Dan Levin, Salim Adawi MD, David A Halon MBChB, Avinoam Shiran MD, Ihab Asmer, Ronen Rubinshtein MD and Ronen Jaffe MD
Background: Radial artery occlusion (RAO) may occur following transradial catheterization, precluding future use of the vessel for vascular access or as a coronary bypass graft. Recanalization of RAO may occur; however, long-term radial artery patency when revascularization is more likely to be required has not been investigated. Transradial catheterization is usually performed via 5-Fr or 6-Fr catheters. Insertion of 7-Fr sheaths into the radial artery enables complex coronary interventions but may increase the risk of RAO.
Objective: To assess the long-term radial artery patency following transradial catheterization via 7-Fr sheaths.
Methods: Antegrade radial artery blood flow was assessed by duplex-ultrasound in 43 patients who had undergone transradial catheterization via a 7-Fr sheath.
Results: All patients had received intravenous unfractionated heparin with a mean activated clotting time (ACT) of 247 ± 56 seconds. Twenty-four patients (56%) had received a glycoprotein IIbIIIa inhibitor and no vascular site complications had occurred. Mean time interval from catheterization to duplex-ultrasound was 507 ± 317 days. Asymptomatic RAO was documented in 8 subjects (19%). Reduced body weight was the only significant univariate predictor of RAO (78 ± 11 vs. 89 ± 13 kg, P = 0.031). In a bivariate model using receiver operator characteristic (ROC) curves, the combination of lower weight and shorter ACT offered best prediction of RAO (area under the ROC curve 0.813).
Conclusions: Asymptomatic RAO was found at late follow-up in approximately 1 of 5 patients undergoing transradial catheterization via a 7-Fr sheath and was associated with lower body weight and shorter ACT.