MD, Yigal Kassif MD and Jacob Lavee MD

Background: Heart transplantation (HT) is the treatment of choice for patients with end-stage heart failure. The HT unit at the Sheba Medical Center is the largest of its kind in Israel.

Objectives: To evaluate the experience of HT at a single center, assess trends over 3 decades, and correlate with worldwide data.

Methods: Between 1990 and 2017, we reviewed all 285  adult HT patients. Patients were grouped by year of HT: 1990–1999 (decade 1), 2000–2009 (decade 2), and 2010–2017 (decade 3).

Results: The percentage of women undergoing HT has increased and etiology has shifted from ischemic to non-ischemic cardiomyopathy (10% vs. 25%, P = 0.033; 70% vs. 40% ischemic, for decades 1 vs. 3, respectively). Implantation of left ventricular assist device as a bridge to HT has increased. Metabolic profile has improved over the years with lower low-density lipoprotein, diabetes, and hypertension after HT (101 mg/dl, 27%, and 41% at decade 3, respectively). There has been a prominent change in immunosuppressive treatments, currently more than 90% are treated with tacrolimus, compared with 2.7% and 30.9% in decades 1 and 2, respectively (P < 0.001). Cardiac allograft vasculopathy (CAV) rates have declined significantly (47% vs. 17.5% for decades 1 and 2, P < 0.001) as have the combined endpoint of CAV/death. Similarly, the current incidence of acute rejections is significantly lower.

Conclusions: Our analysis of over 25 years of a single-center experience with HT shows encouraging improved results, which are in line with worldwide standards and experience.

September 2017
Ido-David Dechtman MD, Chagai Grossman MD, Yael Shinar MD, Rinat Cohen MD, Eyal Nachum MD, Ehud Raanani MD, Avi Livneh MD and Ilan Ben-Zvi MD

Background: Postpericardiotomy syndrome (PPS) is characterized by pleuro-pericardial inflammation, which occurs in patients undergoing surgical procedures involving the pleura, pericardium, or both. The syndrome is considered to be immune mediated. However, its pathogenesis is not fully understood. It has previously been demonstrated that the Mediterranean Fever (MEFV) gene, which is associated with familial Mediterranean fever (FMF), has a role in the activation and expression of several inflammatory diseases.

Objectives: To investigate whether carriage of the MEFV mutation may precipitate PPS or affect its phenotype.

Methods: The study population included 45 patients who underwent cardiac surgery and developed PPS. The control group was comprised of 41 patients who did not develop PPS. Clinical and demographic data was collected. The severity of PPS was evaluated. Genetic analysis to determine the carriage of one the three most common MEFV gene mutations (M694V, V726A, E148Q) was performed. The carriage rate of MEFV mutations in patients with and without PPS was compared. Association between MEFV mutation carriage and severity of PPS was evaluated. 

Results: The rate of mutation carriage in the MEFV gene was similar in patients with and without PPS (15.6% in the study groups vs. 29.3% in the control group, P = 0.1937). The rate of mutation carriage in the MEFV gene was significantly lower among patients with severe PPS as compared to patients with mild-moderate PPS (4.8% vs. 25%, P < 0.05).

Conclusions: Carriage of mutations in the MEFV gene is not associated with development of PPS; however, it may affect PPS severity.

 

February 2016
Amjad Shalabi MD, Ehud Raanani MD, Amihai Shinfeld MD, Rafael Kuperstein MD, Alexander Kogan MD, Alexander Lipey MD, Eyal Nachum MD and Dan Spiegelstein MD

Background: Prolonged life expectancy has increased the number of elderly high risk patients referred for surgical aortic valve replacement (AVR). These referred high risk patients may benefit from sutureless bioprosthesis procedures which reduce mortality and morbidity.

Objectives: To present our initial experience with sutureless aortic bioprotheses, including clinical and echocardiographic results, in elderly high risk patients referred for AVR. 

Methods: Forty patients (15 males, mean age 78 ± 7 years) with symptomatic severe aortic stenosis underwent AVR with the 3F Enable™ or Perceval™ sutureless bioprosthesis during the period December 2012 to May 2014. Mean logistic EuroScore was 10 ± 3%. Echocardiography was performed preoperatively, intraoperatively, at discharge and at follow-up.

Results: There was no in-hospital mortality. Nine patients (22%) underwent minimally invasive AVR via a right anterior mini-thoracotomy and one patient via a J-incision. Four patients underwent concomitant coronary aortic bypass graft, two needed intraoperative repositioning of the valve, one underwent valve exchange due to inappropriate sizing, three (7.5%) had a perioperative stroke with complete resolution of neurologic symptoms, and one patient (2.5%) required permanent pacemaker implantation due to complete atrioventricular block. Mean preoperative and postoperative gradients were 44 ± 14 and 13 ± 5 mmHg, respectively. At follow-up, 82% of patients were in New York Heart Association functional class I and II.

Conclusions: Sutureless AVR can be used safely in elderly high risk patients with relatively low morbidity and mortality. The device can be safely implanted via a minimally invasive incision. Mid-term hemodynamic results are satisfactory, demonstrating significant clinical improvement.

 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel