• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 22.11.24

Search results


August 2021
Uri Barak MD, Dimitri Sheinis MD, Eliezer Sidon MD, Shai Shemesh MD, Amir Amitai MD, and Nissim Ohana MD

Background: Cervical spinal surgery is considered safe and effective. One of the few specific complications of this procedure is C5 nerve root palsy. Expressed primarily by deltoid muscle and biceps brachii weakness, it is rare and has been related to nerve root traction or to ischemic spinal cord damage.

Objectives: To determine the clinical and epidemiological traits of C5 palsy. To determine whether C5 palsy occurs predominantly in one specific surgical approach compared to others.

Methods: A retrospective study of patients who underwent cervical spine surgery at our medical center during a consecutive 8-year period was conducted. The patient data were analyzed for demographics, diagnosis, and surgery type and approach, as well as for complications, with emphasis on the C5 nerve root palsy.

Results: The study group was comprised of 124 patients. Seven (5.6%) developed a C5 palsy following surgery. Interventions were either by anterior, by posterior or by a combined approach. Seven patients developed this complication. All of whom had myelopathy and were older males. A combined anteroposterior (5 patients) and posterior access (2 patients) were the only approaches that were associated with the C5 palsy. None of the patients who were operated via an anterior approach did develop this sequel.

Conclusions: The incidence of the C5 root palsy in our cohort reached 5.6%. Interventions performed through a combined anterior-posterior access in older myelopathic males, may carry the highest risk for this complication

August 2019
Tal Frenkel Rutenberg MD, Yuval Baruch MD, Nissim Ohana MD, Hanna Bernstine MD, Amir Amitai MD, Nir Cohen MD, Liran Domachevsky MD and Shai Shemesh MD

Background: Implant-related spinal infections are a surgical complication associated with high morbidity. Due to infection, hardware removal may be necessary, which could lead to pseudarthrosis and the loss of stability and alignment.

Objectives: To evaluate the accuracy and diagnostic value of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in the workup of patients with suspected implant-related infections of the spine and to assess the clinical impact of PET/CT results on the management of these infections.

Methods: The study included nine consecutive patients with a history of spinal surgery who underwent PET/CT for evaluation of suspected spinal implant related infection. All imaging studies were performed between January 2011 and December 2013. All 18F-FDG PET/CT scans were performed on an 8 slice PET/CT following an 18F-FDG injection. Images were scored both visually and semi-quantitatively by a radiology expert. Results were compared to additional imaging studies when available, which were correlated to clinical and bacteriological findings allowing calculation of sensitivity, specificity and accuracy.

Results: Among the patients, five experienced hardware-related spinal infection. 18F-FDG PET/CT sensitivity was 80%, specificity 100%, and accuracy 88.9%. One scan produced a false negative; however, a second PET/CT scan revealed an infection.

Conclusions: PET/CT was found to be valuable for the diagnosis of postoperative hardware-related spinal infection, especially when other imaging modalities were uninformative or inconclusive. As such, PET/CT could be useful for management of infection treatment.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel